Home › Engine / Hybrid System › 2ZR-FXE (HYBRID / BATTERY CONTROL) › HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY) › from 2019.09
RM32K0E _51 Engine / Hybrid System _083958 2ZR-FXE HYBRID / BATTERY CONTROL _0404406 HYBRID CONTROL SYSTEM(for NICKEL METAL HYDRIDE BATTERY) J

2ZR-FXE HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM(for NICKEL METAL HYDRIDE BATTERY)  Shut Down Signal Circuit  


DESCRIPTION

The cause of the malfunction may be a shutdown signal.

Check whether there is a shutdown signal +B short circuit.

Related Parts Check
Area Inspection
HSDN terminal Check that the HSDN terminal voltage decreases to check for an open or short circuit while READY OFF (IG ON).
Hybrid vehicle control ECU, inverter, wire harness Check for open or short circuit in hybrid vehicle control ECU, inverter and wire harness.

SYSTEM DESCRIPTION

Power supply to the motor is cut off due to a shutdown signal sent from the hybrid vehicle control ECU to the motor generator control ECU (MG ECU).

WIRING DIAGRAM

A434057E17
2.021,0.625 2.333,0.823 0.313,0.198 10 false 6 2.021,0.927 2.333,1.125 0.313,0.198 10 false 5 2.021,1.594 2.333,1.792 0.313,0.198 10 false 22 2.021,1.885 2.333,2.083 0.313,0.198 10 false 24 2.01,2.125 2.323,2.323 0.313,0.198 10 false 23 5.125,1.479 5.438,1.677 0.313,0.198 10 false 12 5.167,1.979 5.479,2.177 0.313,0.198 10 false 6 2.771,0.75 3.979,0.958 1.208,0.208 10 false from PCU FR Fuse 5.094,1.667 5.406,1.865 0.313,0.198 10 false A48 5.438,1.521 5.854,1.698 0.417,0.177 10 false HSDN 5.438,2.177 5.969,2.427 0.531,0.25 10 false E1 5.292,2.75 7.021,2.969 1.729,0.219 10 false Hybrid Vehicle Control ECU 1.542,1.573 1.958,1.75 0.417,0.177 10 false HSDN 1.667,1.01 2.198,1.26 0.531,0.25 10 false +B2 1.729,0.75 2.26,1 0.531,0.25 10 false +B 1.563,1.99 2.094,2.24 0.531,0.25 10 false GND1 1.563,2.24 2.094,2.49 0.531,0.25 10 false GND2 0.271,2.688 0.792,2.917 0.521,0.229 10 false C65 0.271,2.844 2.281,3.063 2.01,0.219 10 false Inverter with Converter Assembly 5.135,2.156 5.417,2.354 0.281,0.198 10 false F2 2.854,2.26 3.177,2.427 0.323,0.167 10 false CA2 2.865,2.448 4.49,2.979 1.625,0.531 10 false No. 1 Engine Room Relay Block Connector 3.313,1.594 3.625,1.792 0.313,0.198 10 false 9 3.927,1.594 4.24,1.792 0.313,0.198 10 false 9

CAUTION / NOTICE / HINT

This step is referenced from the procedures for each DTC.

If the inspection results below are normal, perform the next procedure for the referenced DTC.

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery



·
A371653

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.


·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.


·
A371654C01
1.563,1.229 1.333,0.813 true 1.156,0.677 1.469,0.875 0.313,0.198 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK HYBRID VEHICLE CONTROL ECU
a.

Turn the power switch on (IG).


b.
A389500C19
1.833,0.917 2.25,1.167 0.417,0.25 1.167,0.917 1.583,1.167 0.417,0.25 1.031,2.49 1.49,1.781 true 2.26,2.5 1.833,1.719 true 0.167,0.177 0.479,0.333 0.313,0.156 10 false *a 0.781,2.5 1.208,2.677 0.427,0.177 10 false HSDN 2.219,2.531 2.49,2.729 0.271,0.198 10 false E1 1.24,0.958 1.698,1.156 0.458,0.198 10 false A48 1.958,0.969 2.25,1.167 0.292,0.198 10 false F2
*a Component with harness connected
(Hybrid Vehicle Control ECU)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A48-12 (HSDN) - F2-6 (E1) Power switch on (IG) Below 4.5 V



c.

