MALFUNCTION DESCRIPTION
These DTCs indicate that the current sensor value is abnormal. The cause of this malfunction may be one of the following:
Inverter with converter assembly internal circuit malfunction
The connectors are not connected properly
The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors the motor inverter current sensor. These DTCs indicate the malfunction of current sensors and do not indicate a malfunction of the high-voltage system.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0BE512 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery | Malfunction in motor inverter current sensor (phase U main sensor)
(Short to +B) (1 trip detection logic) |
·
Inverter with converter assembly ·
Wire harness or connector |
Comes on | Master Warning Light:
Comes on |
| P0BE514 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open | Malfunction in motor inverter current sensor (phase U main sensor)
(Open or short to ground) (1 trip detection logic) |
·
Inverter with converter assembly ·
Wire harness or connector |
Comes on | Master Warning Light:
Comes on |
| P0BE51F | Drive Motor "A" Phase U Current Sensor Circuit Intermittent | Short to +B, open or short to ground detected in motor inverter current sensor (phase U main sensor) when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic) |
·
Inverter with converter assembly ·
Wire harness or connector |
Does not come on | Master Warning Light:
Does not come on |
| P0BE912 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery | Malfunction in motor inverter current sensor (phase V main sensor)
(Short to +B) (1 trip detection logic) |
·
Inverter with converter assembly ·
Wire harness or connector |
Comes on | Master Warning Light:
Comes on |
| P0BE914 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open | Malfunction in motor inverter current sensor (phase V main sensor)
(Open or short to ground) (1 trip detection logic) |
·
Inverter with converter assembly ·
Wire harness or connector |
Comes on | Master Warning Light:
Comes on |
| P0BE91F | Drive Motor "A" Phase V Current Sensor Circuit Intermittent | Short to +B, open or short to ground detected in motor inverter current sensor (phase V main sensor) when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic) |
·
Inverter with converter assembly ·
Wire harness or connector |
Does not come on | Master Warning Light:
Does not come on |
| P0BED12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery | Malfunction in motor inverter current sensor (phase W main sensor)
(Short to +B) (1 trip detection logic) |
·
Inverter with converter assembly ·
Wire harness or connector |
Comes on | Master Warning Light:
Comes on |
| P0BED14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open | Malfunction in motor inverter current sensor (phase W main sensor)
(Open or short to ground) (1 trip detection logic) |
·
Inverter with converter assembly ·
Wire harness or connector |
Comes on | Master Warning Light:
Comes on |
| P0BED1F | Drive Motor "A" Phase W Current Sensor Circuit Intermittent | Short to +B, open or short to ground detected in motor inverter current sensor (phase W main sensor) when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic) |
·
Inverter with converter assembly ·
Wire harness or connector |
Does not come on | Master Warning Light:
Does not come on |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
With power switch on (IG) and wait for 5 seconds or more.
Turn the power switch on (READY) with the shift lever in P and wait for 5 seconds or more.
Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine.
Drive the vehicle forward with the shift lever in D for 5 m (16 ft.) or more.
Drive the vehicle backward with the shift lever in R 5 m (16 ft.) or more.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Motor Generator / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0BE512, P0BE514, P0BE51F, P0BE912, P0BE914, P0BE91F, P0BED12, P0BED14 and P0BED1F only is output, or DTCs except the ones in the table below are also output. | A |
| Any of the following DTCs including pending DTCs are also output. | B |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Power source circuit malfunction | P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06D61C | Sensor Reference Voltage "F" Circuit / Open | |
| System malfunction | P0A7873 | Drive Motor "A" Inverter Actuator Stuck Closed |
P0BE512, P0BE514, P0BE51F, P0BE912, P0BE914, P0BE91F, P0BED12, P0BED14 and P0BED1F may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Turn the power switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P033500
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C