1.INSPECT THERMOSTAT
Check the valve opening temperature of the thermostat (element, spring and frame).
80 to 84°C (176 to 183°F)
If the valve opening temperature is not as specified, replace the thermostat (element, spring and frame).
| *a | 8.5 mm or more |
Check the valve lift.
8.5 mm (0.335 in.) or more at 95°C (203°F)
If the valve lift is not as specified, replace the thermostat (element, spring and frame).
Check that the valve is fully closed when the element is at low temperatures (below 77°C (171°F)).
If the valve is not fully closed, replace the thermostat (element, spring and frame).