89730A
1.INSPECT SECURITY WARNING RELAY
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Connection |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage applied to terminal 1 and 2 | Below 1 Ω |
| 3 - 5 | Auxiliary battery voltage not applied to terminal 1 and 2 | 10 kΩ or higher |