Home › Drivetrain › P610 (HYBRID TRANSMISSION / TRANSAXLE) › SHIFT LEVER
RM32K0E _52 Drivetrain _059722 P610 HYBRID TRANSMISSION / TRANSAXLE _0293793 SHIFT LEVER G

P610 HYBRID TRANSMISSION / TRANSAXLE  SHIFT LEVER  INSPECTION  


PROCEDURE

Hide 33560 1.INSPECT SHIFT LOCK CONTROL UNIT ASSEMBLY

HINT:

If the results of the following inspections are as specified but a malfunction has occurred, replace the shift lock control unit assembly.


a.

Inspect the wire harness.

i.
C365111

Disconnect the shift lock control ECU connector.


ii.
C333432C01
2.427,1.75 1.896,1.292 true 2.615,1.198 2.115,1.198 true 0.083,0.083 0.396,0.281 0.313,0.198 10 false *a 2.677,1.135 2.99,1.333 0.313,0.198 10 false IG 2.49,1.708 2.948,1.906 0.458,0.198 10 false STP
*a Front view of wire harness connector
(to Shift Lock Control ECU (Shift Lock Control Unit Assembly))


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
5 (IG) - Body ground Power switch on (IG) 11 to 14 V
Power switch off Below 1 V
4 (STP) - Body ground Brake pedal depressed 11 to 14 V
Brake pedal released Below 1 V


If the result is not as specified, repair or replace the wire harness or connector.


iii.
C333432C02
0.792,1.198 1.292,1.198 true 0.083,0.083 0.396,0.281 0.313,0.198 10 false *a 0.677,1.135 0.906,1.333 0.229,0.198 10 false E
*a Front view of wire harness connector
(to Shift Lock Control ECU (Shift Lock Control Unit Assembly))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (E) - Body ground Always Below 1 Ω


If the result is not as specified, repair or replace the wire harness or connector.



b.

Inspect the shift lock solenoid.

i.
C366439

Disconnect the shift lock solenoid connector.


ii.
C197452C44
0.802,1.521 1.365,1.25 true 1.135,1.802 1.594,1.25 true 2.063,1.25 2.615,1.542 true 2.281,1.802 1.844,1.25 true 0.083,0.083 0.292,0.271 0.208,0.188 10 false *a 2.677,1.5 2.833,1.698 0.156,0.198 10 false P 2.333,1.74 2.583,1.927 0.25,0.188 10 false E2 0.771,1.75 1.198,1.938 0.427,0.188 10 false SLS- 0.438,1.469 0.885,1.667 0.448,0.198 10 false SLS+
*a Component without harness connected
(Shift Lock Solenoid (Shift Lock Control Unit Assembly))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (SLS+) - 2 (SLS-) Always 112 Ω
4 (P) - 3 (E2) Shift lever in P 10 kΩ or higher
Shift lever not in P Below 1 Ω


If the result is not as specified, replace the shift lock control unit assembly.



Hide 2.INSPECT TRANSMISSION CONTROL SWITCH (SHIFT LOCK CONTROL UNIT ASSEMBLY) (for LHD)

a.
C365112

Disconnect the connector from the shift lock control unit assembly.


b.
C271753C07
1.906,1.083 2.198,0.375 true 2.417,1.875 2.083,1.198 true 1.438,1.906 1.729,1.198 true 0.052,0.052 0.26,0.25 0.208,0.198 10 false *a 2.24,0.271 2.396,0.438 0.156,0.167 10 false E 1.115,1.896 1.542,2.073 0.427,0.177 10 false SFTU 2.417,1.896 2.833,2.083 0.417,0.188 10 false SFTD
*a Component without harness connected
(Transmission Control Switch (Shift Lock Control Unit Assembly))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (SFTD) - 2 (E) Shift lever held in "-"(Downshift) Below 1 Ω
Shift lever not in "-" 10 kΩ or higher
3 (SFTU) - 2 (E) Shift lever held in "+"(Upshift) Below 1 Ω
Shift lever not in "+" 10 kΩ or higher


If the result is not as specified, replace the shift lock control unit assembly.


Hide 3.INSPECT TRANSMISSION CONTROL SWITCH (SHIFT LOCK CONTROL UNIT ASSEMBLY) (for RHD)

a.
C366467

Disconnect the transmission control switch connector.


b.
C271753C06
1.906,1.083 2.198,0.375 true 2.417,1.875 2.083,1.198 true 1.438,1.906 1.729,1.198 true 0.052,0.052 0.26,0.25 0.208,0.198 10 false *a 2.24,0.271 2.396,0.438 0.156,0.167 10 false E 2.458,1.885 2.885,2.063 0.427,0.177 10 false SFTU 1.073,1.865 1.49,2.052 0.417,0.188 10 false SFTD
*a Component without harness connected
(Transmission Control Switch (Shift Lock Control Unit Assembly))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 (SFTD) - 2 (E) Shift lever held in "-"(Downshift) Below 1 Ω
Shift lever not in "-" 10 kΩ or higher
1 (SFTU) - 2 (E) Shift lever held in "+"(Upshift) Below 1 Ω
Shift lever not in "+" 10 kΩ or higher


If the result is not as specified, replace the shift lock control unit assembly.