Home › Engine / Hybrid System › M20A-FXS (ENGINE CONTROL) › SFI SYSTEM › from 2019.09
RM32K0E _51 Engine / Hybrid System _083960 M20A-FXS ENGINE CONTROL _0404405 SFI SYSTEM C

M20A-FXS ENGINE CONTROL  SFI SYSTEM  P010012  Mass or Volume Air Flow Sensor "A" Circuit Short to Battery  P010014  Mass or Volume Air Flow Sensor "A" Circuit Short to Ground or Open  


DESCRIPTION

The mass air flow meter is a sensor that measures the intake air volume using the following built-in components:

·

By-pass duct (allows some of the intake air to flow past a silicon chip sensor)

·

Silicon chip sensor (uses a heater control bridge circuit and temperature sensor bridge circuit to detect the difference in the temperature of the intake air that passes the sensors positioned before and after the heater).

·

Control circuit (converts the difference in temperature into a pulse signal and performs correction)


Intake air flows past the temperature sensor (before heater), the heater, and then the temperature sensor (after heater) of the silicon chip sensor in the by-pass duct. As the intake air is warmed up when it is exposed to the heater, the temperature of the intake air as it flows past the temperature sensor (after heater) is higher than when it flows past the temperature sensor (before heater). The difference in temperature of the intake air at each temperature sensor varies depending on the velocity of the intake air that flows past the silicon chip sensor. The temperature sensor bridge circuit detects the difference in temperature and the control circuit converts it into a pulse signal and outputs it to the ECM. When the temperature detected by the temperature sensor (before heater) is higher than that detected by the temperature sensor (after heater), backflow of the intake air is detected.

The ECM calculates the intake air volume based on the pulse signal received from the mass air flow meter, and uses it to determine the fuel injection duration necessary for an optimal air-fuel ratio.

The heater control bridge circuit has a temperature sensor and power transistor, and maintains the temperature differential between the heater temperature and intake air temperature at a specific level.

HINT:

When DTCs are stored, the ECM enters fail-safe mode. During fail-safe mode, the ECM calculates the fuel injection duration based on the engine speed and throttle valve angle. Fail-safe mode continues until a pass condition is detected.


A431660C01
5.073,1.719 4.917,0.917 4.917,0.917 4.75,0.917 true 5.073,2.521 5,3 5,3 4.833,3 true 0.667,3 0.833,3.5 0.833,3.5 1,3.5 true 6.5,2.333 6.333,2.333 6.333,2.333 6.26,2.063 true 0.417,0.333 0.667,0.5 0.25,0.167 10 false *1 6.427,1.49 6.677,1.646 0.25,0.156 10 false *a 3.125,1.49 3.375,1.656 0.25,0.167 10 false *b 4.635,2.917 4.885,3.073 0.25,0.156 10 false *c 4.531,0.844 4.781,1.01 0.25,0.167 10 false *d 3.646,1.854 3.958,2.01 0.313,0.156 10 false *e 1.063,3.427 1.375,3.583 0.313,0.156 10 false *f 6.583,2.25 6.833,2.406 0.25,0.156 10 false *f
*1 Mass Air Flow Meter - -
*a Upstream Side *b Downstream Side
*c Heater *d Temperature Distribution Without Airflow
*e Flow Rate Detection by Temperature Differential *f Intake Air


DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P010012 Mass or Volume Air Flow Sensor "A" Circuit Short to Battery The mass air flow meter output frequency is higher than 9.8 kHz for 3 seconds or more (1 trip detection logic).
·

Open or short in mass air flow meter circuit

·

Mass air flow meter sub-assembly

·

ECM


Comes on DTC stored SAE Code: P0103
P010014 Mass or Volume Air Flow Sensor "A" Circuit Short to Ground or Open The mass air flow meter output frequency is less than 0.1 kHz for 3 seconds or more (1 trip detection logic).
·

Open or short in mass air flow meter circuit

·

Mass air flow meter sub-assembly

·

ECM


Comes on DTC stored SAE Code: P0102

MONITOR DESCRIPTION

If there is a defect or an open or short circuit in the mass air flow meter, the frequency level deviates from the normal operating range. The ECM interprets this deviation as a malfunction in the mass air flow meter circuit and stores a DTC.

Example:

When the sensor output frequency remains less than 0.1 kHz, or higher than 9.8 kHz for 3 seconds, the ECM stores a DTC.

MONITOR STRATEGY

Frequency of Operation Continuous

CONFIRMATION DRIVING PATTERN

1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG).

3.

Turn the GTS on.

4.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

5.

Turn the power switch off and wait for at least 30 seconds.

6.

Turn the power switch on (IG).

7.

Turn the GTS on.

8.

Wait 5 seconds or more [A].

9.

Enter the following menus: Powertrain / Engine / Trouble Codes [B].

10.

Read the pending DTCs.

HINT:
·

If a pending DTC is output, the system is malfunctioning.

·

If a pending DTC is not output, perform the following procedure.



11.

