Home › Power Source / Network › 1NR-VE BATTERY / CHARGING › CHARGING SYSTEM › from 2015.08
RM19Y0E _57 Power Source / Network _041458 1NR-VE BATTERY / CHARGING _0192571 CHARGING SYSTEM U

1NR-VE BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECM  


CHECK ECM


A348484N08
2.052,0.469 2.385,0.719 0.333,0.25 4.385,0.469 4.719,0.719 0.333,0.25 2.094,0.51 2.552,0.708 0.458,0.198 10 false A24 4.427,0.51 4.885,0.708 0.458,0.198 10 false C50

a.

Measure the voltage and resistance according to the value(s) in the table below.

HINT:

The standard normal voltage between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
C50-86 (ALT) - C50-4 (E01) R-B - W-B Generator assembly Idling with warm engine 11 to 14 V
C50-34 (BATP) - C50-100 (E2) P-L - BR-W Battery current sensor Ignition switch ON, engine stopped 0.5 to 4.5 V
C50-56 (VC) - C50-100 (E2) L-Y - BR-W Power source of battery current sensor assembly Ignition switch ON, engine stopped 4.5 to 5.5 V
C50-78 (CM) - C50-100 (E2) LG-R - BR-W Battery temperature sensor (built into battery current sensor assembly) Idling with warm engine 0.5 to 4.5 V
C50-85 (L) - C50-4 (E01) L-R - W-B Generator assembly Idling with warm engine 11 to 14 V
C50-100 (E2) - Body ground BR-W - Body ground Ground (Battery current sensor) Always Below 1Ω
C50-4 (E01) - Body ground W-B - Body ground Ground Always Below 1Ω
C50-107 (ALTO) - C50-4 (E01) B-R - W-B Generator assembly Idling with warm engine Pulse generation (See waveform 1)
C50-108 (ALTI) - C50-4 (E01) G-Y - W-B Generator assembly Idling with warm engine Pulse generation (See waveform 2)


b.
A287459E01
2.948,1.667 3.406,1.865 0.458,0.198 10 GND 2.667,0.302 3.313,0.51 0.646,0.208 10 2 V/DIV. 0.833,1.958 1.708,2.177 0.875,0.219 10 50 ms./DIV.

Using an oscilloscope, check waveform 1.

Waveform 1:
Item Content
Terminal No. (Symbol) C50-107 (ALTO) - C50-4 (E01)
Tool Setting 2 V/DIV., 50 ms./DIV.
Condition Idling with warm engine

HINT:

A constant value is not output, as the duty ratio varies depending on the electrical load and battery condition.



c.
A287460E02
2.958,1.677 3.417,1.875 0.458,0.198 10 false GND 2.708,0.344 3.406,0.583 0.698,0.24 10 false 2 V/DIV. 0.948,1.979 1.802,2.167 0.854,0.188 10 false 2 ms./DIV.

Using an oscilloscope, check waveform 2.

Waveform 2:
Item Content
Terminal No. (Symbol) C50-108 (ALTI) - C50-4 (E01)
Tool Setting 2 V/DIV., 2 ms./DIV.
Condition Idling with warm engine

HINT:

A constant value is not output, as the duty ratio varies depending on the electrical load and battery condition.