RM19Y0E
_V1
General
_002965
SPECIFICATIONS
_0193136
1NR-VE ENGINE CONTROL
F
SPECIFICATIONS 1NR-VE ENGINE CONTROL SERVICE DATA
Spark Plug
| Standard Insulation Resistance
|
Spark plug (terminal part) - Ground
|
10 MΩ or higher
|
| Spark Plug Type
|
DENSO made
|
SC16HR11
|
| Maximum Electrode Gap
|
for Used Spark Plug
|
1.3 mm (0.0512 in.)
|
| Standard Electrode Gap
|
for New Spark Plug
|
1.0 to 1.1 mm (0.0394 to 0.0433 in.)
|
Camshaft Timing Oil Control Valve Assembly
| Standard Resistance
|
20°C (68°F)
|
6.9 to 7.9 Ω
|
Throttle Body with Motor Assembly
| Standard Resistance
|
1 (M-) - 2 (M+)
|
25°C (77°F)
|
1.28 to 1.48 Ω
|
Intake Air Flow Meter Assembly
| Standard Resistance
|
1 (THA) - 2 (E2)
|
-20°C (4°F)
|
13.6 to 18.4 kΩ
|
| 20°C (68°F)
|
2.21 to 2.69 kΩ
|
| 80°C (176°F)
|
0.49 to 0.67 kΩ
|
Engine Coolant Temperature Sensor
| Standard Resistance
|
1 - 2
|
20°C (68°F)
|
2.32 to 2.59 kΩ
|
| 80°C (176°F)
|
0.310 to 0.326 kΩ
|
Knock Control Sensor
| Standard Resistance
|
20°C (68°F)
|
120 to 280 kΩ
|
Oxygen Sensor
| Standard Resistance
|
1 (HT1B) - 2 (+B)
|
20°C (68°F)
|
11.7 to 15.5 Ω
|
| 1 (HT1B) - 4 (E2)
|
Always
|
10 kΩ or higher
|
No. 1 Integration Relay (E-THRO relay)
| Standard Resistance
|
1F-2 - 1F-9
|
Battery voltage is not applied to terminals 1J-3 or 1F-10 and 1F-7
|
10 kΩ or higher
|
| Battery voltage is applied to terminals 1J-3 or 1F-10 and 1F-7
|
Below 1 Ω
|
No. 1 Integration Relay (EFI-MAIN relay)
| Standard Resistance
|
1F-10 - 1F-17
|
Battery voltage is not applied to terminals 1F-5 and 1F-17
|
10 kΩ or higher
|
| 1J-3 - 1F-17
|
| 1F-10 - 1F-17
|
Battery voltage is applied to terminals 1F-5 and 1F-17
|
Below 1 Ω
|
| 1J-3 - 1F-17
|
No. 1 Integration Relay (MGC relay)
| Standard Resistance
|
1D-7 - 1D-8
|
Battery voltage is not applied to terminals 1D-9 or 1D-10 and 1D-2
|
10 kΩ or higher
|
| Battery voltage is applied to terminals 1D-9 or 1D-10 and 1D-2
|
Below 1 Ω
|
No. 1 Integration Relay (IG1 relay)
| Standard Resistance
|
1D-9 - 1E-5
|
Battery voltage is not applied to terminals 1D-1 and 1F-18
|
10 kΩ or higher
|
| 1D-10 - 1E-5
|
| 1D-9 - 1E-5
|
Battery voltage is applied to terminals 1D-1 and 1F-18
|
Below 1 Ω
|
| 1D-10 - 1E-5
|
No. 1 Integration Relay (IG2 relay)
| Standard Resistance
|
1D-5 - 1E-5
|
Battery voltage is not applied to terminals 1D-1 and 1F-18
|
10 kΩ or higher
|
| Battery voltage is applied to terminals 1D-1 and 1F-18
|
Below 1 Ω
|
No. 1 Integration Relay (RAD/FAN NO. 1 relay)
| Standard Resistance
|
1E-1 - 1E-4
|
Battery voltage is not applied to terminals 1D-5 and 1D-6
|
10 kΩ or higher
|
| Battery voltage is applied to terminals 1D-5 and 1D-6
|
Below 1 Ω
|
No. 1 Integration Relay (RAD/FAN NO. 2 relay)
| Standard Resistance
|
1E-3 - 1E-4
|
Battery voltage is not applied to terminals 1D-5 and 1D-12
|
10 kΩ or higher
|
| Battery voltage is applied to terminals 1D-5 and 1D-12
|
Below 1 Ω
|
No. 1 Integration Relay (Fuel pump relay)
| Standard Resistance
|
1D-3 - 1D-11
|
Battery voltage is not applied to terminals 1D-4 and 1D-5
|
10 kΩ or higher
|
| Battery voltage is applied to terminals 1D-4 and 1D-5
|
Below 1 Ω
|
No. 1 Integration Relay (ST NO. 2 relay circuit)
| Standard Resistance
|
1E-6 - 3
|
Always
|
Below 1 Ω
|
| 1F-1 - 5
|
Always
|
Below 1 Ω
|
| 1F-13 - 2
|
Always
|
Below 1 Ω
|
| 1F-14 - 2
|
Always
|
Below 1 Ω
|
| 1F-15 -1
|
Always
|
Below 1 Ω
|
| 1F-16 -1
|
Always
|
Below 1 Ω
|
| 1J-4 - 5
|
Always
|
Below 1 Ω
|