If all of the power windows do not operate, the power window regulator master switch assembly may have no power or may be malfunctioning.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
| *A | for RHD |
| *B | for LHD |
| *a | Front view of wire harness connector
(to Power Window Regulator Master Switch Assembly) |
Disconnect the F9*1 or G9*2 power window regulator master switch assembly connector.
*1: for RHD
*2: for LHD
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| F9-16 (IG) - Body ground | Ignition switch ON | 11 to 14 V |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G9-10 (IG) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F9*1 or G9*1 power window regulator master switch assembly connector.
*1: for RHD
*2: for LHD
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F9-3 (E) - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G9-3 (E) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG