Home › Engine / Hybrid System › 2ZR-FXE (HYBRID / BATTERY CONTROL) › HYBRID CONTROL SYSTEM (for LITHIUM-ION BATTERY) › from 2019.09
RM32K0E _51 Engine / Hybrid System _083958 2ZR-FXE HYBRID / BATTERY CONTROL _0404408 HYBRID CONTROL SYSTEM(for LITHIUM-ION BATTERY) U

2ZR-FXE HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM(for LITHIUM-ION BATTERY)  DATA LIST / ACTIVE TEST  


DATA LIST


NOTICE:
·

Some Data List values may vary significantly if there are slight differences in the environment in which the vehicle is operating when measurements are obtained. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.

·

In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under identical conditions in order to reach an overall judgment by comparing all the items in the Data List.



a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Hybrid Control / Data List.


e.

Check the results by referring to the following table.

HINT:
·

When reviewing Data List information, try to select only the specific Data List items related to the inspection being performed. If all items are selected when checking the Data List, the interval between updates for each item will be longer, resulting in delayed or incorrect data.

·

Using a custom list makes it possible to easily select smaller groups of related Data List items.

·

The following custom lists are available:

-

Primary

-

Hybrid Battery

-

Hybrid Battery Temperature

-

Inverter

-

Hybrid Coolant Temperature

-

Shift

-

Insulation Abnormal

-

SMR

-

Ready ON

-

DC/DC Converter

-

Auxiliary Battery

-

Resolver Learning




Powertrain > Hybrid Control > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Vehicle Speed Vehicle speed Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph)
·

Vehicle stopped: 0 km/h (0 mph)

·

While driving at a constant speed: No significant fluctuation


-
Target Engine Power Target engine power Min.: 0 W, Max.: 655350 W While driving with the engine running:
Varies depending on vehicle operating conditions
Requested engine power by hybrid vehicle control ECU to ECM
·

Hybrid vehicle control ECU

·

Motor generator control ECU

·

ECM

·

Engine


Execute Engine Power Execute engine power Min.: 0 W, Max.: 655350 W While driving with the engine running:
Varies depending on vehicle operating conditions
-
Target Engine Revolution Target engine revolution - While driving with the engine running:
Varies depending on vehicle operating conditions
Target engine speed requested by hybrid vehicle control ECU to ECM
·

Hybrid vehicle control ECU

·

ECM

·

Engine


Engine Speed Engine speed -
·

Engine stopped: 0 rpm

·

While engine running at a constant speed: No significant fluctuation


-
Calculate Load Calculate load Min.: 0.00%, Max.: 100.00% - Value increases in proportion to increase in load
·

Throttle valve status

·

Air cleaner condition


Coolant Temperature Engine coolant temperature Min.: -40°C (-40°F), Max.: 215°C (419°F)
·

Cold start→Fully warmed up: Gradually rises

·

After warming up: 75 to 100°C (167 to 212°F)


-
Starter Switch Signal Starter ON / OFF signal ON or OFF Starter ON:
ON
-
Engine Idling Request Engine idling request ON or OFF Requesting idle:
ON
·

ECM

·

Hybrid vehicle control ECU


Engine Start Request (A/C) Engine idling request from air conditioning amplifier assembly ON or OFF While an engine start is requested from the air conditioning amplifier assembly:
ON
Air conditioning amplifier assembly
Engine Start Request (Engine Warm-up) Engine idling request to warm up engine ON or OFF
·

While an engine warm-up is requested: ON

·

After the engine is warmed up: OFF


·

Hybrid vehicle control ECU

·

ECM


Engine Start Request (Hybrid Battery Charging) Engine idling request to charge HV battery ON or OFF Requesting HV battery charging:
ON
·

Battery ECU assembly

·

HV battery


Engine Mode Engine status Stop / Stop Process / Startup Process / Running
·

Engine stopped: Stop

·

Engine stopping: Stop Process

·

While the engine starting: Startup Process

·

Engine running: Running


·

Hybrid vehicle control ECU

·

ECM

·

Hybrid vehicle transaxle assembly


Engine Run Time Elapsed time after starting engine Min.: 0 sec, Max.: 65535 sec Elapsed time after starting engine Elapsed time from initial engine start until the power switch is turned off.
Engine Stop Request Engine stop request ON or OFF Requesting engine stop:
ON
·

ECM

·

Hybrid vehicle control ECU


Engine Stop F/C Status Engine fuel cut status ON or OFF While engine fuel cut:
ON
·

ECM

·

Hybrid vehicle control ECU


Lack of Fuel Lack of fuel ON or OFF Fuel level low:
ON
-
Accelerator Position Accelerator pedal depressed angle Min.: 0.0%, Max.: 100.0%
·

Accelerator pedal fully depressed: 100%

·

Accelerator pedal released: 0%


Accelerator pedal sensor assembly
Accelerator Pedal Status Accelerator pedal status ON or OFF
·

Accelerator pedal depressed: ON

·

Accelerator pedal released: OFF


Accelerator pedal sensor assembly
Accelerator Position Sensor No.1 Voltage % Accelerator pedal position sensor No. 1 Min.: 0.00%, Max.: 100.00% Accelerator pedal depressed:
Changes with accelerator pedal position
Sensor voltage is multiplied by 20 and displayed as a percentage

Accelerator pedal sensor assembly


Accelerator Position Sensor No.2 Voltage % Accelerator pedal position sensor No. 2 Min.: 0.00%, Max.: 100.00% Accelerator pedal depressed:
Changes with accelerator pedal position
Sensor voltage is multiplied by 20 and displayed as a percentage

Accelerator pedal sensor assembly


Throttle Position Sensor No.1 Voltage % Throttle position sensor Min.: 0.00%, Max.: 100.00% - Throttle valve status
Master Cylinder Control Torque Braking torque equivalent to master cylinder brake fluid pressure
(Total braking torque)
- Brake pedal depressed:
Changes with the brake pedal pressure
Master cylinder brake fluid pressure control torque = hydraulic brake control torque + regenerative brake torque

Master cylinder pressure sensor


Brake Cancel Switch Brake cancel switch ON or OFF
·

Brake pedal depressed: OFF

·

Brake pedal released: ON


-
Shift Position Current shift state P / R / N / D / B Matches currently selected shift position:
P, R, N, D or B
Shift state
Shift Position (Meter) Shift position of meter display Not Displayed / P / R / N / D / B Matches currently selected shift position:
P, R, N, D or B
Shift state
Shift Switch Status (N,P Position) Shift position status (N or P position) ON or OFF Shift lever in P or N:
ON
Shift state
Shift Position Sensor (PNB) Shift lever position sensor ON or OFF
·

Shift lever in P, N or B: ON

·

Shift lever in any position other than P, N or B: OFF


Shift lever position sensor
Shift Position Sensor (PR) Shift lever position sensor ON or OFF
·

Shift lever in P or R: ON

·

Shift lever in any position other than P or R: OFF


Shift lever position sensor
Shift Position Sensor (DB1) Shift lever position sensor ON or OFF
·

Shift lever in D or B: ON

·

Shift lever in any position other than D or B: OFF


Shift lever position sensor
Shift Position Sensor (DB2) Shift lever position sensor ON or OFF
·

Shift lever in D or B: ON

·

Shift lever in any position other than D or B: OFF


Shift lever position sensor
Shift Position Sensor (N) Shift lever position sensor ON or OFF
·

Shift lever in N: ON

·

Shift lever in any position other than N: OFF


Shift lever position sensor
Shift Position Sensor (R) Shift lever position sensor ON or OFF
·

Shift lever in R: ON

·

Shift lever in any position other than R: OFF


Shift lever position sensor
Shift Position Sensor (P) Shift lever position sensor ON or OFF
·

Shift lever in P: ON

·

Shift lever in any position other than P: OFF


Shift lever position sensor
Shift Lock Release Request Shift lock release request ON or OFF
·

Brake pedal depressed: ON

·

Other than above: OFF


-
Transaxle Oil Temperature Hybrid vehicle transaxle oil temperature Min.: -40°C (-40°F), Max.: 215°C (419°F)
·

Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F)

·

While driving: Varies depending on vehicle operating conditions


-
Transaxle Oil Temperature Sensor Voltage Hybrid vehicle transaxle oil temperature sensor voltage Min: 0.00 V, Max: 4.99 V - -
FR Wheel Speed Front wheel speed RH Min.: 0.00 km/h, Max.: 327.67 km/h
·

Vehicle stopped: 0 km/h (0 mph)

·

Vehicle being driven at a constant speed: No large fluctuations in displayed speed


-
FL Wheel Speed Front wheel speed LH Min.: 0.00 km/h, Max.: 327.67 km/h
·

Vehicle stopped: 0 km/h (0 mph)

·

Vehicle being driven at a constant speed: No large fluctuations in displayed speed


-
RR Wheel Speed Rear wheel speed RH Min.: 0.00 km/h, Max.: 327.67 km/h
·

Vehicle stopped: 0 km/h (0 mph)

·

Vehicle being driven at a constant speed: No large fluctuations in displayed speed


-
RL Wheel Speed Rear wheel speed LH Min.: 0.00 km/h, Max.: 327.67 km/h
·

Vehicle stopped: 0 km/h (0 mph)

·

Vehicle being driven at a constant speed: No large fluctuations in displayed speed


