| *1 | Battery ECU assembly | - | - |
| *1 | Battery ECU assembly | - | - |
| Terminal No.
(Symbols) |
Wiring Color | Input/Output | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|---|
| z22-1 (CA2L) - z22-4 (GND) | W - G | IN/OUT | CAN communication line | Power switch on (IG) | Pulse generation
(Waveform 1) |
| z22-2 (CA1H) - z22-4 (GND) | B - G | IN/OUT | CAN communication line | Power switch on (IG) | Pulse generation
(Waveform 2) |
| z22-3 (CA1L) - z22-4 (GND) | LG - G | IN/OUT | CAN communication line | Power switch on (IG) | Pulse generation
(Waveform 2) |
| z22-4 (GND) - Body ground | G | Ground | Ground | Always | Below 1 Ω |
| z22-8 (AM) - z22-4 (GND) | Y - G | IN | Constant power source | Always | 11 to 14 V |
| z22-9 (CA2H) - z22-4 (GND) | R - G | IN/OUT | CAN communication line | Power switch on (IG) | Pulse generation
(Waveform 1) |
| z22-10 (GND1) - Body ground | GR | Ground | Ground | Always | Below 1 Ω |
| z22-12 (SI0) - z22-4 (GND) | P - G | OUT | Battery cooling blower operation signal | Cooling fans operating | Pulse generation
(Waveform 3) |
| Cooling fans not operating | 4.5 to 5.5 V | ||||
| z22-14 (FP0) - z22-4 (GND) | V - G | IN | Battery cooling blower monitor signal | Cooling fans operating | Pulse generation
(Waveform 4) |
| Cooling fans not operating | 0 Hz | ||||
| z22-16 (IGCT) - z22-4 (GND) | L - G | IN | Power source | Power switch on (IG) | 11 to 15.5 V |
| z23-24 (VIB) - z23-12 (GIB) | BR - L-W | OUT | Power source for battery current sensor | Power switch on (IG) | 4.5 to 5.5 V |
| z23-11 (IB1) - z23-12 (GIB) | GR - L-W | IN | Battery current sensor 1 | Power switch on (IG) | Approximately 2.2 V |
| z23-23 (IB0) - z23-12 (GIB) | V - L-W | IN | Battery current sensor 0 | Power switch on (IG) | Approximately 2.8 V |
| z23-16 (TC0) - z23-4 (GC0) | G - G | IN | Intake air temperature sensor | Power switch on (IG)
HV battery temperature: -40 to 90°C (-40 to 194°F) |
4.75(-40°C) to 0.46 V(90°C) |
| z23-22 (TB0) - z23-10 (GB0) | P - P | IN | Battery temperature sensor 0 | Power switch on (IG)
HV battery temperature: -40 to 90°C (-40 to 194°F) |
4.75(-40°C) to 0.46 V(90°C) |
| z23-21 (TB1) - z23-9 (GB1) | Y - Y | IN | Battery temperature sensor 1 | Power switch on (IG)
HV battery temperature: -40 to 90°C (-40 to 194°F) |
4.75(-40°C) to 0.46 V(90°C) |
| z23-20 (TB2) - z23-8 (GB2) | L - L | IN | Battery temperature sensor 2 | Power switch on (IG)
HV battery temperature: -40 to 90°C (-40 to 194°F) |
4.75(-40°C) to 0.46 V(90°C) |
| z23-19 (TB3) - z23-7 (GB3) | R - P-B | IN | Battery temperature sensor 3 | Power switch on (IG)
HV battery temperature: -40 to 90°C (-40 to 194°F) |
4.75(-40°C) to 0.46 V(90°C) |
| z23-18 (TB4) - z23-6 (GB4) | W - W-G | IN | Battery temperature sensor 4 | Power switch on (IG)
HV battery temperature: -40 to 90°C (-40 to 194°F) |
4.75(-40°C) to 0.46 V(90°C) |
| z23-17 (TB5) - z23-5 (GB5) | B - B-W | IN | Battery temperature sensor 5 | Power switch on (IG)
HV battery temperature: -40 to 90°C (-40 to 194°F) |
4.75(-40°C) to 0.46 V(90°C) |
| z20-16 (GA0) - z20-11 (VA1) | B - P-B | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-11 (VA1) - z20-6 (VA2) | P-B - L-W | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-6 (VA2) - z20-1 (VA3) | L-W - LG | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-1 (VA3) - z20-17 (VA4) | LG - B-W | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-17 (VA4) - z20-12 (VA5) | B-W - Y | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-12 (VA5) - z20-7 (VA6) | Y - G | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-7 (VA6) - z20-2 (VA7) | G - GR | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-2 (VA7) - z20-18 (VA8) | GR - V | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-18 (VA8) - z20-13 (VA9) | V - R | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-13 (VA9) - z20-8 (VA10) | R - L | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-8 (VA10) - z20-3 (VA11) | L - P | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-3 (VA11) - z20-19 (VA12) | P - BR | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-19 (VA12) - z20-14 (VA13) | BR - W | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-14 (VA13) - z20-9 (VA14) | W - B | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-9 (VA14) - z20-4 (VA15) | B - W-G | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-4 (VA15) - z20-20 (VA16) | W-G - L-W | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-20 (VA16) - z20-15 (VA17) | L-W - P-B | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-15 (VA17) - z20-10 (VA18) | P-B - B-W | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z20-10 (VA18) - z20-5 (VA19) | B-W - LG | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z21-13 (GA1) - z21-9 (VA20) | Y - G | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z21-9 (VA20) - z21-5 (VA21) | G - GR | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z21-5 (VA21) - z21-14 (VA22) | GR - V | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z21-14 (VA22) - z21-10 (VA23) | V - R | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z21-10 (VA23) - z21-15 (VA24) | R - L | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z21-15 (VA24) - z21-11 (VA25) | L - P | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z21-11 (VA25) - z21-16 (VA26) | P - BR | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z21-16 (VA26) - z21-12 (VA27) | BR - W | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z21-12 (VA27) - z21-8 (VA28) | W - B | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z15-5 (VAD) - z15-9 (VA29) | B - W | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z15-9 (VA29) - z15-13 (VA30) | W - BR | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z15-13 (VA30) - z15-10 (VA31) | BR - P | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z15-10 (VA31) - z15-14 (VA32) | P - L | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z15-14 (VA32) - z15-11 (VA33) | L - R | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z15-11 (VA33) - z15-15 (VA34) | R - V | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z15-15 (VA34) - z15-8 (VA35) | V - GR | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z15-8 (VA35) - z15-12 (VA36) | GR - G | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z15-12 (VA36) - z15-16 (VA37) | G - Y | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-1 (GA2) - z16-6 (VA38) | LG - B-W | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-6 (VA38) - z16-11 (VA39) | B-W - P-B | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-11 (VA39) - z16-16 (VA40) | P-B - L-W | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-16 (VA40) - z16-2 (VA41) | L-W - W-G | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-2 (VA41) - z16-7 (VA42) | W-G - B | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-7 (VA42) - z16-12 (VA43) | B -W | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-12 (VA43) - z16-17 (VA44) | W - BR | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-17 (VA44) - z16-3 (VA45) | BR - P | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-3 (VA45) - z16-8 (VA46) | P - L | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-8 (VA46) - z16-13 (VA47) | L - R | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-13 (VA47) - z16-18 (VA48) | R - V | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-18 (VA48) - z16-4 (VA49) | V -GR | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-4 (VA49) - z16-9 (VA50) | GR - G | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-9 (VA50) - z16-14 (VA51) | G - Y | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-14 (VA51) - z16-19 (VA52) | Y - B-W | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-19 (VA52) - z16-5 (VA53) | B-W - LG | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-5 (VA53) - z16-10 (VA54) | LG - L - W | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-10 (VA54) - z16-15 (VA55) | L-W - P-B | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
| z16-15 (VA55) - z16-20 (VA56) | P-B - B | IN | Hybrid Battery Cell Voltage | Always | 1.9 to 4.1 V |
Oscilloscope waveforms
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.
Waveform 1
| Item | Content |
|---|---|
| Terminal | CH1: z22-9 (CA2H) - z22-4 (GND)
CH2: z22-1 (CA2L) - z22-4 (GND) |
| Equipment Setting | 1 V/DIV., 50 μs/DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 2
| Item | Content |
|---|---|
| Terminal | CH1: z22-2 (CA1H) - z22-4 (GND)
CH2: z22-3 (CA1L) - z22-4 (GND) |
| Equipment Setting | 1 V/DIV., 50 μs/DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 3
| Item | Content |
|---|---|
| Terminal | z22-12 (SI0) - z22-4 (GND) |
| Equipment Setting | 10 V/DIV., 1 ms/DIV. |
| Condition | Battery cooling blower assembly operating (Active Test of cooling fan being performed) |
The wavelength will vary with the operating speed of the battery cooling blower assembly.
Waveform 4
| Item | Content |
|---|---|
| Terminal | z22-14 (FP0) - z22-4 (GND) |
| Equipment Setting | 2 V/DIV., 2 ms/DIV. |
| Condition | Battery cooling blower assembly operating (Active Test of cooling fan being performed) |
The wavelength will vary with the operating speed of the battery cooling blower assembly.