Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2018.05–2019.09
RM32K0E _51 Engine / Hybrid System _059620 HYBRID / BATTERY CONTROL _0292486 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0A1B94  Drive Motor "A" Control Module Unexpected Operation  


DTC SUMMARY

MALFUNCTION DESCRIPTION


The hybrid vehicle control ECU monitors the motor generator control ECU (MG ECU).

The cause of this malfunction may be the following:

Motor generator control ECU internal malfunction
·

Motor generator control ECU (MG ECU) malfunction



DESCRIPTION

The hybrid vehicle control ECU monitors the motor generator control ECU (MG ECU) and stores this DTC when it detects a malfunction.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A1B94 Drive Motor "A" Control Module Unexpected Operation The motor generator control ECU (MG ECU) value received by the hybrid vehicle control ECU exceeds the threshold for a certain period of time.
(1 trip detection logic)
·

Inverter with Converter Assembly

·

Fusible link block assembly (BATT-MAIN)

·

IGCT-IG fuse

·

IGCT relay


Comes on Master Warning:
Comes on

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

With power switch on (IG) and wait for 2 minutes or more.

HINT:

If the vehicle has returned to normal, it can be driven after turning the power switch on (READY).


7.

Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




WIRING DIAGRAM

A394807E01
0.854,3.094 3.458,3.292 2.604,0.198 10 false Auxiliary Battery 0.531,2.333 0.688,2.531 0.156,0.198 10 false A 0.458,1.573 0.781,1.74 0.323,0.167 10 false A71 0.885,0.938 1.958,1.135 1.073,0.198 10 false IGCT-IG 0.896,0.698 1.052,0.896 0.156,0.198 10 false 1 1.292,0.688 1.448,0.885 0.156,0.198 10 false 2 1.885,1.104 2.042,1.302 0.156,0.198 10 false 2 1.885,0.688 2.042,0.885 0.156,0.198 10 false 3 2.688,1.104 2.844,1.302 0.156,0.198 10 false 1 2.688,0.688 2.844,0.885 0.156,0.198 10 false 5 2.177,1.531 3.25,1.729 1.073,0.198 10 false IGCT 0.865,1.854 2.698,2.313 1.833,0.458 10 false Fusible Link Block Assembly (BATT-MAIN) 0.313,1.573 0.469,1.771 0.156,0.198 10 false 1 0.302,2.333 0.458,2.531 0.156,0.198 10 false 1 4.115,0.927 5.188,1.125 1.073,0.198 10 false PM-IGCT 4.083,3.365 5.156,3.563 1.073,0.198 10 false IGCT NO. 2 4.188,3.115 4.344,3.313 0.156,0.198 10 false 1 4.135,0.698 4.292,0.896 0.156,0.198 10 false 1 4.573,0.688 4.729,0.885 0.156,0.198 10 false 2 4.635,3.115 4.792,3.313 0.156,0.198 10 false 2 5.313,0.365 5.729,0.563 0.417,0.198 10 false A48 5.313,0.781 5.677,0.979 0.365,0.198 10 false A49 5.313,1.208 5.708,1.427 0.396,0.219 10 false A48 5.365,1.667 5.792,1.865 0.427,0.198 10 false F2 5.396,0.177 5.813,0.375 0.417,0.198 10 false 4 5.396,0.604 5.813,0.802 0.417,0.198 10 false 1 5.396,1.021 5.813,1.219 0.417,0.198 10 false 6 5.396,1.479 5.823,1.677 0.427,0.198 10 false 6 5.677,1.208 6.146,1.417 0.469,0.208 10 false MREL 5.677,0.781 6.24,0.99 0.563,0.208 10 false +B2 5.677,0.365 6.333,0.573 0.656,0.208 10 false +B1 5.677,1.667 6.135,1.896 0.458,0.229 10 false E1 5.344,3.115 5.823,3.281 0.479,0.167 10 false 12 5.563,2.219 6.5,2.604 0.938,0.385 10 false Hybrid Vehicle Control ECU 5.344,3.458 5.823,3.625 0.479,0.167 10 false 24 5.677,3.219 6.25,3.458 0.573,0.24 10 false IGCT 5.677,3.552 6.323,3.781 0.646,0.229 10 false GND1 5.302,4.052 6.698,4.479 1.396,0.427 10 false Inverter with Converter Assembly 5.302,3.896 5.948,4.125 0.646,0.229 10 false C65

PROCEDURE

1.CHECK AUXILIARY BATTERY TERMINAL (CONTACT PROBLEM)
a.

Check the connection of the negative (-) and positive (+) auxiliary battery terminals.

OK:

The terminals are connected securely and there is no contact problem.


HINT:

If performing a reproduction test, turn the power switch on (IG) and shake the wire harnesses vertically and horizontally before checking for DTCs.



Result:
Proceed to
OK
NG



OK

2.CHECK GROUND WIRE CONNECTION CONDITION

NG

7.CONNECT SECURELY
2.CHECK GROUND WIRE CONNECTION CONDITION
a.

Check the installation condition of the ground wires DA and DC.