-
Atmospheric Pressure Atmospheric pressure Min.: 0 kPa, Max.: 255 kPa Constant:
Atmosphere pressure
-
Intake Manifold Absolute Pressure Intake manifold pressure of engine Min.: 0.00 kPa, Max.: 255.00 kPa Power switch on (IG) or engine stopped:
Atmosphere pressure
Values less than atmospheric pressure are indicated while the engine is running
Ambient Temperature Ambient air temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) Power switch on (IG):
Same as ambient air temperature
Ambient temperature sensor
Intake Air Temperature Engine intake air temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) Constant:
Almost same as ambient air temperature
-
BATT Voltage Auxiliary battery voltage
(Battery ECU assembly power source voltage)
Min.: 0.00 V, Max.: 16.00 V 11.00 to 15.00 V BATT terminal
Smoothed Value of BATT Voltage Smoothed value of auxiliary battery voltage Min.: 0.000 V, Max.: 16.000 V 11.000 to 15.000 V Hybrid vehicle control ECU
Warmup Cycle Cleared DTC The number of times the engine is warmed up after clearing DTCs Min.: 0, Max.: 255 MIL OFF, engine coolant temperature increases from below 22°C (71.6°F) before starting the engine to above 70°C (158°F) after starting the engine:
Increases once
-
Distance from DTC Cleared Drive distance after clearing DTCs Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) - -
Time after DTC Cleared Elapsed time after clearing DTCs Min.: 0 min, Max.: 65535 min - Time elapsed after DTCs are cleared (Not counted when the power switch is off).
MIL MIL status ON or OFF - -
Running Time from MIL ON Running time from MIL on Min.: 0 min, Max.: 65535 min - -
Total Distance Traveled Drive total distance Min.: 0, Max.: 16777215 - -
Total Distance Traveled - Unit Drive total distance unit km or mile - -
MIL ON Run Distance Drive distance from MIL on Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) - -
Number of Emission DTC Emissions-related DTCs Min.: 0, Max.: 127 - -
IGB Signal Status IGB signal status ON or OFF Power switch on (IG) or on (READY):
ON
IGB terminal
IG2 Signal Status IG2 signal status ON or OFF Power switch on (IG) or on (READY):
ON
IG2 terminal
Ready Signal Ready signal status ON or OFF Power switch on (READY):
ON
-
HV Activate Condition Hybrid vehicle control system power source mode status Normal / Remote Air Control System / Remote
·

Hybrid vehicle control system started using power switch: Normal

·

Hybrid vehicle control system started using remote air control system function: Remote Air Control System

·

Hybrid vehicle control system started using remote starter: Remote


-
MG Activate Condition Motor generator control system status ON or OFF Power switch on (IG) or on (READY):
ON
-
DSS Control Status Control status of DSS (Driving Support System) Not Control / Available / Unavailable / Disable - -
Generate Torque (Request from DSS) Generated drive torque requested from DSS (Driving Support System) Min.: -4096.00 Nm, Max.: 4095.87 Nm - -
Primary Driving Force Adjustment Result Result of adjustment between drive force of DSS (Driving Support System) and drive force requested by accelerator pedal operation Accelerator / DSS
·

Drive force requested by Accelerator pedal operation selected: Accelerator

·

Drive force requested by DSS selected: DSS


-
SMRG Status Operating state of SMRG
(primary circuit monitor)
ON or OFF Power switch on (READY):
ON
·

HV battery junction block assembly

·

Wire harness


SMRG Control Status Commanded state of SMRG ON or OFF Power switch on (READY):
ON
·

HV battery junction block assembly

·

Wire harness


SMRB Status Operating state of SMRB
(primary circuit monitor)
ON or OFF Power switch on (READY):
ON
·

HV battery junction block assembly

·

Wire harness


SMRB Control Status Commanded state of SMRB ON or OFF Power switch on (READY):
ON
·

HV battery junction block assembly

·

Wire harness


SMRP Status Operating state of SMRP
(primary circuit monitor)
ON or OFF
·

Immediately after the power switch on (ST-ON) state occurred: ON

·

After the above timing: OFF


Cannot be confirmed using the GTS. Use an oscilloscope.
·

HV battery junction block assembly

·

Wire harness


SMRP Control Status Commanded state of SMRP ON or OFF
·

Immediately after the power switch on (ST-ON) state occurred: ON

·

After the above timing: OFF


Cannot be confirmed using the GTS. Use an oscilloscope.
·

HV battery junction block assembly

·

Wire harness


A/C Consumption Power A/C consumption power Min.: 0.00 kW, Max.: 12.75 kW While the air conditioning system is operating:
0 to 5.00 kW
Air conditioning system
EV Mode EV mode transition availability ON or OFF In EV mode:
ON
-
EV Mode Switch EV drive mode switch (electric parking brake switch assembly) condition ON or OFF
·

EV drive mode switch (electric parking brake switch assembly) being pushed and held: ON

