Home › Power Source / Network › M20A-FXS (BATTERY / CHARGING) › CHARGING SYSTEM › from 2019.09
RM32K0E _57 Power Source / Network _084047 M20A-FXS BATTERY / CHARGING _0404934 CHARGING SYSTEM U

M20A-FXS BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECU  


C338835C29
1.281,0.354 1.781,0.604 0.5,0.25 3.271,0.354 3.771,0.604 0.5,0.25 5.313,0.365 5.813,0.615 0.5,0.25 1.406,0.365 1.865,0.563 0.458,0.198 10 false A97 3.375,0.365 3.833,0.563 0.458,0.198 10 false F160 5.406,0.375 5.865,0.573 0.458,0.198 10 false F161 0.156,0.146 0.469,0.344 0.313,0.198 10 false *1
*1 Hybrid Vehicle Control ECU - -


HINT:

The standard normal voltage between each pair of hybrid vehicle control ECU terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the hybrid vehicle control ECU terminal locations.


Hybrid Vehicle Control ECU
Terminal No. (Symbol) Wiring Color Input/Output Terminal Description Condition Specified Condition
A97-4 (HMCH) - F161-3 (E1) B - W-B IN/OUT CAN Communication signal Power switch on (IG) Pulse generation
(Waveform 1)
A97-5 (MREL) - F161-3 (E1) BE - W-B OUT IGCT relay Power switch on (IG) 11 to 14 V
A97-8 (LIN3) - F161-3 (E1) Y - W-B IN/OUT LIN communication signal Power switch on (READY) Pulse generation
A97-14 (HMCL) - F161-3 (E1) W - W-B IN/OUT CAN Communication signal Power switch on (IG) Pulse generation
(Waveform 1)

a.

Oscilloscope waveforms

HINT:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


i.
A284438E06
2.969,1.198 3.427,1.396 0.458,0.198 10 GND 2.969,1.573 3.427,1.771 0.458,0.198 10 GND 0.396,0.646 0.854,0.844 0.458,0.198 10 CH1 0.396,1.229 0.854,1.427 0.458,0.198 10 CH2

Waveform 1 (CAN communication signal)

Item Content
Terminal CH1: A97-4 (HMCH) - F161-3 (E1)
CH2: A97-14 (HMCL) - F161-3 (E1)
Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).