Home › Engine / Hybrid System › 2ZR-FXE (HYBRID / BATTERY CONTROL) › MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY) › from 2019.09
RM32K0E _51 Engine / Hybrid System _083958 2ZR-FXE HYBRID / BATTERY CONTROL _0404407 MOTOR GENERATOR CONTROL SYSTEM(for NICKEL METAL HYDRIDE BATTERY) C

2ZR-FXE HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM(for NICKEL METAL HYDRIDE BATTERY)  P0E0012  Generator Phase U Current Sensor Circuit Short to Battery  P0E0014  Generator Phase U Current Sensor Circuit Short to Ground or Open  P0E001F  Generator Phase U Current Sensor Circuit Intermittent  P0E0412  Generator Phase V Current Sensor Circuit Short to Battery  P0E0414  Generator Phase V Current Sensor Circuit Short to Ground or Open  P0E041F  Generator Phase V Current Sensor Circuit Intermittent  P0E0812  Generator Phase W Current Sensor Circuit Short to Battery  P0E0814  Generator Phase W Current Sensor Circuit Short to Ground or Open  P0E081F  Generator Phase W Current Sensor Circuit Intermittent  


DTC SUMMARY

MALFUNCTION DESCRIPTION


These DTCs indicate that the current sensor value is abnormal. The cause of this malfunction may be one of the following:

Internal inverter malfunction

Inverter with converter assembly internal circuit malfunction


Inverter low-voltage circuit malfunction

The connectors are not connected properly



DESCRIPTION

The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors the generator inverter current sensor. These DTCs indicate the malfunction of current sensors and do not indicate a malfunction of the high-voltage system.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0E0012 Generator Phase U Current Sensor Circuit Short to Battery Malfunction in generator inverter current sensor (phase U main sensor)
(Short to +B)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Comes on Master Warning
Comes on
P0E0014 Generator Phase U Current Sensor Circuit Short to Ground or Open Malfunction in generator inverter current sensor (phase U main sensor)
(Open or short to ground)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Comes on Master Warning
Comes on
P0E001F Generator Phase U Current Sensor Circuit Intermittent Short to +B, open or short to ground detected in generator inverter current sensor (phase U main sensor) when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Does not come on Master Warning
Does not come on
P0E0412 Generator Phase V Current Sensor Circuit Short to Battery Malfunction in generator inverter current sensor (phase V main sensor)
(Short to +B)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Comes on Master Warning
Comes on
P0E0414 Generator Phase V Current Sensor Circuit Short to Ground or Open Malfunction in generator inverter current sensor (phase V main sensor)
(Open or short to ground)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Comes on Master Warning
Comes on
P0E041F Generator Phase V Current Sensor Circuit Intermittent Short to +B, open or short to ground detected in generator inverter current sensor (phase V main sensor) when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Does not come on Master Warning
Does not come on
P0E0812 Generator Phase W Current Sensor Circuit Short to Battery Malfunction in generator inverter current sensor (phase W main sensor)
(Short to +B)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Comes on Master Warning
Comes on
P0E0814 Generator Phase W Current Sensor Circuit Short to Ground or Open Malfunction in generator inverter current sensor (phase W main sensor)
(Open or short to ground)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Comes on Master Warning
Comes on
P0E081F Generator Phase W Current Sensor Circuit Intermittent Short to +B, open or short to ground detected in generator inverter current sensor (phase W main sensor) when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Does not come on Master Warning
Does not come on

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

With power switch on (IG) and wait for 5 seconds or more.

7.

Turn the power switch on (READY) with the shift lever in P and wait for 5 seconds or more.

8.

Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine.

9.

Drive the vehicle forward with the shift lever in D and drive the vehicle forward for 5 m (16 ft.) or more.

10.

Drive the vehicle backward with the shift lever in R and drive the vehicle backward for 5 m (16 ft.) or more.

11.

Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

12.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A371653

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A371654C01
1.563,1.229 1.333,0.813 true 1.156,0.677 1.469,0.875 0.313,0.198 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT (MOTOR GENERATOR CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Motor Generator / Trouble Codes.


d.

Check for DTCs.

Powertrain > Motor Generator > Trouble Codes
50001 395
Result:
Result Proceed to
P0E0012, P0E0014, P0E001F, P0E0412, P0E0414, P0E041F, P0E0812, P0E0814 and P0E081F only is output, or DTCs except the ones in the table below are also output. A
Any of the following DTCs including pending DTCs are also output. B


Malfunction Content Relevant DTC
Power source circuit malfunction P06B01C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P06D61C Sensor Reference Voltage "F" Circuit / Open
System malfunction P0A7A73 Generator Inverter Actuator Stuck Closed

HINT:

P0E0012, P0E0014, P0E001F, P0E0412, P0E0414, P0E041F, P0E0812, P0E0814 and P0E081F may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





e.

Turn the power switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>P033500

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR