Home › Engine / Hybrid System › 2ZR-FXE (COOLING) › FLOW SHUTTING VALVE
RM32K0E _51 Engine / Hybrid System _060780 2ZR-FXE COOLING _0298028 FLOW SHUTTING VALVE G

2ZR-FXE COOLING  FLOW SHUTTING VALVE  INSPECTION  


PROCEDURE

Hide 16671 1.INSPECT FLOW SHUTTING VALVE (WATER VALVE)

a.

Visually check the flow shutting valve (water valve).

If the flow shutting valve (water valve) is damaged, replace the flow shutting valve (water valve).


b.

Check the flow shutting valve (water valve) for clogging.

If the flow shutting valve (water valve) is clogged, check if there is foreign matter inside the flow shutting valve (water valve). Clean or replace the flow shutting valve (water valve) as necessary.


c.

Push in the valve and check that it returns quickly to its original position.

If the valve does not operate as specified, check if there is foreign matter inside the flow shutting valve (water valve). Clean or replace the flow shutting valve (water valve) as necessary.


d.
A375619C01
3.063,0.99 3.375,1.24 0.313,0.25 10 false *a
*a Valve Lift


Check the valve lift.

Standard Valve Lift:

7.9 to 8.8 mm (0.311 to 0.346 in.)


If the result is not as specified, replace the flow shutting valve (water valve).


e.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 14 to 16 Ω


If the result is not as specified, replace the flow shutting valve (water valve).