·

EV drive mode switch (electric parking brake switch assembly) not operated: OFF


Pattern Select Switch EV Mode Circuit
Inter Lock Switch Interlock switch condition ON or OFF Power switch on (IG), service plug grip not installed:
ON
ILK terminal
Inter Lock Switch (MG) Interlock switch condition ON or OFF Power switch on (IG), inverter cover not installed:
ON
Inverter with converter assembly
Stop Light Switch Stop light switch assembly condition ON or OFF Brake pedal depressed:
ON
-
Back Up Light Relay Back up light switch condition ON or OFF Shift lever in R:
ON
-
VSC/TRC OFF Switch VSC condition OFF / TRC OFF Mode / TRC/VSC OFF Mode - -
Airbag Status (Collision) Airbag sensor assembly collision detection ON or OFF Collision detection by the Airbag sensor assembly:
ON
-
Airbag Status (Collision) (CAN) Airbag sensor assembly collision detection (CAN) Normal / Collision from Back / Airbag Circuit Abnormal / Safing / Collision from Front or Side - -
Airbag Status (Safing) Safing state of the airbag sensor assembly ON or OFF When safing state of the airbag sensor assembly:
ON
-
Airbag Status (Normal) Control state of airbag sensor assembly ON or OFF When the airbag sensor assembly is operating normally:
ON
-
Crank Position Crankshaft position Min.: -128 deg (CA), Max.: 127 deg (CA) - -
TC Terminal TC terminal state ON or OFF - Active Test item [Connect the TC and TE1] support data.
Body Control with Torque Demand Body Control with Torque Demand status ON or OFF Under the Body Control with Torque Demand:
ON
-
Generator Revolution Generator (MG1) speed (detected by resolver sensor) Min.: -32768 rpm, Max.: 32767 rpm During charge or discharge:
Varies depending on vehicle operating conditions
Generator (MG1) speed is set to obtain requested target engine speed
·

Hybrid vehicle transaxle assembly

·

Inverter with converter assembly


Target Generator Torque Generator (MG1) torque request value Min.: -4096.00 Nm, Max.: 4095.87 Nm During charge or discharge:
Varies depending on vehicle operating conditions
·

Hybrid vehicle control ECU

·

Hybrid vehicle transaxle assembly

·

Inverter with converter assembly


Generator Torque Generator (MG1) torque execution value Min.: -4096.00 Nm, Max.: 4095.87 Nm One second after engine automatically starts with shift lever in P (Condition before engine start: Power switch on (READY), engine stopped, A/C fan speed high and headlights on):
Within +/- 20% of Target Generator Torque
·

Hybrid vehicle control ECU

·

Hybrid vehicle transaxle assembly

·

Inverter with converter assembly


Motor Revolution Motor (MG2) speed (detected by resolver sensor) Min.: -32768 rpm, Max.: 32767 rpm While driving:
Varies depending on vehicle speed
Motor (MG2) speed changes in proportion to vehicle speed. Motor (MG2) speed is not influenced by accelerator pedal opening angle, engine speed or generator (MG1) speed.
·

Hybrid vehicle transaxle assembly

·

Inverter with converter assembly


Target Motor Torque Motor (MG2) torque request value Min.: -4096.00 Nm, Max.: 4095.87 Nm While driving:
Varies depending on vehicle operating conditions
·

Hybrid vehicle control ECU

·

Hybrid vehicle transaxle assembly

·

Inverter with converter assembly


Motor Torque Motor (MG2) torque execution value Min.: -4096.00 Nm, Max.: 4095.87 Nm After full-load acceleration with power switch on (READY) and engine stopped:
Within +/-20% of Target Motor Torque
·

Hybrid vehicle control ECU

·

Hybrid vehicle transaxle assembly

·

Inverter with converter assembly


Request Motor Regenerative Brake Torque Requested motor (MG2) regenerative braking torque Min.: -4096.00 Nm, Max.: 4095.87 Nm While braking:
Varies depending on vehicle operation conditions
When regenerative braking is being performed, current flows from the motor (MG2) to charge the HV battery and braking torque is generated.

Electronically controlled brake system


Motor Regenerate Brake Execution Torque Motor (MG2) regenerative braking execution torque Min.: -4096.00 Nm, Max.: 4095.87 Nm While braking:
Varies depending on vehicle operation conditions
·

Hybrid vehicle control ECU

·

Hybrid vehicle transaxle assembly

·

Inverter with converter assembly


Generator Temperature Generator (MG1) temperature Min.: -40°C (-40°F), Max.: 215°C (419°F)
·

Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 25°C (77°F)

·

While driving: Varies depending on vehicle operating conditions


-
Generator Temperature Sensor Voltage Generator (MG1) temperature sensor voltage Min.: 0.00 V, Max.: 4.99 V - -
Generator Temperature just after IG ON Generator (MG1) temperature soon after power switch on (IG) Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Generator Maximum Temperature Maximum generator (MG1) temperature after power switch turned on (IG) in current trip Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Motor Temperature Motor (MG2) temperature Min.: -40°C (-40°F), Max.: 215°C (419°F)
·

Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 25°C (77°F)

