Home › Engine / Hybrid System › M20A-FXS (COOLING) › COOLANT FLOW › from 2019.09
NM32K0E _51 Engine / Hybrid System _084577 M20A-FXS COOLING _0407537 COOLANT FLOW CO CONTROL F

M20A-FXS COOLING  COOLANT FLOW  CONTROL  WATER PUMP CONTROL  


FUNCTION OF MAIN COMPONENTS


Component Function
Engine Water Pump Assembly (Water Inlet Housing with Water Pump Sub-assembly) Optimizes coolant circulation based on signals from the ECM.
ECM Controls the engine water pump assembly (water inlet housing with water pump sub-assembly) by the engine conditions.
Air Conditioning Amplifier Assembly Transmits the operating state of the air conditioning system and refrigerant pressure to the ECM.


FUNCTION


a.

Since this engine is stopped and restarted repeatedly by the hybrid system, by providing an electric engine water pump assembly, coolant temperatures while the engine is operating will be stable, and shutting off the power to the pump motor will contribute to fuel economy.


b.

The ECM receives pump motor speed pulse signals from the electric water pump driver circuit, and then determines the pump motor speed so that an optimal engine coolant flow volume can be obtained according to the operating conditions.