81240D
1.INSPECT NO. 2 ROOM LIGHT ASSEMBLY
| *a | Component without harness connected
(No. 2 Room Light Assembly) |
| *b | Ground |
Check the light operation.
Apply battery voltage to the terminals and check that the light comes on.
| Measurement Connection | Switch Condition | Specified Condition |
|---|---|---|
| Battery positive (+) - 2 (+)
Battery negative (-) - Ground |
OFF | Light not come on |
| Battery positive (+) - 2 (+)
Battery negative (-) - 1 (DR) |
OFF | Light not come on |
| Battery positive (+) - 2 (+)
Battery negative (-) - Ground |
ON | Light come on |
| Battery positive (+) - 2 (+)
Battery negative (-) - 1 (DR) |
DOOR | Light come on |
If the result is not as specified, replace the No. 2 room light assembly.