Do not apply positive (+) auxiliary battery voltage to any terminals, except terminal 2 (B), to avoid damaging the pulse sensor inside the motor.
Perform initialization of the power window system after removing, inspecting or replacing the power window regulator motor assembly.
Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM>INITIALIZATION
1.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH
| *a | Component without harness connected
(Power Window Regulator Motor Assembly LH) |
| *b | Clockwise |
| *c | Counterclockwise |
| *d | Motor Gear |
Connect a positive (+) auxiliary battery lead to connector terminal 2 (B).
Do not connect a positive (+) auxiliary battery lead to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
Connect a negative (-) auxiliary battery lead to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).
Check that the motor gear rotates smoothly as follows:
| Measurement Condition | Specified Condition |
|---|---|
1.
Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more. 2.
With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 10 (UP). |
Motor gear rotates clockwise |
1.
Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more. 2.
With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 7 (DOWN). |
Motor gear rotates counterclockwise |
If the result is not as specified, replace the power window regulator motor assembly LH.
2.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
| *a | Component without harness connected
(Power Window Regulator Motor Assembly RH) |
| *b | Clockwise |
| *c | Counterclockwise |
| *d | Motor Gear |
Connect a positive (+) auxiliary battery lead to connector terminal 2 (B).
Do not connect a positive (+) auxiliary battery lead to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
Connect a negative (-) auxiliary battery lead to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).
Check that the motor gear rotates smoothly as follows:
| Measurement Condition | Specified Condition |
|---|---|
1.
Connect the positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more. 2.
With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 10 (UP). |
Motor gear rotates counterclockwise |
1.
Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more. 2.
With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 7 (DOWN). |
Motor gear rotates clockwise |
If the result is not as specified, replace the power window regulator motor assembly RH.