Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › TOYOTA PARKING ASSIST-SENSOR SYSTEM › from 2015.08
RM19Y0E _56 Audio / Visual / Telematics _003001 PARK ASSIST / MONITORING _0015174 TOYOTA PARKING ASSIST-SENSOR SYSTEM J

PARK ASSIST / MONITORING  TOYOTA PARKING ASSIST-SENSOR SYSTEM  Indicator Circuit  


DESCRIPTION

The warning indicator lights are installed in the combination meter assembly.

WIRING DIAGRAM

E326353E01
5.51,2.031 6.698,2.75 1.188,0.719 10 false Clearance Warning ECU Assembly 5.521,1.854 6.146,2.25 0.625,0.396 10 false J11 3.042,1.542 5.031,1.948 1.99,0.406 10 false Combination Meter Assembly 3.052,1.375 3.677,1.771 0.625,0.396 10 false E34 2.042,1.135 2.906,1.573 0.865,0.438 10 false ECU IG2 3.51,0.979 3.885,1.323 0.375,0.344 10 false IG 4.052,0.969 4.667,1.344 0.615,0.375 10 false LD+ 5.667,0.969 6.281,1.344 0.615,0.375 10 false LD 5.365,0.854 5.979,1.229 0.615,0.375 10 false 11 4.438,0.854 5.052,1.229 0.615,0.375 10 false 20 3.302,0.854 3.917,1.229 0.615,0.375 10 false 5 0.313,0.958 1.656,1.792 1.344,0.833 10 false from No. 1 Integration Relay

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following procedure.


PROCEDURE

1.CHECK HARNESS AND CONNECTOR (POWER SOURCE - COMBINATION METER ASSEMBLY)
a.

Disconnect the E34 combination meter assembly connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
E34-5 (IG) - Body ground Ignition switch ON 11 to 14 V


Result:
Proceed to
OK
NG




OK

2.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - CLEARANCE WARNING ECU)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

2.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - CLEARANCE WARNING ECU)
a.

Disconnect the E34 combination meter assembly connector.


b.

Disconnect the J11 clearance warning ECU assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):
Tester Connection Condition Specified Condition
E34-20 (LD+) - J11-11 (LD) Always Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Condition Specified Condition
E34-20 (LD+) or J11-11 (LD) - Body ground Always 10 kΩ or higher


Result:
Proceed to
OK
NG




OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR