Home › Engine / Hybrid System › 1NR-VE ENGINE CONTROL › INTEGRATION RELAY › from 2015.08
RM19Y0E _51 Engine / Hybrid System _042271 1NR-VE ENGINE CONTROL _0196162 INTEGRATION RELAY G

1NR-VE ENGINE CONTROL  INTEGRATION RELAY  INSPECTION  


PROCEDURE

Hide 82641 1.INSPECT NO. 1 INTEGRATION RELAY

A360054E02
3.625,1.5 4.323,1.698 0.698,0.198 10 false MGC 3.74,2.781 4.438,2.979 0.698,0.198 10 false IG1 3.729,4.115 4.427,4.313 0.698,0.198 10 false IG2 3.354,5.458 4.385,5.688 1.031,0.229 10 false RAD FAN NO. 1 3.365,6.76 4.396,6.99 1.031,0.229 10 false RAD FAN NO. 2 3.458,8.104 4.49,8.333 1.031,0.229 10 false FUEL PUMP 0.521,0.729 0.833,0.927 0.313,0.198 10 false 1D 0.51,1.646 0.823,1.844 0.313,0.198 10 false 1D 0.51,2.052 0.823,2.25 0.313,0.198 10 false 1D 0.531,3.365 0.844,3.563 0.313,0.198 10 false 1D 0.521,3.781 0.833,3.979 0.313,0.198 10 false 1D 0.521,4.677 0.833,4.875 0.313,0.198 10 false 1E 0.521,7.333 0.833,7.531 0.313,0.198 10 false 1D 6.5,0.729 6.813,0.927 0.313,0.198 10 false 1D 6.51,2.052 6.823,2.25 0.313,0.198 10 false 1E 6.51,4.688 6.823,4.885 0.313,0.198 10 false 1E 6.5,5.104 6.813,5.302 0.313,0.198 10 false 1D 6.51,6.021 6.823,6.219 0.313,0.198 10 false 1E 6.5,7.333 6.813,7.531 0.313,0.198 10 false 1D 6.521,6.427 6.833,6.625 0.313,0.198 10 false 1D 6.51,7.76 6.823,7.958 0.313,0.198 10 false 1D 0.521,1.875 0.802,2.115 0.281,0.24 10 false 10 0.573,0.542 0.854,0.781 0.281,0.24 10 false 8 0.563,1.458 0.844,1.698 0.281,0.24 10 false 9 0.583,3.188 0.865,3.427 0.281,0.24 10 false 5 0.552,3.604 0.833,3.844 0.281,0.24 10 false 1 0.563,4.51 0.844,4.75 0.281,0.24 10 false 4 0.521,7.146 0.802,7.385 0.281,0.24 10 false 11 6.552,0.531 6.833,0.771 0.281,0.24 10 false 7 6.51,1.146 6.823,1.344 0.313,0.198 10 false 1D 6.552,0.969 6.833,1.208 0.281,0.24 10 false 2 6.552,1.885 6.833,2.125 0.281,0.24 10 false 5 6.521,2.458 6.833,2.656 0.313,0.198 10 false 1F 6.521,2.281 6.802,2.521 0.281,0.24 10 false 18 6.552,4.49 6.833,4.729 0.281,0.24 10 false 1 6.552,4.927 6.833,5.167 0.281,0.24 10 false 6 6.563,5.802 6.844,6.042 0.281,0.24 10 false 3 6.521,6.25 6.802,6.49 0.281,0.24 10 false 12 6.542,7.146 6.823,7.385 0.281,0.24 10 false 3 6.542,7.594 6.823,7.833 0.281,0.24 10 false 4

