This DTC is stored if refrigerant pressure on the high pressure side is extremely low (0.176 MPaG (1.8 kgf/cm2, 26 psi) or less) or extremely high (3.025 MPaG (30.8 kgf/cm2, 439 psi) or more). The air conditioner pressure sensor, which is installed to the high pressure side pipe to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor.
This DTC is stored if refrigerant pressure on the high pressure side is extremely low (0.196 MPaG (2.0 kgf/cm2, 28 psi) or less) or extremely high (2.812 MPaG (28.7 kgf/cm2, 408 psi) or more). The air conditioner pressure sensor, which is installed to the high pressure side pipe to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning conditioner pressure converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1423 | Pressure Sensor Circuit | Any of the following conditions is met:
·
Open in air conditioner pressure sensor circuit ·
Short in air conditioner pressure sensor circuit ·
Refrigerant pressure on high pressure side is extremely low (0.176 MPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3.025 MPa (30.8 kgf cm2, 439 psi) or more)*1 ·
Refrigerant pressure on high pressure side is extremely low (0.195 MPaG (2.0 kgf/cm2, 28 psi) or less) or extremely high (2.812 MPaG (28.7 kgf/cm2, 408 psi) or more)*2 |
·
Air conditioner pressure sensor ·
Harness or connector ·
Air conditioning amplifier assembly ·
Cooler expansion valve (blocked, stuck) ·
Cooler condenser assembly (blocked, deterioration of cooling capacity due to dirt) ·
Cooler dryer (moisture in the refrigerant cycle cannot be absorbed) ·
Cooling fan system (cooler condenser assembly cannot be cooled down) ·
Air conditioning system (leaks, blocked) ·
Refrigerant volume (excessive, low) |
- |
| Vehicle Condition | ||||
|---|---|---|---|---|
| Pattern 1 | Pattern 2 | Pattern 3 | ||
| Diagnosis Condition | Power switch on (IG) | ○ | ○ | ○ |
| Malfunction Status | Open in air conditioner pressure sensor circuit | ○ | - | - |
| Short in air conditioner pressure sensor circuit | - | ○ | - | |
| Refrigerant pressure on high pressure side is extremely low (0.176 MPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3.025 MPa (30.8 kgf cm2, 439 psi) or more)*1 | - | - | ○ | |
| Refrigerant pressure on high pressure side is extremely low (0.195 MPaG (2.0 kgf/cm2, 28 psi) or less) or extremely high (2.812 MPaG (28.7 kgf/cm2, 408 psi) or more)*2 | - | - | - | |
| Detection Time | 4 seconds or more | 4 seconds or more | 4 seconds or more | |
| Number of Trips | 1 trip | 1 trip | 1 trip | |
*1: for HFC-134a(R134a)
*2: for HFO-1234yf(R1234yf)
Be sure to check the refrigerant volume first when this DTC is output because this DTC can also be stored if there is no refrigerant in the cycle.
for HFO-1234yf(R1234yf):
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFO-1234yf(R1234yf))>REPLACEMENT
for HFC-134a(R134a):
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT (for HFC-134a(R134a))>REPLACEMENT
If DTC B1423 and B14B8 are output at the same time, troubleshoot for DTC B14B8 first.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>B14B8
Make sure that the connector is properly connected. If it is not, securely connect it and check for DTCs again.
Check for DTCs.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>DTC CHECK / CLEAR
| Result | Proceed to |
|---|---|
| DTC B14B8 is not output (for HFC-134a(R134a)) | A |
| DTC B14B8 is not output (for HFO-1234yf(R1234yf)) | B |
| DTC B14B8 is output | C |
A
B
C
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -0.45668 MPaG
Max.: 3.29437 MPaG |
Actual refrigerant pressure displayed | - |
| Tester Display |
|---|
| Regulator Pressure Sensor |
Install a manifold gauge set.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT (for HFC-134a(R134a))>ON-VEHICLE INSPECTION
Compare the values displayed in the Data List and on the manifold gauge set.
| Result | Proceed to |
|---|---|
| Data List value and manifold gauge set value do not match and Data List value: 0.176 MPaG (1.8 kgf/cm2, 26 psi) or less | A |
| Data List value and manifold gauge set value do not match and Data List value: 3.025 MPaG (30.8 kgf/cm2, 439 psi) or more | B |
| Data List value matches manifold gauge set value | C |
A
B
C
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT (for HFC-134a(R134a))>ON-VEHICLE INSPECTION
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -0.45668 MPaG
Max.: 3.29437 MPaG |
Actual refrigerant pressure displayed | - |
| Tester Display |
|---|
| Regulator Pressure Sensor |
Install a manifold gauge set.
Compare the values displayed in the Data List and on the manifold gauge set.
| Result | Proceed to |
|---|---|
| Data List value and manifold gauge set value do not match and Data List value: 0.195 MPaG (2.0 kgf/cm2, 28 psi) or less | A |
| Data List value and manifold gauge set value do not match and Data List value: 2.812 MPaG (28.7 kgf/cm2, 408 psi) or more | B |
| Data List value matches manifold gauge set value | C |
A
B
C
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -0.45668 MPaG
Max.: 3.29437 MPaG |
Actual refrigerant pressure displayed | - |
| Tester Display |
|---|
| Regulator Pressure Sensor |
Disconnecting the A22 connector of the air conditioner pressure sensor causes the Data List value to change.
| Result | Proceed to |
|---|---|
| Regulator pressure sensor value changes | A |
| Regulator pressure sensor value does not change | B |
A
B
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A22-3 (+) - Body ground | Power switch on (IG) | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F71 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-3 (+) - F71-6 (S5-3) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A22-2 (PR) - Body ground | Power switch on (IG) | 3.0 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F71 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-2 (PR) or F71-24 (PRE) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A22 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-1 (-) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A22-2 (PR) - Body ground | Power switch on (IG) | 3.0 to 5.25 V |
| Result | Proceed to |
|---|---|
| 5.25 V or higher | A |
| 3.0 to 5.25 V | B |
| Below 3.0 V | C |
A
B
C
Disconnect the F71 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-2 (PR) or F71-24 (PRE) - Other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A22-3 (+) - A22-2 (PR) | Power switch off | 180 to 220 kΩ |
After turning the power switch off, wait at least 30 seconds before performing the measurement.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F71 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-2 (PR) or F71-24 (PRE) - A22-3 (+) or F71-6 (S5-3) | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F71 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-2 (PR) - F71-24 (PRE) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F71 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-1 (-) - F71-2 (SG-2) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG