1.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY
Inspect SMRB:
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(HV Battery Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| T3-1 (CBI) - A-1 (+) | Auxiliary battery voltage not applied between terminals M42-1 (SMRB) and M42-3 (GND) | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals M42-1 (SMRB) and M42-3 (GND) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M42-1 (SMRB) - M42-3 (GND) | -40 to 80°C (-40 to 176°F) | 20.6 to 40.8 Ω |
If the result is not as specified, replace the HV battery junction block assembly.
Inspect SMRG:
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(HV Battery Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| T2-1 (CEI) - z10-1 (-) | Auxiliary battery voltage not applied between terminals M42-4 (SMRG) and M42-3 (GND) | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals M42-4 (SMRG) and M42-3 (GND) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M42-4 (SMRG) - M42-3 (GND) | -40 to 80°C (-40 to 176°F) | 20.6 to 40.8 Ω |
If the result is not as specified, replace the HV battery junction block assembly.
Inspect SMRP:
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(HV Battery Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| T2-1 (CEI) - z10-1 (-) | Auxiliary battery voltage applied between terminals M42-2 (SMRP) and M42-3 (GND) | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals M42-2 (SMRP) and M42-3 (GND) | 24.3 and 29.7 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M42-2 (SMRP) - M42-3 (GND) | -40 to 80°C (-40 to 176°F) | 140 to 290 Ω |
If the result is not as specified, replace the HV battery junction block assembly.