A360056E01
3.531,1.948 4.76,2.146 1.229,0.198 10 false ST NO. 2 3.521,3.573 4.75,3.771 1.229,0.198 10 false E-THRO 3.573,4.917 4.802,5.115 1.229,0.198 10 false EFI-MAIN 0.5,0.792 0.813,0.99 0.313,0.198 10 false 1J 0.5,1.208 0.813,1.406 0.313,0.198 10 false 1F 0.5,1.625 0.813,1.823 0.313,0.198 10 false 1F 0.5,2.042 0.813,2.24 0.313,0.198 10 false 1F 0.5,2.823 0.813,3.021 0.313,0.198 10 false 1F 0.5,3.24 0.813,3.438 0.313,0.198 10 false 1F 0.49,4.135 0.802,4.333 0.313,0.198 10 false 1F 6.479,1.208 6.792,1.406 0.313,0.198 10 false 1E 6.49,1.625 6.802,1.823 0.313,0.198 10 false 1F 6.479,2.042 6.792,2.24 0.313,0.198 10 false 1F 6.49,2.823 6.802,3.021 0.313,0.198 10 false 1F 6.49,3.24 6.802,3.438 0.313,0.198 10 false 1F 6.49,4.563 6.802,4.76 0.313,0.198 10 false 1F 6.49,4.135 6.802,4.333 0.313,0.198 10 false 1J 0.531,0.594 0.76,0.823 0.229,0.229 10 false 4 0.531,1.021 0.76,1.25 0.229,0.229 10 false 1 0.5,1.438 0.729,1.667 0.229,0.229 10 false 13 0.5,1.844 0.729,2.073 0.229,0.229 10 false 14 0.542,2.635 0.771,2.865 0.229,0.229 10 false 2 0.542,3.063 0.771,3.292 0.229,0.229 10 false 7 6.521,3.948 6.75,4.177 0.229,0.229 10 false 3 0.49,3.948 0.719,4.177 0.229,0.229 10 false 17 6.49,1.427 6.719,1.656 0.229,0.229 10 false 15 6.479,1.844 6.708,2.073 0.229,0.229 10 false 16 6.479,3.052 6.708,3.281 0.229,0.229 10 false 10 6.521,4.375 6.75,4.604 0.229,0.229 10 false 5 6.531,1 6.76,1.229 0.229,0.229 10 false 6 6.521,2.625 6.75,2.854 0.229,0.229 10 false 9 4.167,1.083 4.396,1.313 0.229,0.229 10 false 3 4.177,1.521 4.406,1.75 0.229,0.229 10 false 1 3.323,1.094 3.552,1.323 0.229,0.229 10 false 5 3.313,1.521 3.542,1.75 0.229,0.229 10 false 2

a.

E-THRO relay

i.
A360057C01
0.49,1.875 0.99,2.125 0.5,0.25 1.625,1.875 2.125,2.125 0.5,0.25 2.51,1.885 3.01,2.135 0.5,0.25 0.688,0.333 1.188,0.583 0.5,0.25 0.094,0.094 0.406,0.292 0.313,0.198 10 false *a 2.667,1.938 2.979,2.135 0.313,0.198 10 false 1D 1.792,1.927 2.104,2.125 0.313,0.198 10 false 1E 0.677,1.917 0.99,2.115 0.313,0.198 10 false 1F 0.875,0.385 1.188,0.583 0.313,0.198 10 false 1J
*a Component without harness connected
(No. 1 Integration Relay)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1F-2 - 1F-9 Battery voltage is not applied to terminals 1J-3 or 1F-10 and 1F-7 10 kΩ or higher
1F-2 - 1F-9 Battery voltage is applied to terminals 1J-3 or 1F-10 and 1F-7 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



b.

EFI-MAIN relay

i.
A360057C01
0.49,1.875 0.99,2.125 0.5,0.25 1.625,1.875 2.125,2.125 0.5,0.25 2.51,1.885 3.01,2.135 0.5,0.25 0.688,0.333 1.188,0.583 0.5,0.25 0.094,0.094 0.406,0.292 0.313,0.198 10 false *a 2.667,1.938 2.979,2.135 0.313,0.198 10 false 1D 1.792,1.927 2.104,2.125 0.313,0.198 10 false 1E 0.677,1.917 0.99,2.115 0.313,0.198 10 false 1F 0.875,0.385 1.188,0.583 0.313,0.198 10 false 1J
*a Component without harness connected
(No. 1 Integration Relay)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1F-10 - 1F-17 Battery voltage is not applied to terminals 1F-5 and 1F-17 10 kΩ or higher
1J-3 - 1F-17
1F-10 - 1F-17 Battery voltage is applied to terminals 1F-5 and 1F-17 Below 1 Ω
1J-3 - 1F-17


If the result is not as specified, replace the No. 1 integration relay.



c.

MGC relay

i.
A360028C01
0.615,0.313 1.115,0.563 0.5,0.25 1.583,0.302 2.083,0.552 0.5,0.25 2.469,0.302 2.969,0.552 0.5,0.25 0.073,0.063 0.385,0.26 0.313,0.198 10 false *a 2.646,0.354 2.958,0.552 0.313,0.198 10 false 1D 1.75,0.354 2.063,0.552 0.313,0.198 10 false 1E 0.792,0.375 1.104,0.573 0.313,0.198 10 false 1F
*a Component without harness connected
(No. 1 Integration Relay)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1D-7 - 1D-8 Battery voltage is not applied to terminals 1D-9 or 1D-10 and 1D-2 10 kΩ or higher
1D-7 - 1D-8 Battery voltage is applied to terminals 1D-9 or 1D-10 and 1D-2 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



d.

IG1 relay

i.
A360028C01
0.615,0.313 1.115,0.563 0.5,0.25 1.583,0.302 2.083,0.552 0.5,0.25 2.469,0.302 2.969,0.552 0.5,0.25 0.073,0.063 0.385,0.26 0.313,0.198 10 false *a 2.646,0.354 2.958,0.552 0.313,0.198 10 false 1D 1.75,0.354 2.063,0.552 0.313,0.198 10 false 1E 0.792,0.375 1.104,0.573 0.313,0.198 10 false 1F
*a Component without harness connected
(No. 1 Integration Relay)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1D-9 - 1E-5 Battery voltage is not applied to terminals 1D-1 and 1F-18 10 kΩ or higher
1D-10 - 1E-5
1D-9 - 1E-5 Battery voltage is applied to terminals 1D-1 and 1F-18 Below 1 Ω
1D-10 - 1E-5


If the result is not as specified, replace the No. 1 integration relay.



e.

IG2 relay

i.
A360028C01
0.615,0.313 1.115,0.563 0.5,0.25 1.583,0.302 2.083,0.552 0.5,0.25 2.469,0.302 2.969,0.552 0.5,0.25 0.073,0.063 0.385,0.26 0.313,0.198 10 false *a 2.646,0.354 2.958,0.552 0.313,0.198 10 false 1D 1.75,0.354 2.063,0.552 0.313,0.198 10 false 1E 0.792,0.375 1.104,0.573 0.313,0.198 10 false 1F
*a Component without harness connected
(No. 1 Integration Relay)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1D-5 - 1E-5 Battery voltage is not applied to terminals 1D-1 and 1F-18 10 kΩ or higher
1D-5 - 1E-5 Battery voltage is applied to terminals 1D-1 and 1F-18 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



f.

RAD/FAN NO. 1 relay

i.
A360028C01
0.615,0.313 1.115,0.563 0.5,0.25 1.583,0.302 2.083,0.552 0.5,0.25 2.469,0.302 2.969,0.552 0.5,0.25 0.073,0.063 0.385,0.26 0.313,0.198 10 false *a 2.646,0.354 2.958,0.552 0.313,0.198 10 false 1D 1.75,0.354 2.063,0.552 0.313,0.198 10 false 1E 0.792,0.375 1.104,0.573 0.313,0.198 10 false 1F
*a Component without harness connected
(No. 1 Integration Relay)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1E-1 - 1E-4 Battery voltage is not applied to terminals 1D-5 and 1D-6 10 kΩ or higher
1E-1 - 1E-4 Battery voltage is applied to terminals 1D-5 and 1D-6 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



g.

RAD/FAN NO. 2 relay

i.
A360028C01
0.615,0.313 1.115,0.563 0.5,0.25 1.583,0.302 2.083,0.552 0.5,0.25 2.469,0.302 2.969,0.552 0.5,0.25 0.073,0.063 0.385,0.26 0.313,0.198 10 false *a 2.646,0.354 2.958,0.552 0.313,0.198 10 false 1D 1.75,0.354 2.063,0.552 0.313,0.198 10 false 1E 0.792,0.375 1.104,0.573 0.313,0.198 10 false 1F
*a Component without harness connected
(No. 1 Integration Relay)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1E-3 - 1E-4 Battery voltage is not applied to terminals 1D-5 and 1D-12 10 kΩ or higher
1E-3 - 1E-4 Battery voltage is applied to terminals 1D-5 and 1D-12 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



h.

Fuel pump relay

i.
A360028C01
0.615,0.313 1.115,0.563 0.5,0.25 1.583,0.302 2.083,0.552 0.5,0.25 2.469,0.302 2.969,0.552 0.5,0.25 0.073,0.063 0.385,0.26 0.313,0.198 10 false *a 2.646,0.354 2.958,0.552 0.313,0.198 10 false 1D 1.75,0.354 2.063,0.552 0.313,0.198 10 false 1E 0.792,0.375 1.104,0.573 0.313,0.198 10 false 1F
*a Component without harness connected
(No. 1 Integration Relay)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1D-3 - 1D-11 Battery voltage is not applied to terminals 1D-4 and 1D-5 10 kΩ or higher
1D-3 - 1D-11 Battery voltage is applied to terminals 1D-4 and 1D-5 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



i.

ST NO. 2 relay circuit

i.

Remove the ST NO. 2 relay.


ii.
A360055C01
0.646,3 1.146,3.25 0.5,0.25 1.615,3.01 2.115,3.26 0.5,0.25 2.51,3.021 3.01,3.271 0.5,0.25 1.656,0.552 2.156,0.802 0.5,0.25 2.708,3.063 3.021,3.26 0.313,0.198 10 false 1D 1.792,3.063 2.104,3.26 0.313,0.198 10 false 1E 0.823,3.052 1.135,3.25 0.313,0.198 10 false 1F 1.844,0.615 2.156,0.813 0.313,0.198 10 false 1J 0.083,0.083 0.396,0.24 0.313,0.156 10 false *a
*a Component without harness connected
(No. 1 Integration Relay)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1E-6 - 3 Always Below 1 Ω
1F-1 - 5 Always Below 1 Ω
1F-13 - 2 Always Below 1 Ω
1F-14 - 2 Always Below 1 Ω
1F-15 -1 Always Below 1 Ω
1F-16 -1 Always Below 1 Ω
1J-4 - 5 Always Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.