Use the same procedure for the LHD and RHD vehicles.
The procedure listed below is for the RHD vehicle.
87138C
1.INSPECT BLOWER RESISTOR
| *a | Component without harness connected
(Blower Resistor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1(L) - 4(+) | Always | 2.81 to 3.23 Ω |
| 3(M&M1) - 4(+) | Always | 1.79 to 2.05 Ω |
| 2(M2) - 4(+) | Always | 0.76 to 0.88 Ω |
If the result is not as specified, replace the blower resistor.