Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2016.10–2019.09
RM32K0E _51 Engine / Hybrid System _059620 HYBRID / BATTERY CONTROL _0292486 HYBRID CONTROL SYSTEM U

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  TERMINALS OF ECU  


HYBRID VEHICLE CONTROL ECU


C297329E11
1.344,1.458 1.844,1.708 0.5,0.25 2.667,1.469 3.167,1.719 0.5,0.25 4.198,1.469 4.698,1.719 0.5,0.25 5.469,1.458 5.969,1.708 0.5,0.25 1.469,1.5 1.823,1.656 0.354,0.156 10 false A49 2.802,1.5 3.177,1.698 0.375,0.198 10 false A48 4.365,1.51 4.865,1.698 0.5,0.188 10 false F2 5.635,1.51 6.042,1.677 0.406,0.167 10 false F3

Terminal No.
(Symbol)
Wiring Color Terminal Description Input/Output Condition Specified Condition
A49-1 (+B2) - F2-6 (E1) L - W-B Power source Input Power switch on (IG) 11 to 14 V
A49-3 (IG2) - F2-6 (E1) BE - W-B Power source Input Power switch on (IG) 11 to 14 V
A49-8 (VCP2) - A49-18 (EPA2) G - W Accelerator pedal sensor assembly power source (for VPA2) Output Power switch on (IG) 4.5 to 5.5 V
A49-9 (VCPA) - A49-20 (EPA) BE - L Accelerator pedal sensor assembly power source (for VPA) Output Power switch on (IG) 4.5 to 5.5 V
A49-13 (IWP) - F2-6 (E1) G - W-B Inverter water pump with motor assembly signal Output Power switch on (READY) Pulse generation (Waveform 1)
A49-14 (NIWP) - F2-6 (E1) GR - W-B Inverter water pump with motor assembly signal Input Power switch on (READY) Pulse generation (Waveform 1)
A49-15 (STP) - F2-6 (E1) SB - W-B Stop light switch Input Brake pedal depressed 11 to 14 V
Brake pedal released 0 to 1.5 V
A49-17 (LIN3) - F2-6 (E1) Y - W-B LIN communication signal (A/C inverter, auxiliary battery) Input/Output Power switch on (READY) Pulse generation
A49-21 (TTA) - A49-31 (ETTA) V - P Transmission fluid temperature sensor Input Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
A49-22 (ACCI) - F2-6 (E1) R - W-B ACC relay Input Power switch on (ACC) 11 to 14 V
A49-24 (MMT) - A49-23 (MMTG) L - BR Motor temperature sensor Input Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
A49-26 (GMT) - A49-27 (GMTG) LG - R Generator temperature sensor Input Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
A49-28 (VPA2) - A49-18 (EPA2) B - W Accelerator pedal sensor assembly (for accelerator pedal position detection) Input Power switch on (IG), accelerator pedal released 1.0 to 2.2 V
Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed 3.4 to 5.3 V
A49-30 (VPA) - A49-20 (EPA) GR - L Accelerator pedal sensor assembly (for accelerator pedal position detection) Input Power switch on (IG), accelerator pedal released 0.4 to 1.4 V
Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed 2.6 to 4.5 V
A48-1 (PSFT) - F2-6 (E1) R - W-B Shift lever position sensor power source Output Power switch on (ACC) 11 to 14 V
A48-2 (BL) - F2-6 (E1) LG - W-B Back-up light Output Power switch on (IG), shift lever in R 11 to 14 V
A48-4 (+B1) - F2-6 (E1) L - W-B Power source Input Power switch on (IG) 11 to 14 V
A48-6 (MREL) - F2-6 (E1) BE - W-B Main relay Output Power switch on (IG) 11 to 14 V
A48-7 (IGB) - F2-6 (E1) LG - W-B Power source Input Power switch on (IG) 11 to 14 V
A48-12 (HSDN) - F2-6 (E1) B - W-B MG ECU shutdown signal Output Power switch on (READY) 0 to 1.5 V
A48-13 (ILK) - F2-6 (E1) W - W-B Interlock switch Input Power switch on (IG), service plug grip installed correctly 0 to 1.5 V
Power switch on (IG), service plug grip not installed 11 to 14 V
A48-14 (DB2) - F2-6 (E1) G - W-B Shift lever position signal Input Power switch on (IG), shift lever in D or B 6 to 14 V
Power switch on (IG), shift lever not in D or B 0 to 1.5 V
A48-15 (R) - F2-6 (E1) L - W-B Shift lever position signal Input Power switch on (IG), shift lever in R 6 to 14 V
Power switch on (IG), shift lever not in R 0 to 1.5 V
A48-17 (PR) - F2-6 (E1) GR - W-B Shift lever position signal Input Power switch on (IG), shift lever in P or R 6 to 14 V
Power switch on (IG), shift lever not in P or R 0 to 1.5 V
A48-20 (N) - F2-6 (E1) SB - W-B Shift lever position signal Input Power switch on (IG), shift lever in N 6 to 14 V
Power switch on (IG), shift lever not in N 0 to 1.5 V
