Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2016.10–2018.05
RM32K0E _51 Engine / Hybrid System _059620 HYBRID / BATTERY CONTROL _0292486 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P1A8000  Hybrid/EV Battery Stack 1 Delta SOC High  P1AD01B  Hybrid/EV Battery Block Circuit Resistance Above Threshold  


DESCRIPTION

The battery voltage sensor and the hybrid vehicle control ECU calculate the SOC (state of charge) of the HV battery through the accumulated amperage in the HV battery. The battery voltage sensor sends the condition of the HV battery to the hybrid vehicle control ECU. Then the hybrid vehicle control ECU calculates the SOC based on the information and controls the charging and discharging of the HV battery based to the driving condition.

Based on the HV battery voltage and current, the battery voltage sensor calculates the resistance and judges if the HV battery has deteriorated.

A171602E09
4.333,0.813 4.729,0.813 false 3.521,0.802 3.854,0.458 false 4.24,1.969 4.469,1.969 false 2.656,0.813 2.24,0.813 false 3.51,1.958 3.813,2.292 false 4.781,0.719 6.531,0.885 1.75,0.167 10 false Example of Change in SOC 3.906,0.354 5.615,0.521 1.708,0.167 10 false Upper SOC Control Limit 3.875,2.198 5.573,2.365 1.698,0.167 10 false Lower SOC Control Limit 4.531,1.865 5.76,2.031 1.229,0.167 10 false Central SOC Level 1.281,0.698 2.281,0.917 1,0.219 10 false Control Region 2.813,1.896 3.188,2.063 0.375,0.167 10 false Time 2.063,1.198 2.406,1.365 0.344,0.167 10 false SOC

A369302E04
2.042,6.958 2.552,7.229 0.51,0.271 10 false VB1 2.042,6.427 2.583,6.771 0.542,0.344 10 false VB2 2.021,2.688 2.573,3.083 0.552,0.396 10 false VB10 2.052,3.646 2.594,3.979 0.542,0.333 10 false VB8 2.042,5.5 2.594,6.052 0.552,0.552 10 false VB4 2.042,1.75 2.604,2.177 0.563,0.427 10 false VB12 2.052,4.583 2.625,4.958 0.573,0.375 10 false VB6 2.031,1.229 2.635,1.583 0.604,0.354 10 false VB13 2.021,0.688 2.563,1.021 0.542,0.333 10 false VB14 2.615,0.979 4.208,1.469 1.594,0.49 10 false Connected to circuit B 2.635,1.5 4.229,1.99 1.594,0.49 10 false Connected to circuit A 2.635,2.24 4.229,2.729 1.594,0.49 10 false Connected to circuit C 2.635,3.188 4.229,3.677 1.594,0.49 10 false Connected to circuit C 2.625,4.125 4.104,4.375 1.479,0.25 10 false Connected to circuit C 2.635,5.052 4.229,5.542 1.594,0.49 10 false Connected to circuit C 2.635,6.719 4.229,7.208 1.594,0.49 10 false Connected to circuit B 2.635,5.99 4.229,6.479 1.594,0.49 10 false Connected to circuit C 2.625,7.24 4.219,7.729 1.594,0.49 10 false Connected to circuit A 4.01,3.75 4.625,4.344 0.615,0.594 10 false Circuit A 4.01,4.313 4.625,4.906 0.615,0.594 10 false Circuit B 4.021,5.167 4.635,5.76 0.615,0.594 10 false Circuit C 5.781,5.563 6.917,6.24 1.135,0.677 10 false Analogue/Digital 5.781,5.729 6.917,6.406 1.135,0.677 10 false Converter Circuit 1.813,7.865 4.021,8.365 2.208,0.5 10 false Voltage Detection Relay Circuit 2.052,8.396 3.615,8.76 1.563,0.365 10 false Battery Voltage Sensor 2.031,7.5 2.542,7.771 0.51,0.271 10 false GB0 0.135,7.354 1.177,7.948 1.042,0.594 10 false Block 1 Voltage 0.135,6.833 1.177,7.427 1.042,0.594 10 false Block 2 Voltage 0.156,6.146 1.198,6.74 1.042,0.594 10 false Block 3 Voltage 0.167,5.167 1.208,5.76 1.042,0.594 10 false Block 4 Voltage 0.135,4.26 1.177,4.854 1.042,0.594 10 false Block 5 Voltage 0.167,3.271 1.208,3.865 1.042,0.594 10 false Block 6 Voltage 0.146,2.396 1.188,2.99 1.042,0.594 10 false Block 7 Voltage 0.146,1.688 1.135,2.313 0.99,0.625 10 false Block 8 Voltage 0.146,0.969 1.292,1.646 1.146,0.677 10 false Block 9 Voltage 0.156,0.802 1.302,1.479 1.146,0.677 10 false Hybrid Battery 0.156,1.51 1.302,2.188 1.146,0.677 10 false Hybrid Battery 0.167,3.094 1.313,3.771 1.146,0.677 10 false Hybrid Battery 0.156,2.219 1.302,2.896 1.146,0.677 10 false Hybrid Battery 0.135,4.094 1.281,4.771 1.146,0.677 10 false Hybrid Battery 0.156,5.031 1.302,5.708 1.146,0.677 10 false Hybrid Battery 0.156,5.979 1.302,6.656 1.146,0.677 10 false Hybrid Battery 0.135,6.667 1.281,7.344 1.146,0.677 10 false Hybrid Battery 0.135,7.188 1.281,7.865 1.146,0.677 10 false Hybrid Battery

