Home › Engine / Hybrid System › 2ZR-FXE (HYBRID / BATTERY CONTROL) › MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY) › from 2019.09
RM32K0E _51 Engine / Hybrid System _083958 2ZR-FXE HYBRID / BATTERY CONTROL _0404409 MOTOR GENERATOR CONTROL SYSTEM(for LITHIUM-ION BATTERY) C

2ZR-FXE HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM(for LITHIUM-ION BATTERY)  P033500  Crankshaft Position Sensor "A"  P033531  Crankshaft Position Sensor "A" No Signal  


DESCRIPTION

If the crankshaft position signal pulse sent from the ECM via a direct line is abnormal, the motor generator control ECU (MG ECU) (built into the inverter with converter assembly) stores DTC P033500 or P033531.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P033500 Crankshaft Position Sensor "A" NE signal (crankshaft position sensor) is not input for 2 sec. or more while the engine is running*
(1 trip detection logic)
·

SFI system

·

Inverter with converter assembly

·

ECM

·

Wire harness or connector


Does not come on Master Warning:
Comes on
P033531 Crankshaft Position Sensor "A" No Signal NE signal (crankshaft position sensor) is not input for 2 sec. or more while the engine is running*
(1 trip detection logic)
·

SFI system

·

Inverter with converter assembly

·

ECM

·

Wire harness or connector


Does not come on Master Warning:
Comes on

HINT:

*: When this DTC is stored, vibration may occur when the engine is stopped.


Related Data List
DTC No. Data List
P033500
P033531
·

Crank Position (Hybrid control system)

·

Engine Speed (Hybrid control system)



CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Turn the power switch on (READY).

7.

With the vehicle stopped, move the shift lever to P.

8.

Depress the accelerator pedal to start the engine.

9.

Depress the accelerator pedal and maintain the engine speed at 1000 rpm or more for 5 seconds or more.

NOTICE:

As the state of charge of the HV battery may be low after driving in fail-safe mode, it will automatically be charged for 5 to 10 minutes with power switch on (READY) after repairs have been performed.


10.

Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

11.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




WIRING DIAGRAM

A394771E06
0.052,1.49 1.271,1.875 1.219,0.385 10 false Crankshaft Position Sensor 4.948,2.781 7.042,3.177 2.094,0.396 10 false Motor Generator Control ECU (Inverter with Converter Assembly) 2.031,1.125 2.271,1.344 0.24,0.219 10 false IC 2.99,0.906 3.385,1.094 0.396,0.188 10 false NEO 2.302,2.604 2.698,2.792 0.396,0.188 10 false ECM 1.208,2.167 1.604,2.354 0.396,0.188 10 false C63 1.573,2.156 1.969,2.344 0.396,0.188 10 false E1 1.26,1.99 1.656,2.177 0.396,0.188 10 false 59 3.438,1.042 3.833,1.229 0.396,0.188 10 false A38 3.469,0.854 3.865,1.042 0.396,0.188 10 false 30 4.656,0.927 4.917,1.125 0.26,0.198 10 false 17 4.656,2.115 5.052,2.302 0.396,0.188 10 false 24 4.927,0.938 5.323,1.125 0.396,0.188 10 false NE 4.927,2.229 5.323,2.417 0.396,0.188 10 false GND1 4.938,2.604 5.333,2.792 0.396,0.188 10 false C65 6.208,1 6.604,1.188 0.396,0.188 10 false 1MG 6.219,1.844 6.615,2.031 0.396,0.188 10 false 2MG

CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C56
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT (ENGINE)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Engine / Trouble Codes.


d.

Check for DTCs.

Powertrain > Engine > Trouble Codes
50001 372
Result:
Result Proceed to
SFI system DTCs are not output. A
Any of the following DTCs are also output. B


Relevant Diagnosis
P03352A Crankshaft Position Sensor "A" Signal Stuck in Range
P033531 Crankshaft Position Sensor "A" No Signal
P033562 Crankshaft Position Sensor "A" Signal Compare Failure


e.

Turn the power switch off.



A

2.CHECK DTC OUTPUT (MOTOR GENERATOR CONTROL)

B

2.CHECK DTC OUTPUT (MOTOR GENERATOR CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Motor Generator / Trouble Codes.


d.

Check for DTCs.