A48-21 (P) - F2-6 (E1) GR - W-B Shift lever position signal Input Power switch on (IG), shift lever in P 6 to 14 V
Power switch on (IG), shift lever not in P 0 to 1.5 V
A48-26 (DB1) - F2-6 (E1) W - W-B Shift lever position signal Input Power switch on (IG), shift lever in D or B 6 to 14 V
Power switch on (IG), shift lever not in D or B 0 to 1.5 V
A48-28 (ST1-) - F2-6 (E1) R - W-B Stop light switch signal Input Power switch on (IG), brake pedal depressed 11 to 14 V
Power switch on (IG), brake pedal released 0 to 1.5 V
A48-30 (HMCL) - F2-6 (E1) W - W-B MG ECU communication request signal Input/Output Power switch on (IG) Pulse generation (Waveform 2)
A48-31 (HMCH) - F2-6 (E1) B - W-B MG ECU communication request signal Output Power switch on (IG) Pulse generation (Waveform 2)
A48-34 (PNB) - F2-6 (E1) P - W-B Shift lever position signal Input Power switch on (IG), shift lever in P, N, or B 6 to 14 V
F2-1 (SMRG) - F2-5 (E01) P - W-B System main relay operation signal Output Power switch on (IG) → Power switch on (READY) Pulse generation (Waveform 3)
F2-3 (SMRP) - F2-5 (E01) LG - W-B System main relay operation signal Output Power switch on (IG) → Power switch on (READY) Pulse generation (Waveform 3)
F2-4 (SMRB) - F2-5 (E01) BE - W-B System main relay operation signal Output Power switch on (IG) → Power switch on (READY) Pulse generation (Waveform 3)
F2-8 (INDR) - F2-6 (E1) R - W-B Shift position indicator signal Input Power switch on (IG), shift lever in R 0 to 3.2 V
Power switch on (IG), shift lever not in R 11 to 14 V
F2-9 (ST2) - F2-6 (E1) B - W-B Starter signal Input Power switch on (IG) 0 to 1.5 V
F2-32 (BTH+) - F2-6 (E1) G - W-B Communication signal from battery voltage sensor to hybrid vehicle ECU assembly Input Power switch on (IG) Pulse generation (Waveform 4)
F2-33 (BTH-) - F2-6 (E1) W - W-B Communication signal from battery voltage sensor to hybrid vehicle ECU assembly Input Power switch on (IG) Pulse generation (Waveform 4)
F3-3 (BATT) - F2-6 (E1) B - W-B Constant power source Input Power switch on (IG) 11 to 14 V
Power switch on (READY) 11 to 15.5 V
F3-7 (PLKC) - F2-6 (E1) LG - W-B Shift lock release request signal Output Power switch on (READY), brake pedal depressed 11 to 14 V
Power switch on (READY), brake pedal released 0 to 1.5 V
F3-10 (INDB) - F2-6 (E1) B - W-B Shift position indicator signal Input Power switch on (IG), shift lever in B 0 to 3.2 V
Power switch on (IG), shift lever not in B 11 to 14 V
F3-11 (INDD) - F2-6 (E1) V - W-B Shift position indicator signal Input Power switch on (IG), shift lever in D 0 to 3.2 V
Power switch on (IG), shift lever not in D 11 to 14 V
F3-12 (INDN) - F2-6 (E1) GR - W-B Shift position indicator signal Input Power switch on (IG), shift lever in N 0 to 3.2 V
Power switch on (IG), shift lever not in N 11 to 14 V
F3-13 (INDP) - F2-6 (E1) G - W-B Shift position indicator signal Input Power switch on (IG), shift lever in P 0 to 3.2 V
Power switch on (IG), shift lever not in P 11 to 14 V
F3-14 (ABFS) - F2-6 (E1) B - W-B Airbag activation signal Input Power switch on (READY) Pulse generation (Waveform 5)
F3-15 (EVSW) - F2-6 (E1) R - W-B EV drive mode switch (combination switch assembly) signal Input Power switch on (IG), EV drive mode switch (combination switch assembly) not operated 11 to 14 V
Power switch on (IG), EV drive mode switch (combination switch assembly) operated 0 to 1.5 V
F3-24 (CA1L) - F2-6 (E1) P - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation (Waveform 6)
F3-25 (CA1H) - F2-6 (E1) L - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation (Waveform 6)
F3-28 (TC) - F2-6 (E1) G - W-B Diagnosis terminal Input Power switch on (IG) 11 to 14 V
F3-29 (SI0) - F2-6 (E1) SB - W-B Battery cooling blower assembly operation signal Output Cooling fans operating Pulse generation (Waveform 7)
Cooling fans not operating 4.5 to 5.5 V
F3-30 (CA3N) - F2-6 (E1) W - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation (Waveform 8)
F3-31 (CA3P) - F2-6 (E1) R - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation (Waveform 8)

a.

Oscilloscope waveforms

HINT:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


i.
A374025E02
0.292,1.385 0.635,1.542 0.344,0.156 10 false CH2 0.313,0.656 0.771,0.854 0.458,0.198 10 false CH1 2.938,1.635 3.281,1.792 0.344,0.156 10 false GND 2.948,0.854 3.292,1.01 0.344,0.156 10 false GND

Waveform 1 (Inverter water pump assembly signal)

Item Content
Terminal CH1: A49-13 (IWP) - F2-6 (E1)
CH2: A49-14 (NIWP) - F2-6 (E1)
Equipment Setting 5 V/DIV., 20 ms./DIV.
Condition Power switch on (READY)


ii.
A284438E08
2.969,1.198 3.427,1.396 0.458,0.198 10 GND 2.969,1.573 3.427,1.771 0.458,0.198 10 GND 0.396,0.646 0.854,0.844 0.458,0.198 10 CH1 0.396,1.229 0.854,1.427 0.458,0.198 10 CH2

Waveform 2 (CAN communication signal)

Item Content
Terminal CH1: A48-31 (HMCH) - F2-6 (E1)
CH2: A48-30 (HMCL) - F2-6 (E1)
Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



iii.
C206010E19
2.958,0.656 3.292,0.896 0.333,0.24 10 false GND 2.958,1.042 3.292,1.281 0.333,0.24 10 false GND 2.958,1.427 3.292,1.667 0.333,0.24 10 false GND 0.271,0.573 0.594,0.781 0.323,0.208 10 false CH1 0.281,0.948 0.615,1.188 0.333,0.24 10 false CH2 0.292,1.313 0.625,1.552 0.333,0.24 10 false CH3

Waveform 3 (system main relay operation signal)

Item Content
Terminal CH1: F2-3 (SMRP) - F2-5 (E01)
CH2: F2-4 (SMRB) - F2-5 (E01)
CH3: F2-1 (SMRG) - F2-5 (E01)
Equipment Setting 10 V/DIV., 200 ms./DIV.
Condition Power switch on (IG) → Power switch on (READY)


iv.
A298837E02
0.313,0.771 0.635,0.948 0.323,0.177 10 CH1 0.323,1.354 0.646,1.531 0.323,0.177 10 CH2 2.99,1.042 3.354,1.24 0.365,0.198 10 GND 2.99,1.594 3.354,1.792 0.365,0.198 10 GND

Waveform 4 (communication signal from battery voltage sensor to hybrid vehicle control ECU)

Item Content
Terminal CH1: F2-32 (BTH+) - F2-6 (E1)
CH2: F2-33 (BTH-) - F2-6 (E1)
Equipment Setting 2 V/DIV., 500 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



v.
A298836E02
3.01,1.052 3.396,1.25 0.385,0.198 10 GND

Waveform 5 (airbag activation signal)

Item Content
Terminal F3-14 (ABFS) - F2-6 (E1)
Equipment Setting 5 V/DIV., 125 ms./DIV.
Condition Power switch on (READY)


vi.
A284438E09
2.969,1.198 3.427,1.396 0.458,0.198 10 GND 2.969,1.573 3.427,1.771 0.458,0.198 10 GND 0.396,0.646 0.854,0.844 0.458,0.198 10 CH1 0.396,1.229 0.854,1.427 0.458,0.198 10 CH2

Waveform 6 (CAN communication signal)

