This circuit provides power to the combination meter assembly.
Inspect the fuses for circuits related to this system before performing the following procedure.
| *a | Front view of wire harness connector
(to Combination Meter Assembly) |
Disconnect the E34 combination meter assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E34-39 (IG) - Body ground | Ignition switch ON | 11 to 14 V |
| E34-40 (+B) - Body ground | Always | 11 to 14 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E34-16 (E) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG