Home › Engine / Hybrid System › 2ZR-FXE (HYBRID / BATTERY CONTROL) › HV RELAY ASSEMBLY (for LITHIUM-ION BATTERY) › from 2019.09
RM32K0E _51 Engine / Hybrid System _083958 2ZR-FXE HYBRID / BATTERY CONTROL _0404393 HV RELAY ASSEMBLY(for LITHIUM-ION BATTERY) G

2ZR-FXE HYBRID / BATTERY CONTROL  HV RELAY ASSEMBLY(for LITHIUM-ION BATTERY)  INSPECTION  


PROCEDURE

Hide G92Z0 1.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY

a.

Inspect SMRB:

i.

Measure the resistance according to the value(s) in the table below.

A439747C35
3.76,1.031 4.115,1.24 0.354,0.208 3.229,0.125 3.594,0.375 0.365,0.25 5.615,0.188 6.01,0.406 0.396,0.219 3.115,1.354 3.385,1.188 true 3.771,1.354 3.604,1.177 true 3.417,0.667 3.729,0.385 true 6.292,1.083 5.792,0.688 true 0.573,0.146 0.885,0.302 0.313,0.156 10 false *a 3.802,1.052 4.26,1.25 0.458,0.198 10 false M42 2.958,1.385 3.292,1.594 0.333,0.208 10 true GND 3.667,1.385 4.125,1.583 0.458,0.198 10 true SMRB 5.688,0.219 5.948,0.385 0.26,0.167 10 true z24 3.781,0.313 4.24,0.51 0.458,0.198 10 false CBI 3.292,0.156 3.552,0.333 0.26,0.177 10 true T3 6.375,1.031 6.531,1.229 0.156,0.198 10 false +
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
z24-1 (+) - T3-1 (CBI) Auxiliary battery voltage not applied between terminals M42-1 (SMRB) and M42-3 (GND) 10 kΩ or higher
Auxiliary battery voltage applied between terminals M42-1 (SMRB) and M42-3 (GND) Below 1 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M42-1 (SMRB) - M42-3 (GND) -40 to 80°C (-40 to 176°F) 20.6 to 40.8 Ω


If the result is not as specified, replace the HV battery junction block assembly.



b.

Inspect SMRG:

i.

Measure the resistance according to the value(s) in the table below.

A439747C36
3.76,1.031 4.115,1.24 0.354,0.208 2.219,0.104 2.583,0.344 0.365,0.24 1.167,0.115 1.531,0.323 0.365,0.208 3.115,1.354 3.281,1.188 true 3.667,1.344 3.417,1.177 true 2.063,1.063 2.396,0.677 true 0.833,0.854 1.344,0.656 true 0.573,0.146 0.885,0.302 0.313,0.156 10 false *a 3.813,1.063 4.271,1.26 0.458,0.198 10 false M42 3.594,1.385 3.979,1.646 0.385,0.26 10 true GND 2.865,1.396 3.354,1.625 0.49,0.229 10 true SMRG 2.313,0.146 2.573,0.323 0.26,0.177 10 true T2 1.229,0.135 1.51,0.313 0.281,0.177 10 true z19 1.813,1 2.188,1.208 0.375,0.208 10 false CEI 0.719,0.781 0.875,0.979 0.156,0.198 10 false -
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
z19-1 (-) - T2-1 (CEI) Auxiliary battery voltage not applied between terminals M42-4 (SMRG) and M42-3 (GND) 10 kΩ or higher
Auxiliary battery voltage applied between terminals M42-4 (SMRG) and M42-3 (GND) Below 1 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M42-4 (SMRG) - M42-3 (GND) -40 to 80°C (-40 to 176°F) 20.6 to 40.8 Ω


If the result is not as specified, replace the HV battery junction block assembly.



c.

Inspect SMRP:

i.

Measure the resistance according to the value(s) in the table below.

A439747C37
3.76,1.031 4.115,1.24 0.354,0.208 2.219,0.104 2.583,0.344 0.365,0.24 1.167,0.115 1.531,0.323 0.365,0.208 3.115,1.354 3.385,1.188 true 3.76,1.344 3.51,1.177 true 2.063,1.063 2.396,0.677 true 0.833,0.854 1.344,0.656 true 0.573,0.146 0.885,0.302 0.313,0.156 10 false *a 3.823,1.063 4.281,1.26 0.458,0.198 10 false M42 2.958,1.385 3.292,1.594 0.333,0.208 10 true GND 3.667,1.385 4.125,1.594 0.458,0.208 10 true SMRP 1.24,0.135 1.521,0.302 0.281,0.167 10 true z19 2.281,0.135 2.552,0.302 0.271,0.167 10 true T2 1.813,1 2.188,1.208 0.375,0.208 10 false CEI 0.719,0.781 0.875,0.979 0.156,0.198 10 false -
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
z19-1 (-) - T2-1 (CEI) Auxiliary battery voltage not applied between terminals M42-2 (SMRP) and M42-3 (GND) 10 kΩ or higher
Auxiliary battery voltage applied between terminals M42-2 (SMRP) and M42-3 (GND) 24.3 to 29.7 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M42-2 (SMRP) - M42-3 (GND) -40 to 80°C (-40 to 176°F) 140 to 290 Ω


If the result is not as specified, replace the HV battery junction block assembly.