·

While driving: Varies depending on vehicle operating conditions


-
Motor Temperature Sensor Voltage Motor (MG2) temperature sensor voltage Min.: 0.00 V, Max.: 4.99 V - -
Motor Temperature just after IG ON Motor (MG2) temperature soon after power switch on (IG) Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Motor Maximum Temperature Maximum motor (MG2) temperature after power switch turned on (IG) in current trip Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Generator Inverter Calculated Temperature Generator inverter calculated temperature Min.: 0°C (32°F), Max.: 150°C (302°F)
·

Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F)

·

While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F)


Inverter with converter assembly
Generator Inverter Calculated Temperature just after IG ON Generator inverter calculated temperature soon after power switch on (IG) Min.: 0°C (32°F), Max.: 150°C (302°F) - -
Generator Inverter Calculated Maximum Temperature Maximum generator inverter calculated temperature after power switch turned on (IG) in current trip Min.: 0°C (32°F), Max.: 150°C (302°F) - -
Motor Inverter Temperature Motor inverter temperature Min.: 8°C (46°F), Max.: 150°C (302°F)
·

Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F)

·

While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F)


Inverter with converter assembly
Motor Inverter Temperature just after IG ON Motor inverter temperature soon after power switch on (IG) Min.: 8°C (46°F), Max.: 150°C (302°F) - -
Motor Inverter Maximum Temperature Maximum motor inverter temperature after power switch turned on (IG) in current trip Min.: 8°C (46°F), Max.: 150°C (302°F) - -
Boosting Converter Temperature (Upper) Boost converter temperature (upper) Min.: 8°C (46°F), Max.: 150°C (302°F)
·

Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F)

·

While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F)


Inverter with converter assembly
Boosting Converter Temperature (Lower) Boost converter temperature (lower) Min.: 8°C (46°F), Max.: 150°C (302°F)
·

Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F)

·

While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F)


Inverter with converter assembly
Boosting Converter Temperature just after IG ON Boost converter temperature soon after power switch on (IG) Min.: 8°C (46°F), Max.: 150°C (302°F) - -
Boosting Converter Maximum Temperature Maximum converter temperature after power switch turned on (IG) in current trip Min.: 8°C (46°F), Max.: 150°C (302°F) - -
Generator Inverter Operation Request Generator inverter operation request Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement - -
Generator Inverter Fail Generator inverter stopped ON or OFF
·

Generator inverter stopped: ON

·

Normal: OFF


-
Generator Inverter Shutdown Status Generator inverter shutdown status Awake or Shutdown
·

Generator inverter shutdown: Shutdown

·

Normal: Awake


-
Motor Inverter Operation Request Motor inverter operation request Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement - -
Motor Inverter Fail Motor inverter stopped ON or OFF
·

Motor inverter stopped: ON

·

Normal: OFF


-
Motor Inverter Shutdown Status Motor inverter shutdown status Awake or Shutdown
·

Motor inverter shutdown: Shutdown

·

Normal: Awake


-
Boosting Converter Operation Request Boost converter operation request Normal / Boosting Stop / Upper Arm ON / Maximum Boosting / Output Torque / Upper Arm Lowering - -
Boosting Converter Fail Boost converter stopped ON or OFF
·

Boost converter stopped: ON

·

Normal: OFF


-
Boosting Converter Shutdown Status Boost converter shutdown status Awake or Shutdown
·

Boost converter shutdown: Shutdown

·

Normal: Awake


-
Generator Carrier Frequency Generator carrier frequency 0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode - -
Generator Control Mode Generator (MG1) control mode Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode
·

PWM: Sine Wave

·

Variable PWM: Overmodulation

·

Rectangular wave: Square Wave


-
Motor Carrier Frequency Motor (MG2) carrier frequency 0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode - -
Motor Control Mode Motor (MG2) control mode Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode
·

PWM: Sine Wave

·

Variable PWM: Overmodulation

·

Rectangular wave: Square Wave


-
Boosting Converter Carrier Frequency Boost converter signal carrier frequency 9.55 kHz / 9.13 kHz / 8.71 kHz / 8.29 kHz / 7.87 kHz / 7.45 kHz / 4.8 kHz - -
VL-Voltage before Boosting High voltage before it is boosted - Power switch on (READY):
Practically the same as the HV battery voltage
·

HV battery

·

Inverter with converter assembly


VH-Voltage after Boosting High voltage after it is boosted - Engine revving up with shift lever in P:
After boosted voltage to below approximately 600 V
Inverter with converter assembly
Boost Ratio Boost converter boost ratio Min.: 0.0%, Max.: 100.0% - Inverter with converter assembly
V Phase Generator Current V phase generator current Min.: -3276.8 A, Max.: 3276.7 A - -
W Phase Generator Current W phase generator current Min.: -3276.8 A, Max.: 3276.7 A - -
V Phase Motor Current V phase motor current Min.: -3276.8 A, Max.: 3276.7 A - -
W Phase Motor Current W phase motor current Min.: -3276.8 A, Max.: 3276.7 A - -
Inverter Coolant Water Temperature Inverter coolant temperature Min.: -40°C (-40°F), Max.: 110°C (230°F)
·

