DATA LIST
Using the GTS or Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Turn the ignition switch off.
Connect the GTS or Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the GTS or Techstream on.
Enter the following menus: Chassis / EPS / Data List.
According to the display on GTS or Techstream, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Vehicle speed | Vehicle speed from meter | Min.: 0 km/h (0 mph)
Max.: 255 km/h (158.5 mph) |
Vehicle stopped: 0 km/h (0 mph)
Vehicle driven at constant speed: No significant fluctuation |
- |
| Engine revolution speed | Engine speed | Min.: 0 rpm | Engine is running at a constant speed | No significant fluctuation |
| Motor actual current | Current to motor | Min.: -55.91A
Max.: 55.91A |
Value changes in proportion to steering effort | Power steering is in operation |
| Motor instruction current | Requested current to motor | Min.: -55.91A
Max.: 55.91A |
Value changes in proportion to steering effort | Power steering is in operation |
| Thermistor temperature | ECU substrate temperature | Min.: -125°C (-257°F)
Max.: 125°C (257°F) |
-125 to 125°C (-257 to 257°F) | Ignition switch ON |
| PIG power supply | Power source voltage to activate motor | Min.: 0 V
Max.: 21.1531 V |
11 to 14 V | Power steering is in operation |
| IG power supply | ECU power source voltage | Min.: 0 V
Max.: 21.1531 V |
11 to 14 V | Ignition switch ON |
| Steering torque | Steering wheel torque | Min.: -19.60 Nm
Max.: 19.60 Nm |
Value changes in proportion to steering effort | The engine is running and the steering wheel is being turned. |
| Output of torque sensor 1 | Torque sensor 1 output value | Min.: 0 V
Max.: 5 V |
Steering wheel not turned (without load): 2.2 to 2.8 V
Steering wheel not turned (without load): 2.2 to 4.0 V Steering wheel turned to left with vehicle stopped: 1.0 to 2.8 V |
- |
| Output of torque sensor 2 | Torque sensor 2 output value | Min.: 0 V
Max.: 5 V |
Steering wheel not turned (without load): 2.2 to 2.8 V
Steering wheel turned to right with vehicle stopped: 2.2 to 4.0 V Steering wheel turned to left with vehicle stopped: 1.0 to 2.8 V |
- |
| Motor voltage (+) | Motor terminal M1 voltage | Min.: 0 V
Max.: 20.00 V |
Steering wheel turned to right: Below 1 V
Steering wheel turned to left: 11 to 14 V |
- |
| Motor voltage (-) | Motor terminal M2 voltage | Min.: 0 V
Max.: 20.00 V |
Steering wheel turned to right: 11 to 14 V
Steering wheel turned to left: Below 1 V |
- |
| IG switch status | Ignition switch signal | ON or OFF | ON: Ignition switch ON
OFF: Ignition switch ACC or off |
- |
| Torque sensor power supply | Torque sensor power source voltage | Min.: 0 V
Max.: 21.1531 V |
5 to 13 V | Power steering is in operation |
| No. of diagnosis codes | Number of detected DTCs when freeze frame data stored | Min.: 0
Max.: 255 |
- | - |
| Diagnosis mode | Diagnosis mode | Normal/Check | - | - |