82641
1.INSPECT NO. 1 INTEGRATION RELAY
E-THRO relay
| *a | Component without harness connected
(No. 1 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1F-2 - 1F-9 | Battery voltage is not applied to terminals 1J-3 or 1F-10 and 1F-7 | 10 kΩ or higher |
| 1F-2 - 1F-9 | Battery voltage is applied to terminals 1J-3 or 1F-10 and 1F-7 | Below 1 Ω |
If the result is not as specified, replace the No. 1 integration relay.
EFI-MAIN relay
| *a | Component without harness connected
(No. 1 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1F-10 - 1F-17 | Battery voltage is not applied to terminals 1F-5 and 1F-17 | 10 kΩ or higher |
| 1J-3 - 1F-17 | ||
| 1F-10 - 1F-17 | Battery voltage is applied to terminals 1F-5 and 1F-17 | Below 1 Ω |
| 1J-3 - 1F-17 |
If the result is not as specified, replace the No. 1 integration relay.
MGC relay
| *a | Component without harness connected
(No. 1 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1D-7 - 1D-8 | Battery voltage is not applied to terminals 1D-9 or 1D-10 and 1D-2 | 10 kΩ or higher |
| 1D-7 - 1D-8 | Battery voltage is applied to terminals 1D-9 or 1D-10 and 1D-2 | Below 1 Ω |
If the result is not as specified, replace the No. 1 integration relay.
IG1 relay
| *a | Component without harness connected
(No. 1 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1D-9 - 1E-5 | Battery voltage is not applied to terminals 1D-1 and 1F-18 | 10 kΩ or higher |
| 1D-10 - 1E-5 | ||
| 1D-9 - 1E-5 | Battery voltage is applied to terminals 1D-1 and 1F-18 | Below 1 Ω |
| 1D-10 - 1E-5 |
If the result is not as specified, replace the No. 1 integration relay.
IG2 relay
| *a | Component without harness connected
(No. 1 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1D-5 - 1E-5 | Battery voltage is not applied to terminals 1D-1 and 1F-18 | 10 kΩ or higher |
| 1D-5 - 1E-5 | Battery voltage is applied to terminals 1D-1 and 1F-18 | Below 1 Ω |
If the result is not as specified, replace the No. 1 integration relay.
RAD/FAN NO. 1 relay
| *a | Component without harness connected
(No. 1 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1E-1 - 1E-4 | Battery voltage is not applied to terminals 1D-5 and 1D-6 | 10 kΩ or higher |
| 1E-1 - 1E-4 | Battery voltage is applied to terminals 1D-5 and 1D-6 | Below 1 Ω |
If the result is not as specified, replace the No. 1 integration relay.
RAD/FAN NO. 2 relay
| *a | Component without harness connected
(No. 1 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1E-3 - 1E-4 | Battery voltage is not applied to terminals 1D-5 and 1D-12 | 10 kΩ or higher |
| 1E-3 - 1E-4 | Battery voltage is applied to terminals 1D-5 and 1D-12 | Below 1 Ω |
If the result is not as specified, replace the No. 1 integration relay.
Fuel pump relay
| *a | Component without harness connected
(No. 1 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1D-3 - 1D-11 | Battery voltage is not applied to terminals 1D-4 and 1D-5 | 10 kΩ or higher |
| 1D-3 - 1D-11 | Battery voltage is applied to terminals 1D-4 and 1D-5 | Below 1 Ω |
If the result is not as specified, replace the No. 1 integration relay.
ST NO. 2 relay circuit
Remove the ST NO. 2 relay.
| *a | Component without harness connected
(No. 1 Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1E-6 - 3 | Always | Below 1 Ω |
| 1F-1 - 5 | Always | Below 1 Ω |
| 1F-13 - 2 | Always | Below 1 Ω |
| 1F-14 - 2 | Always | Below 1 Ω |
| 1F-15 -1 | Always | Below 1 Ω |
| 1F-16 -1 | Always | Below 1 Ω |
| 1J-4 - 5 | Always | Below 1 Ω |
If the result is not as specified, replace the No. 1 integration relay.