Cold start→Fully warmed up: Gradually rises

·

System operating normally: Controlled at 65°C (149°F) or less


·

Inverter with converter assembly

·

Inverter water pump assembly

·

Cooling fan system

·

Inverter cooling system


Inverter Water Pump Inverter water pump assembly status ON or OFF During Active Test:
ON
Active Test item [Activate the Inverter Water Pump] support data.
Inverter Water Pump Duty Ratio Inverter water pump motor driver request duty Min.: 0.00%, Max.: 100.00% Power switch on (READY):
40 to 85%
Hybrid vehicle control ECU
Inverter Water Pump Revolution Inverter water pump assembly speed Min.: 0 rpm, Max.: 15000 rpm Power switch on (READY):
1000 to 9300 rpm
When the inverter water pump assembly is not operating:
200 rpm or less
Overvoltage Input to Inverter Overvoltage detection into inverter ON or OFF
·

Overvoltage is detected into inverter: ON

·

Normal: OFF


-
Inverter Emergency Shutdown (Main CPU) Inverter emergency shutdown ON or OFF
·

Inverter emergency shutdown: ON

·

Normal: OFF


-
Inverter Emergency Shutdown (Sub CPU) Inverter emergency shutdown ON or OFF
·

Inverter emergency shutdown: ON

·

Normal: OFF


-
Overvoltage Input to Boosting Converter Overvoltage detection into boost converter ON or OFF
·

Overvoltage is detected into boost converter: ON

·

Normal: OFF


-
Hybrid Battery SOC HV battery state of charge
Primary calculated from charging and discharging amperage
Min.: 0.00%, Max.: 100.00% Constant:
0.00 to 100.00%
·

HV battery

·

Battery ECU assembly

·

Hybrid vehicle control ECU


Hybrid Battery SOC of Immediately after IG ON HV battery state of charge soon after power switch on (IG) Min.: 0.0%, Max.: 100.0% - -
Hybrid Battery Maximum SOC Maximum SOC after power switch turned on (IG) in current trip Min.: 0.0%, Max.: 100.0% - -
Hybrid Battery Minimum SOC Minimum SOC after power switch turned on (IG) in current trip Min.: 0.0%, Max.: 100.0% - -
Hybrid Battery Voltage HV battery voltage Min.: 0.00 V, Max.: 510.00 V Power switch on (READY):
150.0 to 300.0 V
·

HV battery

·

Battery ECU assembly

·

Hybrid vehicle control ECU


Hybrid Battery Current HV battery current Min.: -3276.8 A, Max.: 3276.7 A Power switch on (READY):
-200.0 to 200.0 A
·

HV battery

·

Power cable

·

Inverter with converter assembly

·

Battery current sensor


Hybrid Battery Current for Driving Control Hybrid battery current for driving control Min.: -327.68 A, Max.: 327.67 A -
·

Discharging amperage is indicated by a positive value

·

Charging amperage is indicated by a negative value


Hybrid Battery Cooling Fan Low Speed Request Battery cooling blower assembly Lo speed requested ON or OFF Constant:
ON or OFF
-
Short Wave Highest Value Level Waveform voltage level in abnormal insulation detection circuit in battery ECU assembly Not Judge / Normal / Insulation Lower LV2 / Insulation Lower LV3
·

Judgment not completed:

Not Judge

·

Normal:

Normal condition

·

Medium low level:

Insulation Lower LV2

·

Severe low level:

Insulation Lower LV3


High voltage circuit
Insulation Resistance Division Check Completion using MG Inv Insulation resistance division check completion using MG inverter Not Complete / Complete Decreased insulation resistance judgment for motor and generator inverter has completed:
Complete
After turning the power switch from on (READY) to off, compare the value of Data List item "Short Wave Highest Value Level" before and after the motor and generator inverter are shut down.
Insulation Resistance Division Check Completion using A/C Inv Insulation resistance division check completion using A/C inverter Not Complete / Complete Decreased insulation resistance judgment for the air conditioning inverter has completed:
Complete
Check the value of Data List item "Short Wave Highest Value Level" before and after the air conditioning inverter is shut down.
Insulation Resistance Division Check Completion using SMR Insulation resistance division check completion using SMR Not Complete / Complete Decreased insulation resistance judgment for the system main relays has completed:
Complete
Check the value of Data List item "Short Wave Highest Value Level" before and after the system main relays are turned off.
Short Wave Highest Value Availability just after MG Inv On/Off Short wave highest value availability just after MG inverter on/off No or Yes The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after the motor and generator inverter are turned on/off:
No
-
Short Wave Highest Value Availability just after A/C Inv On/Off Short wave highest value availability just after A/C inverter on/off No or Yes The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after air conditioning inverter turned on/off:
No
-
Short Wave Highest Value Availability just after SMR On/Off Short wave highest value availability just after SMR on/off No or Yes The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after system main relays turned on/off:
No
-
Immobiliser Communication Immobiliser communication line status ON or OFF
·

