This DTC is stored if refrigerant pressure on the high pressure side is extremely low (0.195 MPaG (2.0 kgf/cm2, 28 psi) or less) or extremely high (2.812 MPaG (28.7 kgf/cm2, 408 psi) or more). The air conditioner pressure (2 words) sensor, which is installed to the high pressure side pipe to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning conditioner pressure (2 words) converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1423 | Pressure Sensor Circuit | Any of the following conditions is met:
·
Open in air conditioner pressure sensor circuit ·
Short in air conditioner pressure sensor circuit ·
Refrigerant pressure on high pressure side is extremely low (0.195 MPaG (2.0 kgf/cm2, 28 psi) or less) or extremely high (2.812 MPaG (28.7 kgf/cm2, 408 psi) or more) |
·
Air conditioner pressure sensor ·
Harness or connector ·
Air conditioning amplifier assembly ·
Cooler expansion valve (blocked, stuck) ·
Cooler condenser assembly (blocked, deterioration of cooling capacity due to dirt) ·
Cooler dryer (moisture in the refrigerant cycle cannot be absorbed) ·
Cooling fan system (cooler condenser assembly cannot be cooled down) ·
Air conditioning system (leaks, blocked) ·
Refrigerant volume (excessive, low) |
- |
| Vehicle Condition | |||||
|---|---|---|---|---|---|
| Pattern 1 | Pattern 2 | Pattern 3 | Pattern 4 | ||
| Diagnosis Condition | Power switch on (IG) | ○ | ○ | ○ | ○ |
| Malfunction Status | Open in air conditioner pressure sensor circuit | ○ | - | - | - |
| Short in air conditioner pressure sensor circuit | - | ○ | - | - | |
| Refrigerant pressure on high pressure side is extremely low (0.195 MPaG (2.0 kgf/cm2, 28 psi) or less) | - | - | ○ | - | |
| Refrigerant pressure on high pressure side is extremely high (2.812 MPaG (28.7 kgf/cm2, 408 psi) or more) | - | - | - | ○ | |
| Detection Time | 4 seconds or more | 4 seconds or more | 4 seconds or more | 4 seconds or more | |
| Number of Trips | 1 trip | 1 trip | 1 trip | 1 trip | |
Be sure to check the refrigerant volume first when this DTC is output because this DTC can also be stored if there is no refrigerant in the cycle.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFO-1234yf(R1234yf))>REPLACEMENT
If DTC B1423/23 and B14B8 are output at the same time, troubleshoot for DTC B14B8 first.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>B14B8
Make sure that the connector is properly connected. If it is not, securely connect it and check for DTCs again.
Check for DTCs.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>DTC CHECK / CLEAR
| Result | Proceed to |
|---|---|
| DTC B14B8 is not output | A |
| DTC B14B8 is output | B |
A
B
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -0.4566 MPaG
Max.: 3.2943 MPaG |
Actual refrigerant pressure displayed | - |
| Tester Display |
|---|
| Regulator Pressure Sensor |
Install a manifold gauge set.
Compare the values displayed in the Data List and on the manifold gauge set.
| Result | Proceed to |
|---|---|
| Data List value and manifold gauge set value do not match and Data List value: 0.195 MPaG (2.0 kgf/cm2, 28 psi) or less | A |
| Data List value and manifold gauge set value do not match and Data List value: 2.812 MPaG (28.7 kgf/cm2, 408 psi) or more | B |
| Data List value matches manifold gauge set value | C |
A
B
C
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -0.4566 MPaG
Max.: 3.2943 MPaG |
Actual refrigerant pressure displayed | - |
| Tester Display |
|---|
| Regulator Pressure Sensor |
Disconnecting the A22 connector of the air conditioner pressure sensor causes the Data List value to change.
| Result | Proceed to |
|---|---|
| Regulator pressure sensor value changes | A |
| Regulator pressure sensor value does not change | B |
A
B
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A22-3 (+) - Body ground | Power switch on (IG) | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F71 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-3 (+) - F71-6 (S5-3) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A22-2 (PR) - Body ground | Power switch on (IG) | 3.0 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F71 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-2 (PR) or F71-24 (PRE) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A22 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-1 (-) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A22-2 (PR) - Body ground | Power switch on (IG) | 3.0 to 5.25 V |
| Result | Proceed to |
|---|---|
| 5.25 V or higher | A |
| 3.0 to 5.25 V | B |
| Below 3.0 V | C |
A
B
C
Disconnect the F71 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-2 (PR) or F71-24 (PRE) - Other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A22-3 (+) - A22-2 (PR) | Power switch off | 180 to 220 kΩ |
After turning the power switch off, wait at least 30 seconds before performing the measurement.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F71 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-2 (PR) or F71-24 (PRE) - A22-3 (+) or F71-6 (S5-3) | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F71 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-2 (PR) - F71-24 (PRE) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F71 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-1 (-) - F71-2 (SG-2) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG