The main body ECU (multiplex network body ECU) controls the ambient illumination lights.
Inspect the lights for circuits related to this system before performing the following procedure.
Before replacing the main ECU (multiplex network body ECU), refer to Service Bulletin.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Interior Illumination Light1 | ·
Cup holder illumination light ·
Door ambient illumination light |
ON or OFF | Preconditions for using the Active Test to check dimmer controlled illumination:
·
Power switch on (IG). ·
Shift lever is in any position other than P. |
| Interior Illumination Light2 | ·
Cup holder illumination light ·
Door ambient illumination light |
ON or OFF | Preconditions for using the Active Test to check dimmer controlled illumination:
·
Power switch on (IG). ·
Shift lever is in any position other than P. |
| Tester Display |
|---|
| Interior Illumination Light1 |
| Tester Display |
|---|
| Interior Illumination Light2 |
Ambient illumination lights comes on.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (All ambient lights do not illuminate) | B |
| NG (Cup holder illumination light does not illuminate) | C |
| NG (Door ambient illumination light does not illuminate) | D |
A
B
C
D
Disconnect the 3K instrument panel junction block assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3K-1 - Body ground | Power switch off | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the 3D instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3K-1 - 3D-24 | Always | Below 1 Ω |
| 3K-1 - 3D-25 | Always | Below 1 Ω |
| 3K-1 - 3D-26 | Always | Below 1 Ω |
| 3K-1 - 3D-27 | Always | Below 1 Ω |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for LHD) | B |
| NG (for RHD) | C |
A
B
C
Disconnect the 3D instrument panel junction block assembly connector.
Disconnect the 3K instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3K-1 - 3D-26 | Always | Below 1 Ω |
| 3K-1 - 3D-27 | Always | Below 1 Ω |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for LHD) | B |
| NG (for RHD) | C |
A
B
C
Disconnect the F87 instrument cluster finish panel garnish connector.
Disconnect the F88 instrument cluster finish panel center garnish connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F87-2 (B) - 3D-26 | Always | Below 1 Ω |
| F88-2 (B) - 3D-27 | Always | Below 1 Ω |
| F87-2 (B) or 3D-26 - Body ground | Always | 10 kΩ or higher |
| F88-2 (B) or 3D-27 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F16 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F87-1 (E) - F16-21(LED1) | Always | Below 1 Ω |
| F88-1 (E) - F16-21 (LED1) | Always | Below 1 Ω |
| F87-1 (E) or F16-21(LED1) - Body ground | Always | 10 kΩ or higher |
| F88-1 (E) or F16-21 (LED1) - Body ground | Always | 10 kΩ or higher |
| Result | Proceed to |
|---|---|
| OK (for LHD) | A |
| OK (for RHD) | B |
| NG | C |
A
B
C
Disconnect the instrument panel junction block assembly connectors.
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3K-1 - 3D-24 | Always | Below 1 Ω |
| 3K-1 - 3D-25 | Always | Below 1 Ω |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for LHD) | B |
| NG (for RHD) | C |
A
B
C
Disconnect the I11 No. 1 interior illumination light assembly RH connector.
Disconnect the J9 No. 1 interior illumination light assembly LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I11-1 (+) - 3D-24 | Always | Below 1 Ω |
| I11-1 (+) or 3D-24 - Body ground | Always | 10 kΩ or higher |
| J9-1 (+) - 3D-25 | Always | Below 1 Ω |
| J9-1 (+) or 3D-25 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F16 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I11-2 (-) - F16-22 (LED2) | Always | Below 1 Ω |
| I11-2 (-) or F16-22 (LED2) - Body ground | Always | 10 kΩ or higher |
| J9-2 (-) - F16-22 (LED2) | Always | Below 1 Ω |
| J9-2 (-) or F16-22 (LED2) - Body ground | Always | 10 kΩ or higher |
| Result | Proceed to |
|---|---|
| OK (for LHD) | A |
| OK (for RHD) | B |
| NG | C |
A
B
C