Enter the following menus: Powertrain / Engine / Utility / All Readiness.

12.

Input the DTC: P010012 or P010014.

13.

Check the DTC judgment result.

GTS Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

Perform driving pattern after confirming DTC enabling conditions



HINT:
·

If the judgment result is NORMAL, the system is normal.

·

If the judgment result is ABNORMAL, the system has a malfunction.

·

If the judgment result is INCOMPLETE, perform steps [A] through [B] again.




WIRING DIAGRAM

A402064E46
1.313,1.031 1.646,1.219 0.333,0.188 10 false VCC 1.698,0.927 1.917,1.229 0.219,0.302 10 false 4 1.406,1.719 1.771,1.979 0.365,0.26 10 false FG 1.708,1.604 1.917,1.833 0.208,0.229 10 false 3 1.333,2.49 1.646,2.688 0.313,0.198 10 false E2G 1.729,2.375 1.885,2.573 0.156,0.198 10 false 2 0.396,2.896 0.719,3.125 0.323,0.229 10 false C84 0.396,3.073 2.781,3.438 2.385,0.365 10 false Mass Air Flow Meter 5.26,3.125 5.698,3.385 0.438,0.26 10 false C97 5.25,3.292 5.688,3.542 0.438,0.25 10 false ECM 4.354,0.917 4.677,1.198 0.323,0.281 10 false 78 4.625,0.917 5.188,1.208 0.563,0.292 10 false VCVG 5.615,0.698 6.073,0.896 0.458,0.198 10 false 5 V 4.281,1.604 4.594,1.802 0.313,0.198 10 false 101 4.625,1.604 4.969,1.865 0.344,0.26 10 false VG 4.365,2.385 4.667,2.635 0.302,0.25 10 false 79 4.604,2.396 5.063,2.594 0.458,0.198 10 false E2G 5.271,1.417 5.927,1.75 0.656,0.333 10 false 2.2 kΩ

CAUTION / NOTICE / HINT

NOTICE:
·

Vehicle Control History may be stored in the hybrid vehicle control ECU assembly if the engine is malfunctioning. Certain vehicle condition information is recorded when Vehicle Control History is stored. Reading the vehicle conditions recorded in both the freeze frame data and Vehicle Control History can be useful for troubleshooting.

Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM>VEHICLE CONTROL HISTORY

(Select Powertrain in Health Check and then check the time stamp data.)

Click hereEngine / Hybrid System>M20A-FXS (ENGINE CONTROL)>SFI SYSTEM>DTC CHECK / CLEAR

·

If any "Engine Malfunction" Vehicle Control History item has been stored in the hybrid vehicle control ECU assembly, make sure to clear it. However, as all Vehicle Control History items are cleared simultaneously, if any Vehicle Control History items other than "Engine Malfunction" are stored, make sure to perform any troubleshooting for them before clearing Vehicle Control History.

Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM>VEHICLE CONTROL HISTORY



HINT:

Read Freeze Frame Data using the GTS. The ECM records vehicle and driving condition information as Freeze Frame Data the moment a DTC is stored. When troubleshooting, Freeze Frame Data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.


PROCEDURE

1.CHECK TERMINAL VOLTAGE (POWER SOURCE OF MASS AIR FLOW METER)
A452295C01
0.208,0.979 0.708,1.229 0.5,0.25 1.167,1.75 1.573,1.208 true 2.667,1.75 2.031,1.208 true 2.25,1.75 1.802,1.208 true 0.125,0.125 0.438,0.323 0.313,0.198 10 false *a 0.323,1.01 0.635,1.208 0.313,0.198 10 false C84 1.042,1.76 1.417,2 0.375,0.24 10 false E2G 2.563,1.76 2.875,1.958 0.313,0.198 10 false VCC 2.167,1.76 2.479,1.958 0.313,0.198 10 false FG
*a Front view of wire harness connector
(to Mass Air Flow Meter)


a.

Disconnect the mass air flow meter connector.


b.

Turn the power switch on (IG).


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
C84-4 (VCC) - C84-2 (E2G) Power switch on (IG) 4.8 to 5.2 V
C84-3 (FG) - C84-2 (E2G) Power switch on (IG) 4.8 to 5.2 V



d.

Turn the power switch off and wait for at least 30 seconds.


e.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C84-4 (VCC) - C84-3 (FG) Power switch off 2.09 to 2.31 kΩ
C84-2 (E2G) - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

NG

2.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)
2.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)
a.

Disconnect the C84 mass air flow meter connector.


b.

Disconnect the C97 ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C84-4 (VCC) - C97-78 (VCVG) Always Below 1 Ω
C84-3 (FG) - C97-101 (VG) Always Below 1 Ω
C84-2 (E2G) - C97-79 (E2G) Always Below 1 Ω
C84-4 (VCC) or C97-78 (VCVG) - Body ground and other terminals Always 10 kΩ or higher
C84-3 (FG) or C97-101 (VG) - Body ground and other terminals Always 10 kΩ or higher
C84-2 (E2G) or C97-79 (E2G) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR