HYBRID VEHICLE CONTROL ECU
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Input/Output | Condition | Specified Condition |
|---|---|---|---|---|---|
| A49-1 (+B2) - F2-6 (E1) | L - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| A49-3 (IG2) - F2-6 (E1) | BE - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| A49-8 (VCP2) - A49-18 (EPA2) | G - W | Accelerator pedal sensor assembly power source (for VPA2) | Output | Power switch on (IG) | 4.5 to 5.5 V |
| A49-9 (VCPA) - A49-20 (EPA) | BE - L | Accelerator pedal sensor assembly power source (for VPA) | Output | Power switch on (IG) | 4.5 to 5.5 V |
| A49-13 (IWP) - F2-6 (E1) | G - W-B | Inverter water pump with motor assembly signal | Output | Power switch on (READY) | Pulse generation (Waveform 1) |
| A49-14 (NIWP) - F2-6 (E1) | GR - W-B | Inverter water pump with motor assembly signal | Input | Power switch on (READY) | Pulse generation (Waveform 1) |
| A49-15 (STP) - F2-6 (E1) | SB - W-B | Stop light switch | Input | Brake pedal depressed | 11 to 14 V |
| Brake pedal released | 0 to 1.5 V | ||||
| A49-17 (LIN3) - F2-6 (E1) | Y - W-B | LIN communication signal (A/C inverter, auxiliary battery) | Input/Output | Power switch on (READY) | Pulse generation |
| A49-21 (TTA) - A49-31 (ETTA) | V - P | Transmission fluid temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A49-22 (ACCI) - F2-6 (E1) | R - W-B | ACC relay | Input | Power switch on (ACC) | 11 to 14 V |
| A49-24 (MMT) - A49-23 (MMTG) | L - BR | Motor temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A49-26 (GMT) - A49-27 (GMTG) | LG - R | Generator temperature sensor | Input | Power switch on (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Power switch on (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | ||||
| A49-28 (VPA2) - A49-18 (EPA2) | B - W | Accelerator pedal sensor assembly (for accelerator pedal position detection) | Input | Power switch on (IG), accelerator pedal released | 1.0 to 2.2 V |
| Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed | 3.4 to 5.3 V | ||||
| A49-30 (VPA) - A49-20 (EPA) | GR - L | Accelerator pedal sensor assembly (for accelerator pedal position detection) | Input | Power switch on (IG), accelerator pedal released | 0.4 to 1.4 V |
| Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed | 2.6 to 4.5 V | ||||
| A48-1 (PSFT) - F2-6 (E1) | R - W-B | Shift lever position sensor power source | Output | Power switch on (ACC) | 11 to 14 V |
| A48-2 (BL) - F2-6 (E1) | LG - W-B | Back-up light | Output | Power switch on (IG), shift lever in R | 11 to 14 V |
| A48-4 (+B1) - F2-6 (E1) | L - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| A48-6 (MREL) - F2-6 (E1) | BE - W-B | Main relay | Output | Power switch on (IG) | 11 to 14 V |
| A48-7 (IGB) - F2-6 (E1) | LG - W-B | Power source | Input | Power switch on (IG) | 11 to 14 V |
| A48-12 (HSDN) - F2-6 (E1) | B - W-B | MG ECU shutdown signal | Output | Power switch on (READY) | 0 to 1.5 V |
| A48-13 (ILK) - F2-6 (E1) | W - W-B | Interlock switch | Input | Power switch on (IG), service plug grip installed correctly | 0 to 1.5 V |
| Power switch on (IG), service plug grip not installed | 11 to 14 V | ||||
| A48-14 (DB2) - F2-6 (E1) | G - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in D or B | 6 to 14 V |
| Power switch on (IG), shift lever not in D or B | 0 to 1.5 V | ||||
| A48-15 (R) - F2-6 (E1) | L - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in R | 6 to 14 V |
| Power switch on (IG), shift lever not in R | 0 to 1.5 V | ||||
| A48-17 (PR) - F2-6 (E1) | GR - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P or R | 6 to 14 V |
| Power switch on (IG), shift lever not in P or R | 0 to 1.5 V | ||||
| A48-20 (N) - F2-6 (E1) | SB - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in N | 6 to 14 V |
| Power switch on (IG), shift lever not in N | 0 to 1.5 V | ||||
| A48-21 (P) - F2-6 (E1) | GR - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P | 6 to 14 V |
| Power switch on (IG), shift lever not in P | 0 to 1.5 V | ||||
| A48-26 (DB1) - F2-6 (E1) | W - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in D or B | 6 to 14 V |
| Power switch on (IG), shift lever not in D or B | 0 to 1.5 V | ||||
| A48-28 (ST1-) - F2-6 (E1) | R - W-B | Stop light switch signal | Input | Power switch on (IG), brake pedal depressed | 0 to 1.5 V |
| Power switch on (IG), brake pedal released | 11 to 14 V | ||||
| A48-30 (HMCL) - F2-6 (E1) | W - W-B | MG ECU communication request signal | Input/Output | Power switch on (IG) | Pulse generation (Waveform 2) |
| A48-31 (HMCH) - F2-6 (E1) | B - W-B | MG ECU communication request signal | Input/Output | Power switch on (IG) | Pulse generation (Waveform 2) |
| A48-29 (DRN5) - Body ground | G - Body ground | Shield ground | - | Always | Below 1 Ω |
| A48-34 (PNB) - F2-6 (E1) | P - W-B | Shift lever position signal | Input | Power switch on (IG), shift lever in P, N, or B | 6 to 14 V |
| F2-1 (SMRG) - F2-5 (E01) | P - W-B | System main relay operation signal | Output | Power switch on (IG) → Power switch on (READY) | Pulse generation (Waveform 3) |
| F2-3 (SMRP) - F2-5 (E01) | LG - W-B | System main relay operation signal | Output | Power switch on (IG) → Power switch on (READY) | Pulse generation (Waveform 3) |
| F2-4 (SMRB) - F2-5 (E01) | BE - W-B | System main relay operation signal | Output | Power switch on (IG) → Power switch on (READY) | Pulse generation (Waveform 3) |
| F2-5 (E01) - Body ground | W-B - Body ground | Ground | - | Always | Below 1 Ω |
| F2-8 (INDR) - F2-6 (E1) | R - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in R | 0 to 3.2 V |
| Power switch on (IG), shift lever not in R | 11 to 14 V | ||||
| F2-9 (ST2) - F2-6 (E1) | B - W-B | Starter signal | Input | Power switch on (IG) | 0 to 1.5 V |
| F2-34 (CA4H) - F2-6 (E1) | L - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation (Waveform 4) |
| F2-35 (CA4L) - F2-6 (E1) | P - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation (Waveform 4) |
| F3-3 (BATT) - F2-6 (E1) | B - W-B | Constant power source | Input | Power switch on (IG) | 11 to 14 V |
| Power switch on (READY) | 11 to 15.5 V | ||||
| F3-4 (E12) - Body ground | W-B - Body ground | Ground | - | Always | Below 1 Ω |
| F3-5 (E02) - Body ground | W-B - Body ground | Ground | - | Always | Below 1 Ω |
| F3-7 (PLKC) - F2-6 (E1) | LG - W-B | Shift lock release request signal | Output | Power switch on (READY), brake pedal depressed | 11 to 14 V |
| Power switch on (READY), brake pedal released | 0 to 1.5 V | ||||
| F3-10 (INDB) - F2-6 (E1) | B - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in B | 0 to 3.2 V |
| Power switch on (IG), shift lever not in B | 11 to 14 V | ||||
| F3-11 (INDD) - F2-6 (E1) | V - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in D | 0 to 3.2 V |
| Power switch on (IG), shift lever not in D | 11 to 14 V | ||||
| F3-12 (INDN) - F2-6 (E1) | GR - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in N | 0 to 3.2 V |
| Power switch on (IG), shift lever not in N | 11 to 14 V | ||||
| F3-13 (INDP) - F2-6 (E1) | G - W-B | Shift position indicator signal | Input | Power switch on (IG), shift lever in P | 0 to 3.2 V |
| Power switch on (IG), shift lever not in P | 11 to 14 V | ||||
| F3-14 (ABFS) - F2-6 (E1) | B - W-B | Airbag activation signal | Input | Power switch on (READY) | Pulse generation (Waveform 5) |
| F3-15 (EVSW) - F2-6 (E1) | R - W-B | EV drive mode switch (combination switch assembly) signal | Input | Power switch on (IG), EV drive mode switch (combination switch assembly) not operated | 11 to 14 V |
| Power switch on (IG), EV drive mode switch (combination switch assembly) operated | 0 to 1.5 V | ||||
| F3-24 (CA1L) - F2-6 (E1) | P - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation (Waveform 6) |
| F3-25 (CA1H) - F2-6 (E1) | L - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation (Waveform 6) |
| F3-30 (CA3N) - F2-6 (E1) | W - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation (Waveform 7) |
| F3-31 (CA3P) - F2-6 (E1) | R - W-B | CAN communication signal | Input/Output | Power switch on (IG) | Pulse generation (Waveform 7) |
Oscilloscope waveforms
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.
Waveform 1 (Inverter water pump assembly signal)
| Item | Content |
|---|---|
| Terminal | CH1: A49-13 (IWP) - F2-6 (E1)
CH2: A49-14 (NIWP) - F2-6 (E1) |
| Equipment Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Power switch on (READY) |
The duty of the IWP signal and the frequency of the NIWP signal change according to the coolant (for inverter) temperature.
Waveform 2 (Communication signal)
| Item | Content |
|---|---|
| Terminal | CH1: A48-31 (HMCH) - F2-6 (E1)
CH2: A48-30 (HMCL) - F2-6 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 3 (System main relay operation signal)
| Item | Content |
|---|---|
| Terminal | CH1: F2-3 (SMRP) - F2-5 (E01)
CH2: F2-4 (SMRB) - F2-5 (E01) CH3: F2-1 (SMRG) - F2-5 (E01) |
| Equipment Setting | 10 V/DIV., 200 ms./DIV. |
| Condition | Power switch on (IG) → Power switch on (READY) |
Waveform 4 (CAN communication signal)
| Item | Content |
|---|---|
| Terminal | CH1: F2-34 (CA4H) - F2-6 (E1)
CH2: F2-35 (CA4L) - F2-6 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 5 (Airbag activation signal)
| Item | Content |
|---|---|
| Terminal | F3-14 (ABFS) - F2-6 (E1) |
| Equipment Setting | 5 V/DIV., 125 ms./DIV. |
| Condition | Power switch on (READY) |
Waveform 6 (CAN communication signal)
| Item | Content |
|---|---|
| Terminal | CH1: F3-25 (CA1H) - F2-6 (E1)
CH2: F3-24 (CA1L) - F2-6 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 7 (CAN communication signal)
| Item | Content |
|---|---|
| Terminal | CH1: F3-31 (CA3P) - F2-6 (E1)
CH2: F3-30 (CA3N) - F2-6 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).