The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors its internal operation and will store DTCs if it detects a malfunction. If any of the following DTCs are output, replace the inverter with converter assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning
Comes on |
| P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning
Comes on |
| P0A1A47 | Generator Control Module Watchdog / Safety μC Failure | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning
Comes on |
| P0A1A49 | Generator Control Module Internal Electronic Failure | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning
Comes on |
| P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning
Comes on |
| P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning
Comes on |
| P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning
Comes on |
| P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning
Comes on |
| P1C601F | Generator Control Module Position Sensor REF Power Source Circuit Intermittent | Motor generator control ECU internal malfunction detected when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic) |
Inverter with converter assembly | Does not come on | Master Warning
Does not come on |
| P1C621F | Generator Control Module Offset Power Circuit Intermittent | Motor generator control ECU internal malfunction detected when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic) |
Inverter with converter assembly | Does not come on | Master Warning
Does not come on |
| P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning
Comes on |
| P313386 | Communication Error from Generator to Drive Motor "A" Signal Invalid | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning
Comes on |
| P313387 | Communication Error from Generator to Drive Motor "A" Missing Message | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning
Comes on |
| P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning
Comes on |
| P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning
Comes on |
| P313487 | Communication Error from Drive Motor "A" to Generator Missing Message | Motor generator control ECU internal malfunction
(1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning
Comes on |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
With power switch on (IG) and wait for 15 seconds or more.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>DTC CHECK / CLEAR
| Proceed to |
|---|
| NEXT |
NEXT