Home › Engine / Hybrid System › 2ZR-FXE (HYBRID / BATTERY CONTROL) › HYBRID CONTROL SYSTEM (for LITHIUM-ION BATTERY) › from 2019.09
RM32K0E _51 Engine / Hybrid System _083958 2ZR-FXE HYBRID / BATTERY CONTROL _0404408 HYBRID CONTROL SYSTEM(for LITHIUM-ION BATTERY) U

2ZR-FXE HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM(for LITHIUM-ION BATTERY)  TERMINALS OF ECU  


HYBRID VEHICLE CONTROL ECU


C297329E11
1.344,1.458 1.844,1.708 0.5,0.25 2.667,1.469 3.167,1.719 0.5,0.25 4.198,1.469 4.698,1.719 0.5,0.25 5.469,1.458 5.969,1.708 0.5,0.25 1.469,1.5 1.823,1.656 0.354,0.156 10 false A49 2.802,1.5 3.177,1.698 0.375,0.198 10 false A48 4.365,1.51 4.865,1.698 0.5,0.188 10 false F2 5.635,1.51 6.042,1.677 0.406,0.167 10 false F3

Terminal No.
(Symbol)
Wiring Color Terminal Description Input/Output Condition Specified Condition
A49-1 (+B2) - F2-6 (E1) L - W-B Power source Input Power switch on (IG) 11 to 14 V
A49-3 (IG2) - F2-6 (E1) BE - W-B Power source Input Power switch on (IG) 11 to 14 V
A49-8 (VCP2) - A49-18 (EPA2) G - W Accelerator pedal sensor assembly power source (for VPA2) Output Power switch on (IG) 4.5 to 5.5 V
A49-9 (VCPA) - A49-20 (EPA) BE - L Accelerator pedal sensor assembly power source (for VPA) Output Power switch on (IG) 4.5 to 5.5 V
A49-13 (IWP) - F2-6 (E1) G - W-B Inverter water pump with motor assembly signal Output Power switch on (READY) Pulse generation (Waveform 1)
A49-14 (NIWP) - F2-6 (E1) GR - W-B Inverter water pump with motor assembly signal Input Power switch on (READY) Pulse generation (Waveform 1)
A49-15 (STP) - F2-6 (E1) SB - W-B Stop light switch Input Brake pedal depressed 11 to 14 V
Brake pedal released 0 to 1.5 V
A49-17 (LIN3) - F2-6 (E1) Y - W-B LIN communication signal (A/C inverter, auxiliary battery) Input/Output Power switch on (READY) Pulse generation
A49-21 (TTA) - A49-31 (ETTA) V - P Transmission fluid temperature sensor Input Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
A49-22 (ACCI) - F2-6 (E1) R - W-B ACC relay Input Power switch on (ACC) 11 to 14 V
A49-24 (MMT) - A49-23 (MMTG) L - BR Motor temperature sensor Input Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
A49-26 (GMT) - A49-27 (GMTG) LG - R Generator temperature sensor Input Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
A49-28 (VPA2) - A49-18 (EPA2) B - W Accelerator pedal sensor assembly (for accelerator pedal position detection) Input Power switch on (IG), accelerator pedal released 1.0 to 2.2 V
Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed 3.4 to 5.3 V
A49-30 (VPA) - A49-20 (EPA) GR - L Accelerator pedal sensor assembly (for accelerator pedal position detection) Input Power switch on (IG), accelerator pedal released 0.4 to 1.4 V
Power switch on (IG), engine stopped, shift lever in P, accelerator pedal fully depressed 2.6 to 4.5 V
A48-1 (PSFT) - F2-6 (E1) R - W-B Shift lever position sensor power source Output Power switch on (ACC) 11 to 14 V
A48-2 (BL) - F2-6 (E1) LG - W-B Back-up light Output Power switch on (IG), shift lever in R 11 to 14 V
A48-4 (+B1) - F2-6 (E1) L - W-B Power source Input Power switch on (IG) 11 to 14 V
A48-6 (MREL) - F2-6 (E1) BE - W-B Main relay Output Power switch on (IG) 11 to 14 V
A48-7 (IGB) - F2-6 (E1) LG - W-B Power source Input Power switch on (IG) 11 to 14 V
A48-12 (HSDN) - F2-6 (E1) B - W-B MG ECU shutdown signal Output Power switch on (READY) 0 to 1.5 V
A48-13 (ILK) - F2-6 (E1) W - W-B Interlock switch Input Power switch on (IG), service plug grip installed correctly 0 to 1.5 V
Power switch on (IG), service plug grip not installed 11 to 14 V
A48-14 (DB2) - F2-6 (E1) G - W-B Shift lever position signal Input Power switch on (IG), shift lever in D or B 6 to 14 V
Power switch on (IG), shift lever not in D or B 0 to 1.5 V
A48-15 (R) - F2-6 (E1) L - W-B Shift lever position signal Input Power switch on (IG), shift lever in R 6 to 14 V
Power switch on (IG), shift lever not in R 0 to 1.5 V
A48-17 (PR) - F2-6 (E1) GR - W-B Shift lever position signal Input Power switch on (IG), shift lever in P or R 6 to 14 V
Power switch on (IG), shift lever not in P or R 0 to 1.5 V
A48-20 (N) - F2-6 (E1) SB - W-B Shift lever position signal Input Power switch on (IG), shift lever in N 6 to 14 V
Power switch on (IG), shift lever not in N 0 to 1.5 V
A48-21 (P) - F2-6 (E1) GR - W-B Shift lever position signal Input Power switch on (IG), shift lever in P 6 to 14 V
Power switch on (IG), shift lever not in P 0 to 1.5 V
A48-26 (DB1) - F2-6 (E1) W - W-B Shift lever position signal Input Power switch on (IG), shift lever in D or B 6 to 14 V
Power switch on (IG), shift lever not in D or B 0 to 1.5 V
A48-28 (ST1-) - F2-6 (E1) R - W-B Stop light switch signal Input Power switch on (IG), brake pedal depressed 0 to 1.5 V
Power switch on (IG), brake pedal released 11 to 14 V
A48-30 (HMCL) - F2-6 (E1) W - W-B MG ECU communication request signal Input/Output Power switch on (IG) Pulse generation (Waveform 2)
A48-31 (HMCH) - F2-6 (E1) B - W-B MG ECU communication request signal Input/Output Power switch on (IG) Pulse generation (Waveform 2)
A48-29 (DRN5) - Body ground G - Body ground Shield ground - Always Below 1 Ω
A48-34 (PNB) - F2-6 (E1) P - W-B Shift lever position signal Input Power switch on (IG), shift lever in P, N, or B 6 to 14 V
F2-1 (SMRG) - F2-5 (E01) P - W-B System main relay operation signal Output Power switch on (IG) → Power switch on (READY) Pulse generation (Waveform 3)
F2-3 (SMRP) - F2-5 (E01) LG - W-B System main relay operation signal Output Power switch on (IG) → Power switch on (READY) Pulse generation (Waveform 3)
F2-4 (SMRB) - F2-5 (E01) BE - W-B System main relay operation signal Output Power switch on (IG) → Power switch on (READY) Pulse generation (Waveform 3)
F2-5 (E01) - Body ground W-B - Body ground Ground - Always Below 1 Ω
F2-8 (INDR) - F2-6 (E1) R - W-B Shift position indicator signal Input Power switch on (IG), shift lever in R 0 to 3.2 V
Power switch on (IG), shift lever not in R 11 to 14 V
F2-9 (ST2) - F2-6 (E1) B - W-B Starter signal Input Power switch on (IG) 0 to 1.5 V
F2-34 (CA4H) - F2-6 (E1) L - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation (Waveform 4)
F2-35 (CA4L) - F2-6 (E1) P - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation (Waveform 4)
F3-3 (BATT) - F2-6 (E1) B - W-B Constant power source Input Power switch on (IG) 11 to 14 V
Power switch on (READY) 11 to 15.5 V
F3-4 (E12) - Body ground W-B - Body ground Ground - Always Below 1 Ω
F3-5 (E02) - Body ground W-B - Body ground Ground - Always Below 1 Ω
F3-7 (PLKC) - F2-6 (E1) LG - W-B Shift lock release request signal Output Power switch on (READY), brake pedal depressed 11 to 14 V
Power switch on (READY), brake pedal released 0 to 1.5 V
F3-10 (INDB) - F2-6 (E1) B - W-B Shift position indicator signal Input Power switch on (IG), shift lever in B 0 to 3.2 V
Power switch on (IG), shift lever not in B 11 to 14 V
F3-11 (INDD) - F2-6 (E1) V - W-B Shift position indicator signal Input Power switch on (IG), shift lever in D 0 to 3.2 V
Power switch on (IG), shift lever not in D 11 to 14 V
F3-12 (INDN) - F2-6 (E1) GR - W-B Shift position indicator signal Input Power switch on (IG), shift lever in N 0 to 3.2 V
Power switch on (IG), shift lever not in N 11 to 14 V
F3-13 (INDP) - F2-6 (E1) G - W-B Shift position indicator signal Input Power switch on (IG), shift lever in P 0 to 3.2 V
Power switch on (IG), shift lever not in P 11 to 14 V
F3-14 (ABFS) - F2-6 (E1) B - W-B Airbag activation signal Input Power switch on (READY) Pulse generation (Waveform 5)
F3-15 (EVSW) - F2-6 (E1) R - W-B EV drive mode switch (combination switch assembly) signal Input Power switch on (IG), EV drive mode switch (combination switch assembly) not operated 11 to 14 V
Power switch on (IG), EV drive mode switch (combination switch assembly) operated 0 to 1.5 V
F3-24 (CA1L) - F2-6 (E1) P - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation (Waveform 6)
F3-25 (CA1H) - F2-6 (E1) L - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation (Waveform 6)
F3-30 (CA3N) - F2-6 (E1) W - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation (Waveform 7)
F3-31 (CA3P) - F2-6 (E1) R - W-B CAN communication signal Input/Output Power switch on (IG) Pulse generation (Waveform 7)

a.

