85910A
1.INSPECT CIRCUIT OPENING RELAY ASSEMBLY (C/OPN)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the circuit opening relay assembly (C/OPN).
16100P
2.INSPECT WATER PUMP RELAY (ENG W/PMP)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the water pump relay (ENG W/PMP).