Home › Engine / Hybrid System › 2NR-VE COOLING › RADIATOR › from 2015.08
RM19Y0E _51 Engine / Hybrid System _042282 2NR-VE COOLING _0196242 RADIATOR N

2NR-VE COOLING  RADIATOR  ON-VEHICLE CLEANING  


PROCEDURE

Hide 1.INSPECT FOR FIN FOR BLOCKAGE

a.
A143087

If the fins are clogged, wash them with water or a steam cleaner and then dry them with compressed air.

NOTICE:
·

If the distance between the steam cleaner and core is too small, the fins may be damaged. So, keep to the following injection distance.

Injection Pressure
kPa (kgf/cm2, psi)
Injection Distance
mm (in.)
2,942 to 4,903
(30 to 50, 427 to 711)
300 (11.811)
4,903 to 7,845
(50 to 80, 711 to 1,138)
500 (19.685)

·

If the fins are bent, straighten them using a screwdriver or pliers.

·

Do not expose electronic components to water.