Home › General › MAINTENANCE › COOLANT (for Inverter Coolant) › 2016.10–2019.09
RM32K0E _V1 General _059911 MAINTENANCE _0294248 COOLANT(for Inverter Coolant) A

MAINTENANCE  COOLANT(for Inverter Coolant)  REPLACEMENT  


CAUTION / NOTICE / HINT

CAUTION:
·

When coolant (for inverter) is hot, do not remove the reserve tank cap or the drain cock plug.

·

Fluid and steam may spray out due to high pressure, possibly resulting in burns.

A387520C01
4.708,1.885 4.875,1.885 4.875,1.885 5.115,1.354 true 6,4.146 5.833,4.146 5.833,4.146 5.552,3.552 true 4.469,1.792 4.677,1.958 0.208,0.167 10 true *1 6.01,4.031 6.26,4.24 0.25,0.208 10 true *2
*1 Reserve Tank Cap *2 Drain Cock Plug




PROCEDURE

Hide 51444A 1.REMOVE REAR ENGINE UNDER COVER LH

a.
A387522

Remove the 2 screws, 6 clips and rear engine under cover LH.


Hide 2.DRAIN COOLANT (for Inverter)

CAUTION:
·

When coolant (for inverter) is hot, do not remove the reserve tank cap or the drain cock plug.

·

Fluid and steam may spray out due to high pressure, possibly resulting in burns.

A387520C01
4.708,1.885 4.875,1.885 4.875,1.885 5.115,1.354 true 6,4.146 5.833,4.146 5.833,4.146 5.552,3.552 true 4.469,1.792 4.677,1.958 0.208,0.167 10 true *1 6.01,4.031 6.26,4.24 0.25,0.208 10 true *2
*1 Reserve Tank Cap *2 Drain Cock Plug




NOTICE:
·

Do not reuse the drained coolant because it may contain foreign matter.

·

Collect the drained coolant and measure its volume to establish a benchmark. When adding coolant, make sure to add more coolant than the measured amount.



a.

Remove the reserve tank cap from the inverter reserve tank assembly.


b.
A387523C01
1.156,1.167 1.656,1.167 false 0.938,1.052 1.25,1.208 0.313,0.156 10 false *a
*a Hose


Connect a hose with an inside diameter of 9 mm (0.354 in.) to the radiator drain cock as shown in the illustration.


c.
A387521

Loosen the drain cock plug indicated in the illustration and drain the coolant.


d.

Tighten the drain cock plug by hand.


e.

Disconnect the hose from the radiator drain cock.


Hide 3.ADD COOLANT (for Inverter)

NOTICE:
·

Do not reuse the drained coolant because it may contain foreign matter.

·

If the vehicle is driven with air in the inverter cooling system, damage may occur and the following DTCs may be stored.

DTC No. Detection Item
P0A9300 Inverter "A" Cooling System Performance
P0C7396 Motor Electronics Coolant Pump "A" Component Internal Failure
P0A001C Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range
P0A001F Motor Electronics Coolant Temperature Sensor Circuit Intermittent
P0A789E Drive Motor "A" Inverter Stuck On
P1C5D19 Drive Motor "A" Inverter Circuit Current Above Threshold
P0A7A9E Generator Inverter Stuck On
P1C5F19 Generator Inverter Circuit Current Above Threshold
P0A949E DC/DC Converter Stuck On
P0D3319 DC/DC Converter Circuit Current Above Threshold
P0AED1C Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range
P0AED1F Drive Motor Inverter Temperature Sensor "A" Circuit Intermittent
P0C381C DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range
P0C381F DC/DC Converter Temperature Sensor "A" Circuit Intermittent
P0C3D1C DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range
P0C3D1F DC/DC Converter Temperature Sensor "B" Circuit Intermittent
P1CCC96 DC/DC Converter Enable Component Internal Failure



a.
A371710

Slowly pour coolant into the inverter reserve tank assembly until it reaches the FULL line.

Standard Capacity:

1.4 liters (1.5 US qts, 1.3 Imp. qts)


NOTICE:

To prevent foreign matter such as dust or dirt from entering the cooling system, make sure to confirm that the container used to add coolant is clean and free of foreign matter.



b.

When using the GTS:

i.

Connect the GTS to the DLC3.


ii.

Turn the power switch on (IG).


iii.

Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Inverter Water Pump.

Powertrain > Hybrid Control > Active Test
Tester Display
Activate the Inverter Water Pump
50004 397 1

iv.

While adding coolant to the inverter reserve tank assembly to keep the coolant at the FULL line and compensate for the drop in the coolant level as the air bleeds, operate and stop the inverter water pump with motor assembly at 1 minute intervals.

Standard:

Air bleeding from the inverter cooling system is completed when the noise made by the inverter water pump with motor assembly becomes smaller and the circulation of coolant in the inverter reserve tank assembly improves.


HINT:

Loud noises made by the inverter water pump with motor assembly and poor circulation of coolant in the inverter reserve tank assembly indicate that there is air in the cooling system.




c.

When not using the GTS:

i.

Turn the power switch on (READY). [*1]


ii.

Turn the power switch off and add coolant to the FULL line as the coolant level will drop as the air bleeds. [*2]

NOTICE:
·

Be sure to turn the power switch off before adding SLLC.

·

Do not work on the components in the engine compartment while the power switch is on (READY) as the engine will operate intermittently.




iii.

Repeat steps [*1] and [*2] until air bleeding from the cooling system is completed.

Standard:

Air bleeding from the inverter cooling system is completed when the noise made by the inverter water pump with motor assembly becomes smaller and the circulation of coolant in the inverter reserve tank assembly improves.


HINT:

Loud noises made by the inverter water pump with motor assembly and poor circulation of coolant in the inverter reserve tank assembly indicate that there is air in the cooling system.




d.
A371710

After the air is completely bled from the cooling system, add coolant to the FULL line of inverter reserve tank assembly and install the reserve tank cap.


Hide 51444A 5.INSTALL REAR ENGINE UNDER COVER LH

a.

Install the rear engine under cover LH with the 2 screws and 6 clips.