HEATING / AIR CONDITIONING  REFRIGERANT  REPLACEMENT  


CAUTION / NOTICE / HINT

NOTICE:

When recharging refrigerant, collect the refrigerant remaining in the system, and then recharge and seal the refrigerant as described below. Do not overcharge.


PROCEDURE

Hide 1.RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM

a.

Start the engine.


b.

Turn the cooler control switch on (w/ Heater).


c.

Turn the A/C volume switch to MAX


d.

Turn the blower switch on.


e.

Operate the cooler compressor with an engine speed of approximately 1000 rpm for 5 to 6 minutes to circulate the refrigerant and collect the remaining compressor oil from each component, in the cooler compressor.


f.

Stop the engine.


g.
E318710C01
1.51,0.844 2.208,0.438 true 1.156,1.813 1.958,1.625 true 2.26,0.292 2.573,0.448 0.313,0.156 10 false *1 0.938,1.76 1.25,1.917 0.313,0.156 10 false *2
*1 Low Pressure Service Valve
*2 High Pressure Service Valve


Remove the caps from the service valves on the refrigerant line.


h.

Connect the refrigerant recovery unit.


i.

Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.

HINT:

Use the refrigerant recovery unit in accordance with the manufacturer's instruction manual.



Hide 2.CHARGE REFRIGERANT

I100449E13
0.438,2.885 3.396,3.208 2.958,0.323 10 false Check and fix connecting portion 1.198,3.875 3.615,5.135 2.417,1.26 10 false Gauge indicates abnormal pressure 3.771,0.438 6.677,0.76 2.906,0.323 10 false Start evacuation 3.75,2.094 6.479,2.396 2.729,0.302 10 false Suspend evacuation 3.781,3.688 6.563,4.021 2.781,0.333 10 false Check airtightness 3.781,5.344 6.542,5.646 2.76,0.302 10 false Charge refrigerant 3.76,6.979 6.604,7.323 2.844,0.344 10 false Check for gas leakage 5.323,4.083 7.031,5.083 1.708,1 10 false Gauge indicates normal pressure 5.271,0.833 7.156,1.927 1.885,1.094 10 false Evacuate until the pressure is 0.1 MPa (750 mmHg, 30 in. Hg) 5.281,2.458 7.115,3.531 1.833,1.073 10 false Leave to stand for 5 minutes (Check that the pressure has not changed after 5 minutes.)

HINT:

Charge refrigerant in accordance with the equipment manual.


a.

Perform vacuum purging using a vacuum pump.


b.

Charge refrigerant HFC-134a (R134a).

SST
09985-20010  (09985-02010, 09985-02050, 09985-02060, 09985-02070, 09985-02080, 09985-02090, 09985-02110, 09985-02130, 09985-02140, 09985-02150)

Standard:
Spec Amount of Refrigerant
w/o Rear Air Conditioning Unit 350 to 410 g (12.3 to 14.5 oz)
w/ Rear Air Conditioning Unit 470 to 530 g (16.6 to 18.7 oz)
w/ Rear Air Conditioning Unit
(for Tropic)
520 to 580 g (18.3 to 20.5 oz)


NOTICE:

Do not start the engine before charging it with refrigerant as the cooler compressor does not work properly without sufficient refrigerant. This could cause the compressor to overheat.


HINT:
·

The relationship between the refrigerant charge amount and the pressure is as follows.

I103968E05
5.156,1.146 7.031,1.771 1.875,0.625 10 false Appropriate median amount of refrigerant gas 1.333,0.719 3.115,1.052 1.781,0.333 10 false Refrigerant charge amount 0.052,0.698 1.063,1.156 1.01,0.458 10 false High Pressure 2.375,2.354 3.281,2.594 0.906,0.24 10 false Low charge 3.406,2.26 3.927,2.781 0.521,0.521 10 false Correct amount 4.5,2.26 5.573,2.5 1.073,0.24 10 false High charge 2.875,3.063 4.156,3.667 1.281,0.604 10 false Charge Amount 1.354,1.344 2.646,1.99 1.292,0.646 10 false Point where bubbles disappear 5.5,0.333 6.677,1.125 1.177,0.792 10 false Specified amount Allowance +/- 30 g (1.1 oz.)

·

High Charge Range:

If the refrigerant is overcharged, the pressure rises on the high-pressure side. High-pressure cut off frequently occurs. This causes insufficient cooling performance and also insufficient compressor lubrication.

·

Low Charge Range:

A shortage of refrigerant causes insufficient cooling performance and low circulation of refrigerant oil, which shortens the compressor life. Operation with insufficient coolant raises the refrigerant temperature and causes heat deterioration of the rubber seals and hoses. Cracking and subsequent refrigerant leakage may occur.



i.

Install the caps onto the service valves on the refrigerant line.



Hide 3. WARM UP ENGINE

NOTICE:

Warm up the engine at less than 2000 rpm for 30 seconds or more after charging it with refrigerant.


Hide 4.INSPECT FOR REFRIGERANT LEAK

a.

After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.


b.

Perform the operation as follows:

·

Stop the engine.

·

Secure good ventilation (the halogen leak detector may react to volatile gases other than refrigerant, such as evaporated gasoline or exhaust gas).

·

Repeat the test 2 or 3 times.

·

Make sure that some refrigerant remains in the refrigeration system.

When the compressor is off: approximately 392 to 588 kPa (4 to 6 kgf/cm2, 57 to 85 psi)


HINT:

It is impossible for the above pressure to be maintained if there is leakage.



c.
I042222C04
2.479,0.177 2.792,0.177 2.792,0.177 2.792,1.49 true 2.302,0.104 2.448,0.281 0.146,0.177 10 *1
*1 Halogen Leak Detector


Using the halogen leak detector, check the refrigerant line, especially at the connection points, for leakage.


d.
I100587C05
1.844,0.833 1.635,0.604 false 1.396,1.854 1.833,1.688 false 1.438,0.49 1.635,0.667 0.198,0.177 10 *1 1.875,1.583 2.094,1.75 0.219,0.167 10 *2
*1 Drain Hose
*2 Halogen Leak Detector


Bring the halogen leak detector close to the drain hose before performing the test.

HINT:
·

After the blower motor has stopped, leave the cooling unit for at least 15 minutes.

·

Place the halogen leak detector sensor under the drain hose.

·

When bringing the halogen leak detector close to the drain hose, make sure that the halogen leak detector does not react to other volatile gases.



If such a reaction is unavoidable, the vehicle must be lifted up.


e.

If no gas leakage is detected from the drain hose, remove the blower motor from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.


f.

Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.