2NR-VE BATTERY / CHARGING  CHARGING SYSTEM  DATA LIST / ACTIVE TEST  


DATA LIST


HINT:

Using the GTS or Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under Normal Condition are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the GTS or Techstream to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the GTS or Techstream on.


f.

Enter the following menus: Powertrain / EFI / Data List.


g.

According to the display on the GTS or Techstream, read the Data List.

Powertrain > EFI > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery voltage Battery voltage Min.: 0 V, Max.: 65.535 V 11 to 14 V: Ignition switch ON If the result is not as specified, abnormal battery voltage is suspected.
Battery current Battery current Min.: -100 A, Max.: 149.996 A Value increases → decreases → becomes stable: Immediately after engine start, during idling (air conditioner off, shift lever in N, charging light is off)
·

Calculated based on the signal from the battery current sensor assembly.

·

Positive value: Charging

·

Negative value: Discharging


Battery temperature Battery temperature Min.: -45°C, Max.: 40914.375°C Same level as ambient temperature around battery: Ignition switch ON Calculated based on the signal from the battery current sensor assembly (temperature sensor).
Alternator field duty Generator output duty Min.: 0%, Max.: 399.993% Increases to a certain value, and then becomes stable: Immediately after engine start, during idling (no electric load, air conditioner OFF) Determines ON/OFF status of alternator FD terminal and displays it as a duty ratio.
Increases: After engine warm-up, during idling, electric load is turned from off to on.
Alternator regulator duty Generator regulator duty Min.: 0%, Max.: 399.993% Changes according to alternator output: During charging control If the result is not as specified, a malfunction of the charging control system is suspected.
Number of diagnosis codes Number of DTCs Min.: 0, Max.: 255 0 -

HINT:

Normal Condition: If no idling conditions are specified, the shift lever should be in N (Neutral) or P, and the A/C switch and all accessory switches should be off.




ACTIVE TEST


HINT:

Using the GTS or Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Connect the GTS or Techstream to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS or Techstream on.


d.

Enter the following menus: Powertrain / EFI / Active Test.


e.

According to the display on the GTS or Techstream, perform the Active Test.

Powertrain > Engine and ECT > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Alternator regulator Request output voltage of generator regulator during forced activation Between 12.5 and 14.8 V Test is possible after engine start