Item Content
Terminal CH1: F3-25 (CA1H) - F2-6 (E1)
CH2: F3-24 (CA1L) - F2-6 (E1)
Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



vii.
C257882E03
2.99,1.052 3.396,1.292 0.406,0.24 10 false GND

Waveform 7 (HV battery blower fan operation signal)

Item Content
Terminal F3-29 (SI0) - F2-6 (E1)
Equipment Setting 10 V/DIV., 1 ms./DIV.
Condition Cooling fans operating

HINT:

The waveform will vary with the operating speed of the battery cooling blower assembly.



viii.
A284438E10
2.969,1.198 3.427,1.396 0.458,0.198 10 GND 2.969,1.573 3.427,1.771 0.458,0.198 10 GND 0.396,0.646 0.854,0.844 0.458,0.198 10 CH1 0.396,1.229 0.854,1.427 0.458,0.198 10 CH2

Waveform 8 (CAN communication signal)

Item Content
Terminal CH1: F3-31 (CA3P) - F2-6 (E1)
CH2: F3-30 (CA3N) - F2-6 (E1)
Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).





BATTERY VOLTAGE SENSOR


A368663E03
1.469,3.031 1.896,3.26 0.427,0.229 4.656,3.031 5.083,3.26 0.427,0.229 5.875,3.021 6.302,3.25 0.427,0.229 1.604,3.083 1.917,3.281 0.313,0.198 10 false z8 4.771,3.073 5.313,3.229 0.542,0.156 10 false z12 5.948,3.052 6.292,3.229 0.344,0.177 10 false M41

Terminal No.
(Symbol)
Wiring Color Terminal Description Input/Output Condition Specified Condition
z12-1 (TC0) - z12-7 (GC0) G - G Intake air temperature sensor Input HV battery intake air temperature: -40 to 90°C (-40 to 194°F) 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F))
z12-2 (TB2) - z12-8 (GB2) R - R Battery temperature sensor 2 Input HV battery temperature: -40 to 90°C (-40 to 194°F) 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F))
z12-3 (TB1) - z12-9 (GB1) W - W Battery temperature sensor 1 Input HV battery temperature: -40 to 90°C (-40 to 194°F) 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F))
z12-4 (TB0) - z12-10 (GB0) L - L Battery temperature sensor 0 Input HV battery temperature: -40 to 90°C (-40 to 194°F) 4.8 (-40°C (-40°F)) to 1.0 V (90°C (194°F))
z12-5 (IB0) - z12-12 (GIB) Y - B Current sensor Input Power switch on (READY) 0.5 to 4.5 V
z12-6 (VIB) - z12-12 (GIB) BR - B Power source for battery current sensor Output Power switch on (IG) 4.5 to 5.5 V
M41-1 (IGCT) - M41-5 (GND) SB - W-B Control signal Input Power switch on (READY) 11 to 14 V
M41-2 (BTH+) - M41-5 (GND) R - W-B Serial communication Output Power switch on (IG) Pulse generation
(waveform 1)
M41-3 (BTH-) - M41-5 (GND) W - W-B Serial communication Output Power switch on (IG) Pulse generation
(waveform 2)
M41-5 (GND) - Body ground W-B - Body ground Ground - Always (continuity check) Below 1 Ω
M41-8 (FP0) - M41-5 (GND) B - W-B Battery cooling blower No. 0 monitor signal Input Cooling blower stopped 0 Hz
Cooling blower activated Pulse generation
(waveform 3)

a.

Oscilloscope waveforms

HINT:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


i.
A284561E09
2.99,1.219 3.396,1.417 0.406,0.198 10 GND

Waveform 1 (Serial communication)

Item Content
Terminal M41-2 (BTH+) - M41-5 (GND)
Equipment Setting 2 V/DIV., 500 μs/DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



ii.
A284562E08
2.99,1.229 3.396,1.438 0.406,0.208 10 GND

Waveform 2 (Serial communication)

Item Content
Terminal M41-3 (BTH-) - M41-5 (GND)
Equipment Setting 2 V/DIV., 500 μs/DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



iii.
A284436E08
2.938,1.031 3.396,1.229 0.458,0.198 10 false GND

Waveform 3 (Battery cooling blower No. 0 monitor signal)

Item Content
Terminal M41-8 (FP0) - M41-5 (GND)
Equipment Setting 2 V/DIV., 2 ms/DIV.
Condition Battery cooling blower assembly (No. 0) operating (Active Test of cooling fan being performed)

HINT:

The frequency of the waveform will vary with the operating speed of the battery cooling blower assembly (No. 0).