Home › Power Source / Network › NETWORKING › NETWORK GATEWAY ECU(for LHD)
RM32K0E _57 Power Source / Network _059857 NETWORKING _0298008 NETWORK GATEWAY ECU(for LHD) A

NETWORKING  NETWORK GATEWAY ECU(for LHD)  REMOVAL  


PROCEDURE

Hide 55433B 1.REMOVE NO. 2 INSTRUMENT PANEL LOWER FINISH PANEL

Hide 82877 2.REMOVE ECU INTEGRATION BOX RH

a.
E357156

Disconnect the 7 connectors.


b.

Disengage the clamps.


c.
E357157

Remove the bolt, 2 nuts and ECU integration box RH.


Hide 89111 3.REMOVE CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU)

a.

Disengage the claws to remove the central gateway ECU (network gateway ECU).

E357158

NOTICE:
·

If the ECU integration box RH is deformed or damaged, replace it.

·