Power switch on (IG):

ON

·

Immobiliser communication line malfunction:

OFF


-
Permit Start by Immobiliser Status of starting permission by immobiliser (immobiliser to hybrid vehicle control ECU) No Judgment / OK / NG - -
Auxiliary Battery Voltage Auxiliary battery voltage Min.: 0.00 V, Max.: 16.00 V Always:
11.00 to 15.00 V
When power switch on (READY): approx. 12.5 to 15.0 V.
When power switch on (IG): same as auxiliary battery voltage (approx. 12 V).
If the voltage becomes 11 V or less when the power switch is on (READY), the hybrid vehicle control ECU stores inverter with converter assembly DTCs. If the voltage becomes 9.5 V or less, the power switch will not be able to be turned on (READY).
·

Auxiliary battery

·

Hybrid vehicle converter


Auxiliary Battery Current Auxiliary battery current Min.: -125.00 A, Max.: 124.99 A - -
Smoothed Value of Auxiliary Battery Temperature Smoothed value of auxiliary battery temperature Min.: -30.0°C (-22.0°F), Max.: 6513.5°C (11756.3°F) - -
Auxiliary Battery Voltage Low Times Auxiliary battery voltage low times Min.: 0, Max.: 255 - -
Auxiliary Battery Voltage at Low Voltage Checking Initiation Voltage of auxiliary battery voltage low judgment - - -
Auxiliary Battery Charging Integrated Current Cumulative battery charging integrated current value since vehicle was built Min.: 0.0 Ah, Max.: 429496729.5 Ah - -
Auxiliary Battery Discharging Integrated Current Cumulative battery discharging integrated current value since vehicle was built Min.: 0.0 Ah, Max.: 429496729.5 Ah - -
Auxiliary Battery Capacity after IG ON Auxiliary battery capacity after power switch on (IG) Min.: -128 Ah, Max.: 127 Ah - -
Auxiliary Battery Capacity after IG OFF Auxiliary battery capacity after power switch off Min.: -128 Ah, Max.: 127 Ah - -
Auxiliary Battery Status of Full Charge Auxiliary battery status when full charge Min.: 0.0 Ah, Max.: 127.5 Ah - -
Auxiliary Battery Charging Rate Accuracy Auxiliary battery charging rate accuracy Low / Middle / High / Disable - -
Auxiliary Battery Dark Current Auxiliary battery dark current Min.: 0 mA, Max.: 65535 mA - -
Auxiliary Battery Sensor Sleep Time Auxiliary battery sensor sleep time Min.: 0 h, Max.: 255 h - -
Integrated Ready ON Time Cumulative time power switch has been on (READY) since vehicle was built Min.: 0 hour, Max.: 65535 hour - -
Number of Long Term Leaving with IG OFF Number of times power switch not changed from off for long period of time (1440 hours (60 days)) Min.: 0, Max.: 255 - -
Auxiliary Battery Integrated Thermal Load Cumulative auxiliary battery thermal load since vehicle was built Min.: 0, Max.: 4294967295 - -
Total Distance Indicated after Long Term Leaving with IG OFF (1st) Cumulative distance before 1st long term power switch off period of time (1440 hours (60 days)) Min.: 0 km, Max: 131070 km - -
Total Distance Indicated after Long Term Leaving with IG OFF (2nd) Cumulative distance before 2nd long term power switch off period of time (1440 hours (60 days)) Min.: 0 km, Max: 131070 km - -
Total Distance Indicated after Long Term Leaving with IG OFF (3rd) Cumulative distance before 3rd long term power switch off period of time (1440 hours (60 days)) Min.: 0 km, Max: 131070 km - -
Time of Long Term Leaving with IG OFF (1st) Number of days of 1st long term power switch off period of time (1440 hours (60 days)) Min.: 0 day, Max.: 255 day - -
Time of Long Term Leaving with IG OFF (2nd) Number of days of 2nd long term power switch off period of time (1440 hours (60 days)) Min.: 0 day, Max.: 255 day - -
Time of Long Term Leaving with IG OFF (3rd) Number of days of 3rd long term power switch off period of time (1440 hours (60 days)) Min.: 0 day, Max.: 255 day - -
Auxiliary Battery Average Current during IG OFF 1 Trip before Average auxiliary battery current when power switch off 1 trip before Min.: -30.000 A, Max: 1.998 A - -
Auxiliary Battery Average Current during IG OFF 2 Trip before Average auxiliary battery current when power switch off 2 trip before Min.: -30.000 A, Max: 1.998 A - -
Auxiliary Battery Average Current during IG OFF 3 Trip before Average auxiliary battery current when power switch off 3 trip before Min.: -30.000 A, Max: 1.998 A - -
Auxiliary Battery Average Current during IG OFF 4 Trip before Average auxiliary battery current when power switch off 4 trip before Min.: -30.000 A, Max: 1.998 A - -
Auxiliary Battery Average Current during IG OFF 5 Trip before Average auxiliary battery current when power switch off 5 trip before Min.: -30.000 A, Max: 1.998 A - -
Total Distance Up to 1 Trip before Cumulative distance traveled 1 trip before Min.: 0 km, Max: 131070 km - -
Total Distance Up to 2 Trip before Cumulative distance traveled 2 trip before Min.: 0 km, Max: 131070 km - -
Total Distance Up to 3 Trip before Cumulative distance traveled 3 trip before Min.: 0 km, Max: 131070 km - -
Total Distance Up to 4 Trip before Cumulative distance traveled 4 trip before Min.: 0 km, Max: 131070 km - -
Total Distance Up to 5 Trip before Cumulative distance traveled 5 trip before Min.: 0 km, Max: 131070 km - -
IG OFF Time before 1 trip Number of days power switch was off 1 trip before Min.: 0 day, Max.: 255 day - -
IG OFF Time before 2 trip Number of days power switch was off 2 trip before Min.: 0 day, Max.: 255 day - -
IG OFF Time before 3 trip Number of days power switch was off 3 trip before Min.: 0 day, Max.: 255 day - -
IG OFF Time before 4 trip Number of days power switch was off 4 trip before Min.: 0 day, Max.: 255 day - -
IG OFF Time before 5 trip Number of days power switch was off 5 trip before Min.: 0 day, Max.: 255 day - -
IG ON Time Up to 1 trip before Time power switch was on (IG) 1 trip before Min.: 0 min, Max.: 510 min - -
IG ON Time Up to 2 trip before Time power switch was on (IG) 2 trip before Min.: 0 min, Max.: 510 min - -
IG ON Time Up to 3 trip before Time power switch was on (IG) 3 trip before Min.: 0 min, Max.: 510 min - -
IG ON Time Up to 4 trip before Time power switch was on (IG) 4 trip before Min.: 0 min, Max.: 510 min - -
IG ON Time Up to 5 trip before Time power switch was on (IG) 5 trip before Min.: 0 min, Max.: 510 min - -
Ready ON Time Up to 1 trip before Time power switch was on (READY) 1 trip before Min.: 0 min, Max.: 510 min - -
Ready ON Time Up to 2 trip before Time power switch was on (READY) 2 trip before Min.: 0 min, Max.: 510 min - -
Ready ON Time Up to 3 trip before Time power switch was on (READY) 3 trip before Min.: 0 min, Max.: 510 min - -
Ready ON Time Up to 4 trip before Time power switch was on (READY) 4 trip before Min.: 0 min, Max.: 510 min - -
Ready ON Time Up to 5 trip before Time power switch was on (READY) 5 trip before Min.: 0 min, Max.: 510 min - -
Power Feeding Electrical Using Status Usage state of power supplied from external power source charging Charge Sustaining Mode/Not PHV / Charge Depleting Mode / Charge Increasing Mode / Ready OFF - -


