| Detection Item | Symptom | Trouble Area |
|---|---|---|
| Blind Spot Monitor Sensor Communication Stop Mode | Any of the following conditions are met:
·
·
|
·
Blind spot monitor sensor LH branch line or connector ·
Power source circuit of blind spot monitor sensor LH ·
Blind spot monitor sensor LH ground circuit ·
Blind spot monitor sensor LH |
Because the order of diagnosis is important to allow correct diagnosis, make sure to begin troubleshooting using How to Proceed with Troubleshooting when CAN communication system related DTCs are output.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
Before measuring the resistance of the CAN bus, turn the power switch off and leave the vehicle for 1 minute or more without operating the key or any switches, or opening or closing the doors. After that, disconnect the cable from the negative (-) auxiliary battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
After performing repairs, perform the DTC check procedure and confirm that the DTCs are not output again.
DTC check procedure: Turn the power switch on (IG), blind spot monitor system on using the blind spot monitor main switch (ON/OFF switch) and wait for approximately 12 seconds or more.
After the repair, perform the CAN bus check and check that all the ECUs and sensors connected to the CAN communication system are displayed as normal.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>DIAGNOSIS SYSTEM
Inspect the fuses for circuits related to this system before performing the following procedure.
Before disconnecting related connectors for inspection, push in on each connector body to check that the connector is not loose or disconnected.
When a connector is disconnected, check that the terminals and connector body are not cracked, deformed or corroded.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the blind spot monitor sensor LH connector.
| *a | Front view of wire harness connector
(to Blind Spot Monitor Sensor LH) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M62-2 (CA1P) - M62-7 (CA1N) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| Result |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Blind Spot Monitor Sensor LH) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M62-10 (BLGD) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | Below 1 Ω |
Reconnect the cable to the negative (-) auxiliary battery terminal.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| M62-5 (BLB) - Body ground | Power switch on (IG) | 11 to 14 V |
| Result |
|---|
| OK |
| NG |
OK
NG