Turn the power switch off.


Result:
Proceed to
OK
NG



OK

SHUTDOWN SIGNAL CIRCUIT NORMAL (PERFORM NEXT STEP FOR REFERENCED DTC)

NG

2.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)
2.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the inverter with converter assembly connector.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>INVERTER WITH CONVERTER>REMOVAL


c.

Disconnect the hybrid vehicle control ECU connector.


d.

Connect the cable to the negative (-) auxiliary battery terminal.


e.

Turn the power switch on (IG).


f.
A389523C03
1.25,2.25 1.667,2.5 0.417,0.25 0.5,1.167 0.917,1.417 0.417,0.25 1.906,4.333 1.5,4.073 true 2.167,2 1.729,1.396 true 2.542,0.5 1.948,1.073 true 1.385,0.26 1.844,1.063 true 1.417,3.969 1.969,3.708 true 0.74,4.354 1.271,3.99 true 0.521,0.177 0.833,0.333 0.313,0.156 10 false *a 0.188,2.167 0.5,2.323 0.313,0.156 10 false *b 2.083,2.01 2.646,2.167 0.563,0.156 10 false HSDN 1.854,4.365 2.417,4.521 0.563,0.156 10 false HSDN 2.604,0.385 3.167,0.542 0.563,0.156 10 false +B 1.094,0.156 1.656,0.313 0.563,0.156 10 false +B2 2.021,3.594 2.583,3.75 0.563,0.156 10 false +B 0.542,4.365 1.104,4.521 0.563,0.156 10 false MREL 0.583,1.219 1.042,1.417 0.458,0.198 10 false C65 1.323,2.292 1.781,2.49 0.458,0.198 10 false A48
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
*b Rear view of wire harness connector
(to Hybrid Vehicle Control ECU)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
C65-22 (HSDN) or A48-12 (HSDN) - Body ground Power switch on (IG) Below 1 V


NOTICE:

Turning the power switch on (IG) with the hybrid vehicle control ECU and inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



g.

Turn the power switch off.


h.

Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for 2 minutes or more.


i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C65-22 (HSDN) - C65-6 (+B) Power switch off 10 kΩ or higher
C65-22 (HSDN) - C65-5 (+B2) Power switch off 10 kΩ or higher
A48-12 (HSDN) - A48-4 (+B1) Power switch off 10 kΩ or higher
A48-12 (HSDN) - A48-6 (MREL) Power switch off 10 kΩ or higher



j.

Reconnect the hybrid vehicle control ECU connector.


k.

Reconnect the inverter with converter assembly connector.


Result:
Proceed to
OK
NG



OK

3.CHECK INVERTER WITH CONVERTER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.CHECK INVERTER WITH CONVERTER ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the inverter with converter assembly connector.


c.
A365592C14
0.99,0.115 1.344,0.333 0.354,0.219 0.979,0.854 0.479,0.458 true 0.813,0.917 0.281,1.031 true 1.115,1.323 1.104,1.844 true 0.104,0.083 0.417,0.281 0.313,0.198 10 false *a 1.042,0.156 1.5,0.354 0.458,0.198 10 false C65 0.969,1.875 1.583,2.073 0.615,0.198 10 false HSDN 0.073,0.958 0.385,1.156 0.313,0.198 10 false +B 0.177,0.344 0.635,0.542 0.458,0.198 10 false +B2
*a Component without harness connected
(Inverter with Converter Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C65-22 (HSDN) - C65-6 (+B) Power switch off 10 kΩ or higher
C65-22 (HSDN) - C65-5 (+B2) Power switch off 10 kΩ or higher



d.

Reconnect the inverter with converter assembly connector.


Result:
Proceed to
OK
NG



OK

NG