Powertrain > Motor Generator > Trouble Codes
50001 395
Result:
Result Proceed to
None of the following DTCs are output. A
Any of the following DTCs are also output. B


DTC No. Relevant Diagnosis
P06B01C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P06D61C Generator Control Module Offset Power Circuit Voltage Out of Range
P0A1B1F Generator Control Module Circuit Intermittent
P1C2B49 Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure
P1C2B1C Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range
P1CAD49 Drive Motor "A" Position Sensor Internal Electronic Failure
P1CB038 Drive Motor "A" Position Sensor REF Signal Frequency Incorrect
P313487 Communication Error from Drive Motor "A" to Generator Missing Message
P313483 Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect
P313486 Communication Error from Drive Motor "A" to Generator Signal Invalid

HINT:

P033500 or P033531 may be stored due to a malfunction which also causes the DTCs in the preceding table to be stored. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.



e.

Turn the power switch off.



A

3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A452348

Check the connection condition of the low voltage connectors of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and the connector for water and foreign matter.

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE

NOTICE:

Before disconnecting the connector, confirm that it is properly connected by checking that the claws of the lock levers are engaged and that the connector cannot be pulled off.


OK:

- The connector is connected securely.

- The terminals are not deformed and are connected securely.

- No water or foreign matter in the connector.


Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C


HINT:

When connecting the connector, connect it with the lock levers raised. Rotate each lock lever downward and make sure that the connector is securely connected. When a lock lever is fully lowered, a click will be heard as its claw engages. After the click is heard, pull up on the connector to confirm that it is securely connected.




A

4.CHECK CONNECTOR CONNECTION CONDITION (ECM CONNECTOR)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK CONNECTOR CONNECTION CONDITION (ECM CONNECTOR)
a.
A452349

Check the connector connections and contact pressure of the relevant terminals for the ECM connectors.

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE

NOTICE:

Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector cannot be pulled off.


OK:

The connectors are connected securely and there are no contact pressure problems.


HINT:

When connecting each connector, connect it with the lock lever raised. Rotate the lock lever downward and make sure that the connector is securely connected. When the lock lever is fully lowered, a click will be heard as its claw engages. After the click is heard, pull up on the connector to confirm that it is securely connected.



Result:
Proceed to
OK
NG



OK

5.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - ECM)

NG

CONNECT SECURELY

5.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - ECM)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the inverter with converter assembly connector.


c.

Disconnect the ECM connector.


d.

Connect the cable to the negative (-) auxiliary battery terminal.


e.

Turn the power switch on (IG).


f.
A377958C10
0.323,0.948 0.75,1.229 0.427,0.281 1.552,4.188 1.948,4.448 0.396,0.26 2.74,3.271 2.844,4.135 true 1.802,1.156 1.74,1.969 true 0.083,0.083 0.396,0.281 0.313,0.198 10 false *a 0.104,2.188 0.417,2.385 0.313,0.198 10 false *b 0.427,0.99 0.885,1.188 0.458,0.198 10 false C65 1.615,4.219 2.073,4.417 0.458,0.198 10 false A38 2.74,4.188 3.198,4.385 0.458,0.198 10 false NEO 1.667,2.01 1.979,2.208 0.313,0.198 10 false NE
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
*b Front view of wire harness connector
(to ECM)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
C65-17 (NE) - Body ground Power switch on (IG) Below 1 V


NOTICE:

Turning the power switch on (IG) with the inverter with converter assembly connector and ECM connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



g.

Turn the power switch off.


h.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):
Tester Connection Condition Specified Condition
C65-17 (NE) - A38-30 (NEO) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Condition Specified Condition
C65-17 (NE) or A38-30 (NEO) - Body ground and other terminals Power switch off 10 kΩ or higher



i.

Disconnect the cable from the negative (-) auxiliary battery terminal.


j.

Reconnect the ECM connector.


k.

Reconnect the inverter with converter assembly connector.


Result:
Proceed to
OK
NG



OK

6.CHECK ECM

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK ECM
a.

Disconnect the ECM connectors.


b.

Measure the resistance according to the value(s) in the table below.

A377956C30
2.51,0.51 2.906,0.76 0.396,0.25 5.24,0.531 5.635,0.781 0.396,0.25 1.01,1.26 1.01,2.135 true 4.833,1.313 4.833,2.125 true 0.083,0.094 0.396,0.292 0.313,0.198 10 false *a 2.594,0.542 3.052,0.74 0.458,0.198 10 false C63 5.323,0.563 5.781,0.76 0.458,0.198 10 false A38 4.708,2.188 5.167,2.385 0.458,0.198 10 false NEO 0.927,2.188 1.24,2.385 0.313,0.198 10 false E1
*a Component without harness connected
(ECM)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
A38-30 (NEO) - C63-59 (E1) Power switch off 10 kΩ or higher



c.

Reconnect the ECM connectors.


Result:
Proceed to
OK
NG



OK

NG