Oscilloscope waveforms

HINT:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


i.
A415999E04
0.365,0.854 0.823,1.052 0.458,0.198 10 false CH1 0.375,1.417 0.833,1.615 0.458,0.198 10 false CH2 2.958,1.635 3.281,1.917 0.323,0.281 10 false GND 2.958,0.854 3.281,1.135 0.323,0.281 10 false GND

Waveform 1 (Inverter water pump assembly signal)

Item Content
Terminal CH1: A49-13 (IWP) - F2-6 (E1)
CH2: A49-14 (NIWP) - F2-6 (E1)
Equipment Setting 5 V/DIV., 20 ms./DIV.
Condition Power switch on (READY)

HINT:

The duty of the IWP signal and the frequency of the NIWP signal change according to the coolant (for inverter) temperature.



ii.
A284438E06
2.969,1.198 3.427,1.396 0.458,0.198 10 GND 2.969,1.573 3.427,1.771 0.458,0.198 10 GND 0.396,0.646 0.854,0.844 0.458,0.198 10 CH1 0.396,1.229 0.854,1.427 0.458,0.198 10 CH2

Waveform 2 (Communication signal)

Item Content
Terminal CH1: A48-31 (HMCH) - F2-6 (E1)
CH2: A48-30 (HMCL) - F2-6 (E1)
Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



iii.
C206010E10
2.958,0.656 3.292,0.896 0.333,0.24 10 false GND 2.958,1.042 3.292,1.281 0.333,0.24 10 false GND 2.958,1.427 3.292,1.667 0.333,0.24 10 false GND 0.271,0.573 0.594,0.781 0.323,0.208 10 false CH1 0.281,0.948 0.615,1.188 0.333,0.24 10 false CH2 0.292,1.313 0.625,1.552 0.333,0.24 10 false CH3

Waveform 3 (System main relay operation signal)

Item Content
Terminal CH1: F2-3 (SMRP) - F2-5 (E01)
CH2: F2-4 (SMRB) - F2-5 (E01)
CH3: F2-1 (SMRG) - F2-5 (E01)
Equipment Setting 10 V/DIV., 200 ms./DIV.
Condition Power switch on (IG) → Power switch on (READY)


iv.
A284438E08
2.969,1.198 3.427,1.396 0.458,0.198 10 GND 2.969,1.573 3.427,1.771 0.458,0.198 10 GND 0.396,0.646 0.854,0.844 0.458,0.198 10 CH1 0.396,1.229 0.854,1.427 0.458,0.198 10 CH2

Waveform 4 (CAN communication signal)

Item Content
Terminal CH1: F2-34 (CA4H) - F2-6 (E1)
CH2: F2-35 (CA4L) - F2-6 (E1)
Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



v.
A298836E01
3.01,1.052 3.396,1.25 0.385,0.198 10 GND

Waveform 5 (Airbag activation signal)

Item Content
Terminal F3-14 (ABFS) - F2-6 (E1)
Equipment Setting 5 V/DIV., 125 ms./DIV.
Condition Power switch on (READY)


vi.
A284438E06
2.969,1.198 3.427,1.396 0.458,0.198 10 GND 2.969,1.573 3.427,1.771 0.458,0.198 10 GND 0.396,0.646 0.854,0.844 0.458,0.198 10 CH1 0.396,1.229 0.854,1.427 0.458,0.198 10 CH2

Waveform 6 (CAN communication signal)

Item Content
Terminal CH1: F3-25 (CA1H) - F2-6 (E1)
CH2: F3-24 (CA1L) - F2-6 (E1)
Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



vii.
A284438E07
2.969,1.198 3.427,1.396 0.458,0.198 10 GND 2.969,1.573 3.427,1.771 0.458,0.198 10 GND 0.396,0.646 0.854,0.844 0.458,0.198 10 CH1 0.396,1.229 0.854,1.427 0.458,0.198 10 CH2

Waveform 7 (CAN communication signal)

Item Content
Terminal CH1: F3-31 (CA3P) - F2-6 (E1)
CH2: F3-30 (CA3N) - F2-6 (E1)
Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).