1.INSPECT FOR FIN FOR BLOCKAGE
If the fins are clogged, wash them with water or a steam cleaner and then dry them with compressed air.
If the distance between the steam cleaner and core is too small, the fins may be damaged. So, keep to the following injection distance.
| Injection Pressure
kPa (kgf/cm2, psi) |
Injection Distance
mm (in.) |
| 2,942 to 4,903
(30 to 50, 427 to 711) |
300 (11.811) |
| 4,903 to 7,845
(50 to 80, 711 to 1,138) |
500 (19.685) |
If the fins are bent, straighten them using a screwdriver or pliers.
Do not expose electronic components to water.