ACTIVE TEST


Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

NOTICE:
·

It is necessary to use caution, because if the tester DLC connector becomes disconnected or if a communication error occurs during an Active Test, the vehicle could become inoperative (the READY indicator may go off).

·

After performing the Active Test, turn the power switch off before proceeding to the next step.



a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Hybrid Control / Active Test.


e.

According to the display on the GTS perform the appropriate Active Test.

Powertrain > Hybrid Control > Active Test
Tester Display Measurement Item Control Range Restrict Condition Diagnostic Note
Hybrid Battery Charge To charge the HV battery using the THS charger ON / OFF Power switch on (IG), shift lever in P, other Active Tests not being performed, auxiliary battery voltage is 9.5 V or more and DTCs are not output
·

Test Details

Allows current to flow into the HV battery by operating the SMRs


·

When DTCs are memorized, complete the repairs of those DTCs and then clear the DTCs


Compression Test To crank the engine continuously in order to measure the compression ON / OFF Power switch on (IG), HV system normal, not in cranking mode, and other Active Tests not being done
·

Test Details

Allows the engine to continue cranking by activating generator (MG1) continuously



Activate the Inverter Water Pump To activate the inverter water pump assembly continuously ON Power switch on (IG), HV system normal, not in maintenance mode, and other Active Tests not being performed, auxiliary battery voltage is 9.5 V or more
·

Test Details

Before performing the Active Test of the inverter water pump assembly, check the coolant level.


Related Data List
-

Inverter Coolant Water Temperature

-

Inverter Water Pump

-

Inverter Water Pump Duty Ratio

-

Inverter Water Pump Revolution

-

Auxiliary Battery Voltage



Connect the TC and TE1 Batch display of warnings on combination meter assembly ON / OFF Power switch on (IG)
·

Test Details

TC terminal can be switched ON/OFF