84820
1.INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (for RHD)
| *1 | Window Lock Switch |
| *2 | Driver Switch |
| *3 | Front Passenger Switch |
| *4 | Rear RH Side Switch |
| *5 | Rear LH Side Switch |
| *a | Component without harness connected
(Power Window Regulator Master Switch Assembly) |
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Window Lock Switch Condition | Power Window Switch condition | Tester connection | Specified condition |
|---|---|---|---|
| OFF | UP | 16 (IG) - 14 (PU+)
15 (PD+) - 3 (E) |
Below 1 Ω |
| OFF | OFF | 14 (PU+) - 3 (E)
15 (PD+) - 3 (E) |
Below 1 Ω |
| OFF | DOWN | 16 (IG) - 15 (PD+)
14 (PU+) - 3 (E) |
Below 1 Ω |
| ON | UP | 16 (IG) - 14 (PU+) | Below 1 Ω |
| ON | OFF | 14 (PU+) - 15 (PD+) | Below 1 Ω |
| ON | DOWN | 16 (IG) - 15 (PD+) | Below 1 Ω |
| Window Lock Switch Condition | Power Window Switch condition | Tester connection | Specified condition |
|---|---|---|---|
| OFF | UP | 16 (IG) - 1 (RRU+)
2 (RRD+) - 3 (E) |
Below 1 Ω |
| OFF | OFF | 1 (RRU+) - 3 (E)
2 (RRD+) - 3 (E) |
Below 1 Ω |
| OFF | DOWN | 16 (IG) - 2 (RRD+)
1 (RRU+) - 3 (E) |
Below 1 Ω |
| ON | UP | 16 (IG) - 1 (RRU+) | Below 1 Ω |
| ON | OFF | 1 (RRU+) - 2 (RRD+) | Below 1 Ω |
| ON | DOWN | 16 (IG) - 2 (RRD+) | Below 1 Ω |
| Window Lock Switch Condition | Power Window Switch condition | Tester connection | Specified condition |
|---|---|---|---|
| OFF | UP | 16 (IG) - 8 (RLU+)
9 (RLD+) - 3 (E) |
Below 1 Ω |
| OFF | OFF | 8 (RLU+) - 3 (E)
9 (RLD+) - 3 (E) |
Below 1 Ω |
| OFF | DOWN | 16 (IG) - 9 (RLD+)
8 (RLU+) - 3 (E) |
Below 1 Ω |
| ON | UP | 16 (IG) - 8 (RLU+) | Below 1 Ω |
| ON | OFF | 8 (RLU+) - 9 (RLD+) | Below 1 Ω |
| ON | DOWN | 16 (IG) - 9 (RLD+) | Below 1 Ω |
84820
2.INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (for LHD)
| *1 | Window Lock Switch |
| *2 | Driver Switch |
| *3 | Front Passenger Switch |
| *4 | Rear RH Side Switch |
| *5 | Rear LH Side Switch |
| *a | Component without harness connected
(Power Window Regulator Master Switch Assembly) |
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Window Lock Switch Condition | Power Window Switch condition | Tester connection | Specified condition |
|---|---|---|---|
| OFF | UP | 10 (IG) - 12 (PU+)
11 (PD+) - 3 (E) |
Below 1 Ω |
| OFF | OFF | 12 (PU+) - 3 (E)
11 (PD+) - 3 (E) |
Below 1 Ω |
| OFF | DOWN | 10 (IG) - 11 (PD+)
12 (PU+) - 3 (E) |
Below 1 Ω |
| ON | UP | 10 (IG) - 12 (PU+) | Below 1 Ω |
| ON | OFF | 12 (PU+) - 11 (PD+) | Below 1 Ω |
| ON | DOWN | 10 (IG) - 11 (PD+) | Below 1 Ω |
| Window Lock Switch Condition | Power Window Switch condition | Tester connection | Specified condition |
|---|---|---|---|
| OFF | UP | 10 (IG) - 1 (RRU+)
2 (RRD+) - 3 (E) |
Below 1 Ω |
| OFF | OFF | 1 (RRU+) - 3 (E)
2 (RRD+) - 3 (E) |
Below 1 Ω |
| OFF | DOWN | 10 (IG) - 2 (RRD+)
1 (RRU+) - 3 (E) |
Below 1 Ω |
| ON | UP | 10 (IG) - 1 (RRU+) | Below 1 Ω |
| ON | OFF | 1 (RRU+) - 2 (RRD+) | Below 1 Ω |
| ON | DOWN | 10 (IG) - 2 (RRD+) | Below 1 Ω |
| Window Lock Switch Condition | Power Window Switch condition | Tester connection | Specified condition |
|---|---|---|---|
| OFF | UP | 10 (IG) - 8 (RLU+)
9 (RLD+) - 3 (E) |
Below 1 Ω |
| OFF | OFF | 8 (RLU+) - 3 (E)
9 (RLD+) - 3 (E) |
Below 1 Ω |
| OFF | DOWN | 10 (IG) - 9 (RLD+)
8 (RLU+) - 3 (E) |
Below 1 Ω |
| ON | UP | 10 (IG) - 8 (RLU+) | Below 1 Ω |
| ON | OFF | 8 (RLU+) - 9 (RLD+) | Below 1 Ω |
| ON | DOWN | 10 (IG) - 9 (RLD+) | Below 1 Ω |