Home › Drivetrain › A4R AUTOMATIC TRANSMISSION / TRANSAXLE › VALVE BODY ASSEMBLY › from 2015.08
RM19Y0E _52 Drivetrain _041457 A4R AUTOMATIC TRANSMISSION / TRANSAXLE _0197963 VALVE BODY ASSEMBLY G

A4R AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 35220 1.INSPECT SHIFT SOLENOID VALVE SL1

a.
C197715C48
1.76,1 2.24,0.531 true 1.76,2.979 2.24,2.521 true 1.49,0.979 1.021,0.531 true 1.479,2.979 1.021,2.521 true 2.292,0.385 2.438,0.583 0.146,0.198 10 false 1 0.094,0.042 0.438,0.385 0.344,0.344 10 false *a 0.896,0.385 1.042,0.583 0.146,0.198 10 false 2 2.292,2.385 2.438,2.583 0.146,0.198 10 false 1 0.896,2.385 1.042,2.583 0.146,0.198 10 false 2 1.865,3.948 2.115,4.146 0.25,0.198 10 false (+) 1.146,3.948 1.396,4.146 0.25,0.198 10 false (-)
*a Component without harness connected
(Shift Solenoid Valve SL1)


Measure the resistance according to the value(s) in the table below.

Standard Resistance
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω


b.

Connect the positive (+) lead with a 21 W bulb to terminal 1 and the negative (-) lead to terminal 2 of the connector, then check the movement of the shift solenoid valve SL1.

OK:

The solenoid makes an operating sound.


If the result is not as specified, replace the transmission valve body assembly.


Hide 35210 2.INSPECT SHIFT SOLENOID VALVE SL2

HINT:

Use the same procedure as for the shift solenoid valve SL1.


Hide 35210 3.INSPECT SHIFT SOLENOID VALVE SL3

HINT:

Use the same procedure as for the shift solenoid valve SL1.


Hide 35280 4.INSPECT LOCK UP CONTROL SOLENOID ASSEMBLY

HINT:

Use the same procedure as for the shift solenoid valve SL1.


Hide 35290 5.INSPECT LINE PRESSURE CONTROL SOLENOID ASSEMBLY

HINT:

Use the same procedure as for the shift solenoid valve SL1.


Hide 35240 6.INSPECT SHIFT SOLENOID VALVE DSL

a.
C209925C01
0.094,0.063 0.448,0.313 0.354,0.25 10 *a 2.365,0.177 2.698,0.417 0.333,0.24 10 (+) 1.698,0.177 1.938,0.406 0.24,0.229 10 (-)
*a Component without harness connected
(Shift Solenoid Valve DSL)


Measure the resistance according to the value(s) in the table below.

Standard Resistance
Tester Connection Condition Specified Condition
Connector terminal - Solenoid Body 20°C (68°F) 12.2 to 13.4 Ω


b.

Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

OK:

The solenoid makes an operating sound.


If the result is not as specified, replace the shift solenoid valve DSL.