A394816N01
2.479,1.688 2.729,1.854 0.25,0.167 10 true DC 5.708,0.917 5.958,1.083 0.25,0.167 10 true DA

OK:

The ground wires DA and DC are securely installed.


HINT:

If performing a reproduction test, turn the power switch on (IG) and shake the wire harnesses vertically and horizontally before checking for DTCs.



Result:
Proceed to
OK
NG



OK

3.CHECK FUSIBLE LINK (BATT-MAIN)

NG

8.CONNECT SECURELY
3.CHECK FUSIBLE LINK (BATT-MAIN)
a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the cable from the positive (+) auxiliary battery terminal.


c.

Check the fusible link block assembly (BATT-MAIN) for improper installation.

OK:

The fusible link block assembly is installed securely and there is no contact problem.



d.
A384973C05
2.177,0.771 2.563,0.99 0.385,0.219 0.927,0.458 1.292,0.646 0.365,0.188 0.073,0.052 0.385,0.208 0.313,0.156 10 false *1 2.219,0.802 2.552,0.958 0.333,0.156 10 true A71 1.063,0.458 1.302,0.656 0.24,0.198 10 false A
*1 Fusible Link Block Assembly


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A71-1 - A-1 (Positive (+) auxiliary battery terminal) Power switch off Below 1 Ω



e.

Reconnect the cable from the positive (+) auxiliary battery terminal.


f.

Reconnect the cable from the negative (-) auxiliary battery terminal.


Result:
Proceed to
OK
NG



OK

4.CHECK FUSE (IGCT-IG)

NG

9.REPAIR OR REPLACE MALFUNCTIONING PARTS
4.CHECK FUSE (IGCT-IG)
a.

Check the IGCT-IG fuse for improper installation.

OK:

The fuse is installed securely.


HINT:

If performing a reproduction test, turn the power switch on (IG) and gently vibrate the IGCT-IG fuse with a finger before checking for DTCs.



b.
A389508C01
2.688,1.979 1.958,1.333 true 0.354,0.167 0.667,0.323 0.313,0.156 10 false *1 2.74,2.01 3.052,2.167 0.313,0.156 10 false *2
*1 No. 1 Engine Room Relay Block
*2 IGCT-IG Fuse


Remove the IGCT-IG fuse from the No. 1 engine room relay block.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
IGCT-IG fuse Power switch off Below 1 Ω



d.

Install the IGCT-IG fuse to the No. 1 engine room relay block.


Result:
Proceed to
OK
NG



OK

5.CHECK RELAY (IGCT)

NG

10.REPAIR OR REPLACE MALFUNCTIONING PARTS
5.CHECK RELAY (IGCT)
a.

Check the IGCT relay for improper installation.

OK:

The relay is installed securely.


HINT:

If performing a reproduction test, turn the power switch on (IG) and gently vibrate the IGCT relay with a finger before checking for DTCs.



b.
A389507C01
2.583,2.667 1.625,2.052 true 0.354,0.167 0.667,0.323 0.313,0.156 10 false *1 2.625,2.635 2.938,2.792 0.313,0.156 10 false *2
*1 No. 1 Engine Room Relay Block
*2 IGCT Relay


Remove the IGCT relay from the No. 1 engine room relay block.


c.
A253297C19
0.146,0.056 0.409,0.261 0.263,0.205 10 *1
*1 IGCT Relay


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω



d.

Install the IGCT relay.


Result:
Proceed to
OK
NG



OK

6.CHECK DTC OUTPUT (HYBRID CONTROL)

NG

11.REPAIR OR REPLACE MALFUNCTIONING PARTS
6.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check for DTCs.

HINT:

Check the DTCs that were output when the vehicle was brought to the workshop.


Powertrain > Hybrid Control > Trouble Codes
50001 397
Result:
Result Proceed to
P0A1B94 only is output. A
DTCs except P0A1B94 are output. B



e.

Turn the power switch off.



A

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

B

7.CONNECT SECURELY
Result:
Proceed to
NEXT



NEXT

12.CLEAR DTC
8.CONNECT SECURELY
Result:
Proceed to
NEXT



NEXT

12.CLEAR DTC
9.REPAIR OR REPLACE MALFUNCTIONING PARTS
Result:
Proceed to
NEXT



NEXT

12.CLEAR DTC
10.REPAIR OR REPLACE MALFUNCTIONING PARTS
Result:
Proceed to
NEXT



NEXT

12.CLEAR DTC
11.REPAIR OR REPLACE MALFUNCTIONING PARTS
Result:
Proceed to
NEXT



NEXT

12.CLEAR DTC
12.CLEAR DTC

NEXT

13.SIMULATION TEST
13.SIMULATION TEST
a.

Turn the power switch off and wait for 2 minutes or more.


b.

Turn the power switch on (IG) and wait for 2 minutes or more.


c.

Turn the power switch off.


Result:
Proceed to
NEXT



NEXT

14.CHECK DTC OUTPUT (HYBRID CONTROL)
14.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Result:
Result Proceed to
No DTCs are output. A
P0A1B94 only is output. B
DTCs except P0A1B94 are output. C



e.

Turn the power switch off.



A

END

B

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

C