CONSTRUCTION
The HV battery junction block assembly consists of the System Main Relays (SMRs), precharge resistor and battery current sensor.
The SMRs are relays that connect and disconnect the HV battery and power cable (HV floor under wire) in accordance with the signal from the hybrid vehicle control ECU. 3 relays are provided; SMRB for the battery positive (+) side, SMRG for the battery negative (-) side, and SMRP for pre-charging.
| *1 | HV Battery Junction Block Assembly | *2 | SMRB |
| *3 | SMRP | *4 | SMRG |
| *5 | Precharge Resistor | *6 | Battery Current Sensor |
| *a | The illustrations shown are examples only. | - | - |
A battery current sensor, which is built into the HV battery junction block assembly, is used to detect the HV battery charging and discharging amperage.
The hybrid vehicle control ECU optimally controls the hybrid system so that the SOC of the HV battery can always be within a specified range according to the amperage information that is received via the battery smart unit (battery voltage sensor).