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P1A8000 Hybrid/EV Battery Stack 1 Delta SOC High Difference in capacity between each battery block is larger than standard.
(2 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P1AD01B Hybrid/EV Battery Block Circuit Resistance Above Threshold Resistance of an HV battery block exceeds the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on

Related Data List
DTC No. Data List
P1A8000
·

Internal Resistance 1 to 9

·

Hybrid Battery Block 1 to 9 Voltage *1

·

Hybrid Battery SOC


P1AD01B

HINT:
·

*1: Under normal conditions, the values of Hybrid Battery Block 1, 2, 8 and 9 Voltage will be approximately 16 V and Hybrid Battery Block 3, 4, 5, 6 and 7 Voltage will be approximately 32 V.

·

If there is a short or open in a battery block voltage detection line, the value of Hybrid Battery Block Voltage for the corresponding battery block will be lower than 8 V.



The following items can be helpful when performing repairs:

Data List
·

Ready Signal

·

Vehicle Speed

·

Accelerator Position

·

Shift Position

·

Engine Speed

·

Hybrid Battery Voltage

·

Hybrid Battery Current

·

BATT Voltage

·

Hybrid Battery SOC just after IG-ON

·

Hybrid Battery Maximum SOC

·

Hybrid Battery Minimum SOC

·

Total Distance Traveled

·

Distance from DTC Cleared

·

Engine Run Time


Vehicle Control History Data

Hybrid Battery Voltage Low


HINT:
·

This DTC can be stored after clearing DTCs and driving the vehicle for approximately 10 minutes. (As 2 trip detection logic is also used, check for DTCs including pending DTCs.)

·

When the internal resistance of the HV battery increases, battery block voltage may drop.

·

If resistance is abnormal, the voltage of the battery blocks indicated by the DTCs are likely to decrease more than others during acceleration (discharging), and increase more during deceleration (charging).

·

In order to ensure HV battery performance, appropriate cooling performance must be maintained. Perform the following items as necessary. If cooling performance has decreased and "Hybrid Battery Cooling Warning" is displayed on the multi-information display, make sure to perform the following items:

-

Make sure the air intake port is not blocked.

-

Make sure there are no gaps between the connecting parts of the ducts.

-

Clean the No. 1 HV battery intake filter.

Clear the DTCs to reset the learning values even if no DTCs are stored.





CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Drive the vehicle on urban roads at a speed of 25 mph (40 km/h) or more for a total of at least 10 minutes. (It is not necessary to maintain the vehicle speed at 40 km/h (25 mph) throughout the road test.)

HINT:

This DTC may not be stored if the vehicle is stopped or being driven at a steady speed.


7.

Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A358021C02
0.531,4.146 0.844,4.344 0.313,0.198 10 false *a 2.74,4.146 3.052,4.344 0.313,0.198 10 false *b
*a Dealer
*b Battery Collection Agent


When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

-

Accidents such as electric shock may result if the HV battery is disposed of improperly or abandoned. Therefore, make sure to return all HV batteries through an authorized collection agent.



·
A358020

After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.



PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check and record any HV system DTCs and freeze frame data.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Result:
Result Proceed to
P0AFC00, P0AFC96, P308A12 or P0AFC62 is not output. A
P0AFC00, P0AFC96, P308A12 or P0AFC62 is also output. B



e.

Turn the power switch off.



A

2.CHECK TOTAL DISTANCE DRIVEN

B

2.CHECK TOTAL DISTANCE DRIVEN
a.

Read the odometer to check the total distance the vehicle has been driven.

Result:
Result Proceed to
Total distance driven is less than 200000 km (124280 mile) A
Total distance driven is 200000 km (124280 mile) or more Current total distance driven - total distance driven when hybrid battery terminal block replaced = less than 200000 km (124280 mile) *1
Other than above B


HINT:

*1: If the hybrid battery terminal block has been replaced, use the total distance driven since it was replaced.




A

B

3.REPLACE HV BATTERY
3.REPLACE HV BATTERY

NEXT

REPLACE HYBRID BATTERY TERMINAL BLOCK