Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM › 2016.10–2020.08
RM32K0E _57 Power Source / Network _059857 NETWORKING _0293867 CAN COMMUNICATION SYSTEM J

NETWORKING  CAN COMMUNICATION SYSTEM  Combination Meter ECU Communication Stop Mode  


DESCRIPTION

Detection Item Symptom Trouble Area
Combination Meter ECU Communication Stop Mode Any of the following conditions are met:
·

Communication stop for "Combination Meter" is indicated on the "Communication Bus Check" screen of the GTS.

Click here(Click here)

·

Communication stop history for "Combination Meter" is indicated on the "Communication Bus Check (Detail)" screen of the GTS. (The Lost Communication Time value for "Combination Meter" is 6 or more.)

Click here(Click here)

·

Communication system DTCs (DTCs that start with U) that correspond to "Combination Meter ECU Communication Stop Mode" in "DTC Combination Table" are output.

Click here(Click here)


·

Combination meter assembly main line or connector

·

Power source circuit of combination meter assembly

·

Combination meter assembly ground circuit

·

Combination meter assembly



WIRING DIAGRAM

C366182E08
1.667,0.51 1.823,0.708 0.156,0.198 10 false 1 1.677,1.073 1.927,1.271 0.25,0.198 10 false 12 5.521,0.521 5.771,0.719 0.25,0.198 10 false 32 5.521,1.052 5.771,1.25 0.25,0.198 10 false 31 5.813,0.552 6.313,0.75 0.5,0.198 10 false CANH 5.813,1.26 6.313,1.458 0.5,0.198 10 false CANL 5.833,2.229 6.333,2.427 0.5,0.198 10 false IG+ 5.833,2.813 6.333,3.01 0.5,0.198 10 false B 5.833,3.292 6.333,3.49 0.5,0.198 10 false ET 5.521,2.135 5.771,2.333 0.25,0.198 10 false 39 5.531,2.667 5.781,2.865 0.25,0.198 10 false 40 5.51,3.208 5.76,3.406 0.25,0.198 10 false 21 5.583,3.667 5.833,3.865 0.25,0.198 10 false F4 5.583,3.844 6.75,4.26 1.167,0.417 10 false Combination Meter Assembly 4.427,2.385 5.344,2.583 0.917,0.198 10 false METER-IG2 4.292,2.917 5.458,3.083 1.167,0.167 10 false ECU-DCC NO. 2 2.125,2.229 3.708,2.479 1.583,0.25 10 false from IG2-NO. 2 Relay 2.135,2.75 3.719,3 1.583,0.25 10 false from Auxiliary Battery 0.177,1.583 0.844,1.75 0.667,0.167 10 false F114 0.177,1.75 2.177,1.917 2,0.167 10 false No. 3 CAN Junction Connector

CAUTION / NOTICE / HINT

NOTICE:
·

Because the order of diagnosis is important to allow correct diagnosis, make sure to begin troubleshooting using How to Proceed with Troubleshooting when CAN communication system related DTCs are output.

Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING

·

Before measuring the resistance of the CAN bus, turn the power switch off and leave the vehicle for 1 minute or more without operating the key or any switches, or opening or closing the doors. After that, disconnect the cable from the negative (-) auxiliary battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.

·

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

After performing repairs, perform the DTC check procedure and confirm that the DTCs are not output again.

DTC check procedure: Turn the LDA main switch on and then drive the vehicle at a speed of 1 km/h (1 mph) or more for approximately 52 seconds or more.

·

After the repair, perform the CAN bus check and check that all the ECUs and sensors connected to the CAN communication system are displayed as normal.

Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>DIAGNOSIS SYSTEM

·

Inspect the fuses for circuits related to this system before performing the following procedure.

·

When replacing the combination meter assembly, always replace it with a new one. If a combination meter assembly which was installed to another vehicle is used, the information stored in it will not match the information from the vehicle and a DTC may be stored.



HINT:
·

Before disconnecting related connectors for inspection, push in on each connector body to check that the connector is not loose or disconnected.

·

When a connector is disconnected, check that the terminals and connector body are not cracked, deformed or corroded.



PROCEDURE

1.CHECK FOR OPEN IN CAN BUS LINES (COMBINATION METER ASSEMBLY MAIN LINE)
a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the combination meter assembly connector.


c.
C328874C21
1.458,0.167 1.958,0.417 0.5,0.25 1.75,1.344 1.396,1.833 true 1.958,1.344 2.323,1.865 true 0.083,0.073 0.396,0.229 0.313,0.156 10 false *a 1.646,0.219 1.958,0.375 0.313,0.156 10 false F4 1.073,1.854 1.521,2.01 0.448,0.156 10 false CANL 2.323,1.875 2.771,2.031 0.448,0.156 10 false CANH
*a Front view of wire harness connector
(to Combination Meter Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F4-32 (CANH) - F4-31 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω



Result:
Result
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)

NG

REPAIR OR REPLACE CAN MAIN BUS LINES OR CONNECTOR (COMBINATION METER ASSEMBLY)

2.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
a.
C328874C22
1.448,0.24 1.948,0.49 0.5,0.25 2.708,1.833 2.854,1.354 true 3.188,1.823 3.021,1.354 true 0.542,1.865 0.406,1.344 true 0.104,0.052 0.417,0.208 0.313,0.156 10 false *a 1.615,0.271 1.927,0.438 0.313,0.167 10 false F4 2.625,1.865 2.938,2.031 0.313,0.167 10 false IG+ 3.156,1.854 3.354,2.042 0.198,0.188 10 false B 0.448,1.896 0.719,2.063 0.271,0.167 10 false ET
*a Front view of wire harness connector
(to Combination Meter Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F4-21 (ET) - Body ground Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω



b.

Reconnect the cable to the negative (-) auxiliary battery terminal.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
F4-40 (B) - Body ground Power switch off 11 to 14 V
F4-39 (IG+) - Body ground Power switch on (IG) 11 to 14 V



Result:
Result
OK
NG



OK

REPLACE COMBINATION METER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE CIRCUIT)