Home › Vehicle Interior › HEATING / AIR CONDITIONING › REFRIGERANT › 2011.11–2015.08
RM19Y0E _58 Vehicle Interior _003013 HEATING / AIR CONDITIONING _0015225 REFRIGERANT G

HEATING / AIR CONDITIONING  REFRIGERANT  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 1.INSPECT REFRIGERANT VOLUME

E231775
1.177,1.063 1.635,0.396 true 1.042,1.063 1.25,1.292 0.208,0.229 10 *1
*1 Sight Glass


a.

Check the sight glass on No. 1 liquid tube.

Test conditions:

·

Engine running at 1500 rpm.

·

Blower speed control switch at HI.

·

Turn cooler control switch ON (w/ Heater).

·

A/C volume switch turned to MAX.

·

All doors fully open.


Item Symptom Amount of Refrigerant Corrective Procedure
1 Bubbles visible Insufficient* (1) Check for gas leakage and repair if necessary
(2) Add refrigerant until bubbles disappear
2 No bubbles visible Empty, insufficient or excessive Refer to items 3 and 4
3 No temperature difference between compressor inlet and outlet Empty or nearly empty (1) Check for gas leakage with halogen leak detector and repair if necessary
(2) Add refrigerant until bubbles disappear
4 Considerable temperature difference between compressor inlet and outlet Correct or much Refer to items 5 and 6
5 Immediately after A/C turned off, refrigerant becomes clear Excessive (1) Drain or discharge refrigerant
(2) Bleed air and charge proper amount of purified refrigerant
6 Immediately after A/C turned off, refrigerant foams and then becomes clear Correct -

HINT:

*: If the ambient temperature is higher than usual but cooling is sufficient, bubbles in the sight glass are permissible.



Hide 2. CHECK REFRIGERANT PRESSURE USING MANIFOLD GAUGE SET

a.

This is a method to identify trouble areas by using a manifold gauge set. Read the manifold gauge pressure under the following conditions.

Test conditions:

·

Engine warm.

·

All doors fully open.

·

Turn cooler control switch ON (w/ Heater).

·

A/C volume switch turned to MAX.

·

Blower speed control switch at HI.

·

Engine running at 1500 rpm.

·

Air temperature at air inlet 30 to 35°C (86 to 95°F).


i.
E050573

When the refrigerant volume is correct, the gauge reading indicates as follows:

Gauge Reading:
Pressure Side Specified Condition
Low 0.15 to 0.25 MPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi)
High 1.37 to 1.57 MPa (14 to 16 kgf/cm2, 199 to 228 psi)


HINT:

Pressure varies in accordance with certain conditions (outside air temperature, sunlight and wind).



ii.

When there is moisture in the refrigeration system:

I022117E35
0.031,0.031 2.51,0.406 2.479,0.375 10 Condition: Air conditioning system periodically cools and then fails to cool.

Symptom Probable Cause Diagnosis Corrective Action
During operation, pressure on low pressure side cycles between normal and vacuum Moisture in refrigeration system freezes at expansion valve orifice, causing temporary interruption of cycle
However, when melted, returns to normal condition
·

Receiver dryer oversaturated

·

Moisture in refrigeration system freezes at expansion valve orifice and blocks refrigerant circulation


1.

Replace receiver dryer

2.

Remove moisture from cycle by repeatedly evacuating air

3.

Charge appropriate volume of new refrigerant




iii.

When cooling is insufficient:

I022118E18
0.073,0.031 4.792,0.302 4.719,0.271 10 Condition: Air conditioning system does not function effectively.

Symptom Probable Cause Diagnosis Corrective Action
·

Pressure low on both low and high pressure sides

·

Bubbles are seen through sight glass continuously

·

Cooling performance insufficient


Gas leakage from refrigeration system
·

Insufficient refrigerant

·

Refrigerant leakage


1.

Check for gas leakage using halogen leak detector, and repair if necessary

2.

Charge appropriate volume of new refrigerant

3.

If indicated pressure value close to 0 when connected to gauge, create vacuum after inspecting and repairing location of leakage




iv.

When the circulation of the refrigerant is poor:

I022119E19
0.042,0.042 4.771,0.271 4.729,0.229 10 Condition: Air conditioning system does not function effectively.

Symptom Probable Cause Diagnosis Corrective Action
·

Pressure low on both low and high pressure sides

·

Frost exists on piping from condenser to A/C unit


Refrigerant flow obstructed by dirt in condenser Condenser clogged Replace condenser


v.

When the refrigerant does not circulate:

I022120E18
0.031,0.031 4.875,0.198 4.844,0.167 10 Condition: Air conditioning system does not function or functions intermittently.

Symptom Probable Cause Diagnosis Corrective Action
·

Vacuum indicated on low pressure side, and extremely low pressure indicated on high pressure side

·

Frost or condensation seen on piping on both sides of condenser or expansion valve


·

Refrigerant flow obstructed by moisture or dirt in refrigeration system

·

Refrigerant flow obstructed by gas leakage from expansion valve


Refrigerant does not circulate
1.

Check expansion valve

2.

Clean expansion valve with compressed air

3.

Replace condenser

4.

Evacuate air and then charge appropriate volume of new refrigerant

5.

For gas leakage from expansion valve, replace expansion valve




vi.

When the refrigerant is overcharged or cooling of condenser is insufficient:

I022121E19
0.052,0.042 4.917,0.281 4.865,0.24 10 Condition: Air conditioning system does not function effectively.

Symptom Probable Cause Diagnosis Corrective Action
·

Pressure extremely high on both sides

·

No air bubbles are seen through sight glass even when engine rpm lowers


·

Excessive refrigerant

·

Cooling performance of condenser insufficient


·

Excessive refrigerant

·

Cooling performance of condenser insufficient


1.

Clean condenser fins

2.

Check condenser fan motor operation by switching A/C ON

3.

If 1 and 2 normal, check amount of refrigerant and charge appropriate volume of refrigerant




vii.

When there is air in the refrigeration system:

I022122E20
0.042,0.052 4.094,0.271 4.052,0.219 10 Condition: Air conditioning system does not function. 4.604,0.25 7.135,0.99 2.531,0.74 10 NOTE: These gauge indications occur when the refrigeration system opens and the refrigerant is supplied without performing vacuum purging.

Symptom Probable Cause Diagnosis Corrective Action
·

Pressure extremely high on both low and high pressure sides

·

Low pressure piping too hot to touch

·

Bubbles can be seen through sight glass


Air in refrigeration system
·

Air in refrigeration system

·

Insufficient vacuum purging


1.

Check whether compressor oil dirty or insufficient

2.

Evacuate air and charge new refrigerant




viii.

When the expansion valve malfunctions:

I022123E16
0.042,0.042 4.906,0.281 4.865,0.24 10 Condition: Air conditioning system does not function effectively.

Symptom Probable Cause Diagnosis Corrective Action
·

Pressure extremely high on both low and high pressure sides

·

Frost or condensation on piping on low pressure side


Expansion valve malfunction
·

Excessive refrigerant in low pressure piping

·

Expansion valve opening too wide


Replace expansion valve


ix.

When the compressor is defective:

I022124E14
0.052,0.031 4.115,0.26 4.063,0.229 10 Condition: Air conditioning system does not function.

Symptom Probable Cause Diagnosis Corrective Action
·

Pressure extremely high on both low and high pressure sides

·

Pressure extremely low on high pressure side


Internal leakage in compressor
·

Compression failure of compressor

·

Leakage from damaged valve or broken sliding parts in compressor


Repair or replace compressor



Hide 3.INSPECT IDLING SPEED

a.

Warm up the engine.


b.

Inspect idling speed when these conditions are established.

Standard:
for M/T:
Condition Idling Speed
A/C volume switch off
A/C switch off
750 rpm
A/C volume switch turned to MAX 800 to 900 rpm


Standard:
for A/T:
Condition Idling Speed
A/C volume switch off
A/C switch off
750 rpm
A/C volume switch turned to MAX 850 to 950 rpm