CHECK ECM
Measure the voltage and resistance according to the value(s) in the table below.
The standard normal voltage between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| C50-86 (ALT) - C50-4 (E01) | R-B - W-B | Generator assembly | Idling with warm engine | 11 to 14 V |
| C50-34 (BATP) - C50-100 (E2) | P-L - BR-W | Battery current sensor | Ignition switch ON, engine stopped | 0.5 to 4.5 V |
| C50-56 (VC) - C50-100 (E2) | L-Y - BR-W | Power source of battery current sensor assembly | Ignition switch ON, engine stopped | 4.5 to 5.5 V |
| C50-78 (CM) - C50-100 (E2) | LG-R - BR-W | Battery temperature sensor (built into battery current sensor assembly) | Idling with warm engine | 0.5 to 4.5 V |
| C50-85 (L) - C50-4 (E01) | L-R - W-B | Generator assembly | Idling with warm engine | 11 to 14 V |
| C50-100 (E2) - Body ground | BR-W - Body ground | Ground (Battery current sensor) | Always | Below 1Ω |
| C50-4 (E01) - Body ground | W-B - Body ground | Ground | Always | Below 1Ω |
| C50-107 (ALTO) - C50-4 (E01) | B-R - W-B | Generator assembly | Idling with warm engine | Pulse generation (See waveform 1) |
| C50-108 (ALTI) - C50-4 (E01) | G-Y - W-B | Generator assembly | Idling with warm engine | Pulse generation (See waveform 2) |
Using an oscilloscope, check waveform 1.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | C50-107 (ALTO) - C50-4 (E01) |
| Tool Setting | 2 V/DIV., 50 ms./DIV. |
| Condition | Idling with warm engine |
A constant value is not output, as the duty ratio varies depending on the electrical load and battery condition.
Using an oscilloscope, check waveform 2.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | C50-108 (ALTI) - C50-4 (E01) |
| Tool Setting | 2 V/DIV., 2 ms./DIV. |
| Condition | Idling with warm engine |
A constant value is not output, as the duty ratio varies depending on the electrical load and battery condition.