1.INSPECT INTAKE AIR FLOW METER ASSEMBLY
| *a | Platinum Hot Wire (Heater) |
Perform a visual check for any foreign matter on the platinum hot wire (heater) of the intake air flow meter assembly shown in the illustration.
There is no foreign matter.
If the result is not as specified, replace the intake air flow meter assembly.
| *a | Component without harness connected
(Intake Air Flow Meter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (THA) - 2 (E2) | -20°C (-4°F) | 13.6 to 18.4 kΩ |
| 20°C (68°F) | 2.21 to 2.69 kΩ | |
| 60°C (140°F) | 0.49 to 0.67 kΩ |
If the resistance is not as specified, replace the intake air flow meter assembly.