Home › Vehicle Interior › HEATING / AIR CONDITIONING › ROOM TEMPERATURE SENSOR
RM32K0E _58 Vehicle Interior _061609 HEATING / AIR CONDITIONING _0300407 ROOM TEMPERATURE SENSOR G

HEATING / AIR CONDITIONING  ROOM TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 88625Q 1.INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)

a.

Check the resistance.

i.
E268072C01
1.802,1.115 2.344,0.99 false 1.427,2.885 1.865,2.542 false 0.313,0.333 0.677,0.635 0.365,0.302 10 *a 2.375,0.896 2.74,1.198 0.365,0.302 10 *b 0.094,2.688 0.458,2.99 0.365,0.302 10 *c 1.875,4.281 2.24,4.583 0.365,0.302 10 *d 1.906,2.448 2.271,2.75 0.365,0.302 10 *e
*a Component without harness connected
(Cooler Thermistor (Room Temperature Sensor))
*b Sensing Portion
*c Resistance (kΩ)
*d Temperature (°C (°F))
*e Allowable Range


Measure the resistance according to thevalue(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
15°C (59°F) 2.45 to 2.88 kΩ
20°C (68°F) 1.95 to 2.30 kΩ
25°C (77°F) 1.60 to 1.80 kΩ
30°C (86°F) 1.28 to 1.47 kΩ
35°C (95°F) 1.00 to 1.22 kΩ
40°C (104°F) 0.80 to 1.00 kΩ
45°C (113°F) 0.65 to 0.85 kΩ
50°C (122°F) 0.50 to 0.70 kΩ
55°C (131°F) 0.44 to 0.60 kΩ
60°C (140°F) 0.36 to 0.50 kΩ


NOTICE:
·

Hold the cooler thermistor (room temperature sensor) only by its connector. Touching the sensing portion may change the resistancevalue.

·

When measuring, the cooler thermistor (room temperature sensor) temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).


If the result is not as specified, replace the cooler thermistor (room temperature sensor).