MALFUNCTION DESCRIPTION
These DTCs indicate that the motor inverter temperature sensor value is abnormal. The cause of this malfunction may be one of the following:
Inverter with converter assembly internal circuit malfunction
Coolant circulation abnormal (frozen or leaking, etc.)
The connectors are not connected properly
The motor generator control ECU (MG ECU), which is built into in the inverter with converter assembly, detects the temperature of the motor inverter using the motor inverter temperature sensor. If necessary, the motor generator control ECU (MG ECU) will limit inverter output to help prevent the motor inverter from overheating. The motor generator control ECU also detects malfunctions in the sensor based on the temperature sensor values. The inverter with converter assembly detects malfunctions in the motor inverter temperature sensor and its wiring.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0AED1C | Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range | Motor inverter temperature calculated by the motor generator control ECU is different from the actual temperature for 10 seconds or more, and the motor inverter temperature is too high.
(1 trip detection logic) |
·
Inverter cooling system ·
Cooling fan system ·
Inverter with converter assembly ·
Wire harness or connector |
Comes on | Master Warning
Comes on |
| P0AED1F | Drive Motor Inverter Temperature Sensor "A" Circuit Intermittent | Sudden change in motor inverter temperature sensor output or hunting:
Either of the following conditions is met: 1.
Unusual sudden change in motor inverter temperature sensor output occurs and the offset continues for a certain period of time. 2.
Unusual sudden change in motor inverter temperature sensor output occurs repeatedly. (1 trip detection logic) |
·
Inverter cooling system ·
Cooling fan system ·
Inverter with converter assembly ·
Wire harness or connector |
Comes on | Master Warning
Comes on |
| DTC No. | Data List |
|---|---|
| P0AED1C
P0AED1F |
·
Motor Inverter Temperature ·
Generator Inverter Temperature (Hybrid control system) |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
Turn the power switch on (READY) and wait for 90 seconds or more.
Check that there are no abnormalities (abnormal sounds, coolant leaks, DTC output, etc.).
Drive the vehicle for approximately 10 minutes referring to the following freeze frame data items: "Vehicle Speed".
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Refer to the wiring diagram for the Cooling System.
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0AED1C or P0AED1F only is output, or DTCs except the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Insulation Malfunction | P1C7C49 | Hybrid/EV Battery Voltage System (A/C Area) Insulation Resistance Decreased |
| P1C7D49 | Hybrid/EV Battery Voltage System (Hybrid/EV Battery Area) Insulation Resistance Decreased | |
| P1C7E49 | Hybrid/EV Battery Voltage System (Transaxle Area) Insulation Resistance Decreased | |
| P1C7F49 | Hybrid/EV Battery Voltage System (Direct Current Area) Insulation Resistance Decreased | |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Sensor and actuator circuit malfunction | P0C7396 | Motor Electronics Coolant Pump "A" Component Internal Failure |
| P314A31 | Motor Electronics Coolant Pump "A" No Signal | |
| System malfunction | P0A9300 | Inverter "A" Cooling System |
P0AED1C or P0AED1F may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Turn the power switch off.
A
B
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
If the "Cooling System" inspection results are normal, perform the next step.
| Proceed to |
|---|
| NEXT |
NEXT